Danfoss DEVI Smart Installation Manual page 5

Intelligent electronic timer thermostat or timer switch with wi-fi connectivity and app control
Table of Contents

Advertisement

DEVIreg™ Smart
Ambient temperature
Frost protection
temperature*
Temperature range*
Sensor failure monitoring*
Timer functions
Cable speci cation max.
Ball pressure test tem-
perature
Pollution degree
Controller type
Software class
Storage temperature
Installation Guide
0 °C to 30 °C
5 °C to 9 °C (default 5 °C)
Room temperature: 5 °C to 35 °C.
Floor temperature: 5 °C to 45 °C.
Max. oor: 20 °C to 35 °C (if unrecover-
able seal is broken then up to 45 °C).
Min. oor: 10 °C to 35 °C, only with
combination of room and oor sensor.
The thermostat has a built-in
monitoring circuit, which will switch
o the heating if the sensor is
disconnected or short-circuited.
2 periods per day for DEVIweb™.
5 periods per day for DEVIsmart App.
All clock/date/schedule settings are
updated from the cloud.
Set-point resolution of timer is
30 minutes.
2
1x4 mm
75 °C
2 (domestic use)
1C
A
-20 °C to +65 °C
5

Advertisement