MQ Power WHISPERWATT DCA125SSIU4F Operation Manual page 62

Hide thumbs Also See for WHISPERWATT DCA125SSIU4F:
Table of Contents

Advertisement

5. Press the [SELECT] button (Figure 91) to enter the
"Escape Mode" menu.
FAULT DIAGNOSTICS
ABOUT UNIT
USER LOGIN
ESCAPE MODE
UP
Figure 91. Main Menu (Select Button)
6. Press the [REQUEST] button (Figure 92) to send
"Escape Mode Request" signal to ECM.
ESCAPE MODE REQUEST
EMERGENCY RESERVE ENGINE
RUN MAY BE POSSIBLE.
TO ATTEMPT ESCAPE MODE:
PRESS THE REQUEST SOFT KEY.
EXIT
Figure 92. Escape Mode (Request Button)
PAGE 62 — DCA125SSIU4F 60 HZ GENERATOR • OPERATION MANUAL — REV. #6 (05/12/22)
DOWN SELECT
[SELECT]
BUTTON
REQUEST
[REQUEST]
BUTTON
7. Place the Auto Start/Stop Switch (Figure 93) in the
"Off/Reset" position.
AUTO
OFF/RESET
(CENTER)
Figure 93. Auto Off/Reset Manual Switch
(Off/Reset Position)
8. Place the Auto Start/Stop Switch (Figure 94) in the
"Manual" position to start the engine.
AUTO
OFF/RESET
Figure 94. Auto-Off/Reset Manual Switch
(Manual Position)
9. The Escape Mode Timer (Figure 95) will appear on
the main screen. This timer displays the remaining
Escape Mode operation time.
SD IN
SPEED
18
1800
E
E
DEF
SCR TROUBLE-PURGE PROHIBITED
Figure 95. Escape Mode Timer
„ If ESCAPE MODE is temporarily suspended, it is not
necessary to return to the ESCAPE MODE screen and
press the [REQUEST] button. ESCAPE MODE operation
will be available until around 30 minutes after operation
has been ended.
„ Once the ESCAPE MODE timer reaches zero minutes,
the engine will stop since the ESCAPE MODE time has
expired. Please perform maintenance to return the unit
to proper operating condition.
„ If the unit returns to Warning Level 1 while ESCAPE
MODE is running, ESCAPE MODE will be cancelled,
the ESCAPE MODE timer display will close, and normal
operation will resume.
MAINTENANCE
MANUAL
MANUAL
CHECK
MIN.
F
HOURS
00018.2
F
SCR SYS ERR

Advertisement

Table of Contents
loading