Protection Functions; Installation And Adjustment - HOMCOM 823-047V70 Instruction Manual

Local air conditioners
Table of Contents

Advertisement

3. Up: press
the key to increase temperature and timing set value.
4. Down: press
5. Fan: press
the key to select high, medium and low wind speed output
circularly.
6. Timer: press
hours and the timing value is adjusted upwards or downwards by one hour.
7. Swing: Press
8. Press
the key to switch between Celsius and Fahrenheit.
9. Sleep Mode: Press
IV. Protection Functions
3.1 Frost Protection Function:
In cooling, if the temperature of the exhaust pipe is too low, the machine will
automatically enter protection status; if the temperature of the exhaust pipe rises to a
certain temperature, it can automatically revert to normal operation.
3.2 Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will
automatically sound an alarm, and the full water indicator will light up. At this point,
you need to move the drainage pipe connecting the machine or the water outlet to
sewer or other drainage area to empty the water (details see Drainage Instructions at
the end of this chapter). After the water is emptied, the machine will automatically
return to the original state.
3.3 Automatic Defrosting (heating models have this function):
The machine has automatic defrosting function: during defrosting, the motor does
not work and the compressor will continue to work.
3.4 Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting
protection function after the compressor is turned off.
V. Installation and Adjustment
1. Installation:
Warning: before using the mobile air conditioning, keep it upright for at least two hours.
The air conditioning can be easily moved in the room. In the moving process, ensure that
the air conditioning is in the upright position and the air conditioning should be placed on
a flat surface. Do not install and use the air conditioning in the bathroom or other humid
environments.
1.1 Install the heat pipe assembly (as shown in Figure 1): screw the heat pipe assembly
(exhaust fitting end) into the exhaust port on the rear panel (counterclockwise).
the key to reduce temperature and timing set value.
the key to set timing value. Timing value can be set with 1-24
the louver will swing up and down.
the key to turn on the sleep mode.
8