MQ Power WHISPERWATT DCA125SSIU4F Operation Manual page 51

Hide thumbs Also See for WHISPERWATT DCA125SSIU4F:
Table of Contents

Advertisement

DRAINING THE CONTAINMENT TANK
1. This generator is equipped with an environmental
containment tank. Inspect this tank regularly.
2. If the tank becomes full with fluids, remove the drain
bolt (Figure 70), then allow the fluids to drain into a
suitable container.
Figure 70. Draining Containment Tank
DCA125SSIU4F 60 HZ GENERATOR • OPERATION MANUAL — REV. #6 (05/12/22) — PAGE 51
CLEANING INSIDE THE FUEL TANK
If necessary, drain the fuel inside the fuel tank completely.
Using a spray washer (Figure 71) wash out any deposits
or debris that have accumulated inside the fuel tank.
CONTAINMENT
DRAIN BOLT
FUEL TANK INSPECTION
In addition to cleaning the fuel tank, the following
components should be inspected for wear:
„ Rubber Suspension — Look for signs of wear or
deformity due to contact with oil. Replace the rubber
suspension if necessary.
„ Fuel Hoses — Inspect nylon and rubber hoses for signs
of wear, deterioration or hardening.
„ Fuel Tank Lining — Inspect the fuel tank lining for signs
of excessive amounts of oil or other foreign matter.
MAINTENANCE
Figure 71. Fuel Tank Cleaning
N K
T A
E L
F U

Advertisement

Table of Contents
loading