Features; Intended Use - Inca Metal Cutting DCF36-LIGHT Installation And Operating Instruction

Table of Contents

Advertisement

INSTALLATION CODES
This appliance is a Direct Vent appliance which draws all combustion air from outside the building
through an intake vent pipe.
Installation must conform to local codes. In the absence of local codes, installation must conform to
the National Fuel Gas Code ANSI Z223.1/NFPA 54, or the current Natural Gas and Propane
Installation Code CSA B149.1. The unit, when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National Electric Code ANSI/NFPA No.70
or with the current Canadian Electrical Code CSA C22.1. In the state of Massachusetts, this product
can only be installed by a licensed plumber or a licensed gas fitter. Failure to comply will void the
warranty.
This appliance has been certified for use with natural gas and propane.
This appliance is not for use with solid fuels.
CODES D'INSTALLATION
Cet appareil est un appareil à évent direct, qui attire tous l'air de combustion provenant de l'extérieur
du bâtiment par une entrée d'évent.
L'installation doit se conformer aux codes locaux. En l'absence de codes locaux, l'installation doit
être conforme au National Fuel Gas Code ANSI Z223.1/NFPA 54, ou le gaz naturel actuel et le Code
d'installation du propane CSA B149.1. L'unité, une fois installé, doit être électriquement à la terre
conformément aux codes locaux ou, en l'absence de codes locaux, avec le National Electric Code
ANSI / NFPA No.70 ou avec l'actuel Code canadien de l'électricité CSA C22.1
Cet appareil a été certifié pour une utilisation avec du gaz naturel et le propane.
Cet appareil n'est pas pour une utilisation avec des combustibles solides.

1.2 FEATURES

Ignition system:
Electronic pilot ignition system.
Remote * Optional*
SP1001H/LTH digital remote available as an extra
1.3 INTENDED USE / USAGE PROPOSÉ
This appliance is intended to be used as a zero clearance fireplace. This unit is certified for installation in a bedroom or a
bed sitting room where the maximum input is within 50 cubic feet per 1000 Btu/hr, (i.e. 900 cubic feet for E unit & 1600
cubic feet for H unit). In Canada all bedroom installations require the use of wall thermostats (note: thermostats are not
allowed in the United States).
Cet appareil est destiné à être utilisé comme un foyer à dégagement zéro. This unit is certified for installation in a
bedroom or a bed sitting room where the maximum input is within 50 cubic feet per 1000 Btu/hr, (i.e. 900 cubic feet for E
unit & 1600 cubic feet for H unit). In Canada all bedroom installations require the use of wall thermostats (note:
thermostats are not allowed in the United States).
Page 8 of 57