SIGMATEK S-DIAS DI 202 Instruction Manual

Digital input module with counter function

Advertisement

Quick Links

DI 202
S-DIAS Digital Input Module
with Counter Function
Instruction Manual
Date of creation: 09.10.2013
Version date: 26.07.2023
Article number: 20-006-202-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S-DIAS DI 202 and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGMATEK S-DIAS DI 202

  • Page 1 DI 202 S-DIAS Digital Input Module with Counter Function Instruction Manual Date of creation: 09.10.2013 Version date: 26.07.2023 Article number: 20-006-202-E...
  • Page 2 (print, photocopy, microfilm or in any other process) without the express permission. We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in the handbook and assumes no responsibility for damages that occur...
  • Page 3 16 digital inputs 4 digital inputs with counter function The S-DIAS DI 202 digital input module is equipped with 20 inputs and a +24 V signal for reading the signal states “0“ and “1“. To suppress noise in the signal lines, input filters are provided. In addition, digital inputs 1-4 have a counter function.
  • Page 4: Table Of Contents

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Contents Introduction ................5 Target Group/Purpose of this Operating Manual ...... 5 Important Reference Documentation ......... 5 Contents of Delivery ..............5 Basic Safety Directives ............6 Symbols Used ................6 Disclaimer ..................
  • Page 5 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Connector Layout ..............17 Status LEDs ................. 17 Applicable Connectors ............... 18 Label Field ................... 19 Wiring ..................20 Wiring Example ................20 Note ....................21 Assembly/Installation ............22 Check Contents of Delivery ............22 Mounting ..................
  • Page 6 DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. 16 Hardware Class DI202 ............29 16.1 Interfaces ..................30 16.1.1 Clients ....................30 16.1.2 Servers ....................31 16.1.3 Communication Interfaces ..............31 16.2 Example ..................32 Page 4 26.07.2023...
  • Page 7: Introduction

    General knowledge of automation technology is required. Further help and training information, as well as the appropriate accessories can be found on our website www.sigmatek-automation.com. Our support team is happily available to answer your questions. Please see our website for our hotline number and business hours.
  • Page 8: Basic Safety Directives

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Basic Safety Directives Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes: DANGER Danger indicates that death or serious injury will occur, if the specified measures are not taken.
  • Page 9 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 INFORMATION Information  Provides important information on the product, handling or relevant sections of the documentation, which require attention. 26.07.2023 Page 7...
  • Page 10: Disclaimer

    It does not guarantee properties under the warranty. Please thoroughly read the corresponding documents and this operating manual before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through, non-compliance with these instructions or applicable regulations.
  • Page 11: General Safety Directives

    Regarding the requirements for Safety and health connected to the use of machines, the manufacturer must perform a risk assessment in accordance with machine directives 2006/42/EG before introducing a machine to the market. Operate the unit with devices and accessories approved by SIGMATEK only. 26.07.2023 Page 9...
  • Page 12: Software/Training

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. CAUTION Handle the device with care and do not drop or let fall. Prevent foreign bodies and fluids from entering the device. The device must not be opened! Manipulez l’appareil avec précaution et ne le laissez pas tomber. Empêchez les corps étrangers et les liquides de pénétrer dans l’appareil.
  • Page 13: Standards And Directives

    • 2011/65/EU “Restricted use of certain hazardous substances in electrical and electronic equipment” (RoHS Directive) The EU Conformity Declarations are provided on the SIGMATEK website. See Products/Downloads or use the search function and the keyword “EU Declaration of Conformity”. 26.07.2023...
  • Page 14: Type Plate

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Type Plate HW: Hardware version SW: Software version Page 12 26.07.2023...
  • Page 15: Technical Data

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Technical Data Digital Input Specifications Number Input voltage typically +24 V maximum +30 V Signal level low: < +8 V high: > +14 V (up to HW version 2.10) Signal level low: <...
  • Page 16 DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Page 14 26.07.2023...
  • Page 17: Miscellaneous

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Miscellaneous Article number 20-006-202 Standard UL 508 (E247993) Approbations UL, cUL, CE, UKCA Environmental Conditions Storage temperature -20 ... +85 °C Environmental temperature 0 ... +55 °C Humidity 0-95 %, non-condensing Installation altitude above sea 0-2000 m without derating level...
  • Page 18: Mechanical Dimensions

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Mechanical Dimensions Page 16 26.07.2023...
  • Page 19: Connector Layout

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Connector Layout Status LEDs Module Status green module active no supply available BLINKING (5 Hz) no communication User yellow can be set from the application (e.g. the module LED can be set to blinking through the visualization so that the module is easily found in the control cabinet) BLINKING (2 Hz) BLINKING (4 Hz)
  • Page 20: Applicable Connectors

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Applicable Connectors Connectors: X1-X5: Connectors with spring terminals (included in delivery) The spring terminals are suitable connecting ultrasonically compacted (ultrasonically welded) strands. Connections: Stripping length/Sleeve length: 10 mm Plug-in direction: parallel to conductor axis or to PCB Conductor cross section, rigid: 0.2-1.5 mm Conductor cross section, flexible:...
  • Page 21: Label Field

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Label Field Manufacturer Weidmüller Type MF 10/5 CABUR MC NE WS Weidmüller article number 1854510000 Compatible printer Weidmüller Type Printjet Advanced 230V Weidmüller article number 1324380000 26.07.2023 Page 19...
  • Page 22: Wiring

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Wiring Wiring Example Page 20 26.07.2023...
  • Page 23: Note

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Note The input filters, which suppress noise signals, allow operation in harsh environmental conditions. A careful wiring method is also recommended to ensure error-free function. The following guidelines should be observed: •...
  • Page 24: Assembly/Installation

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Assembly/Installation Check Contents of Delivery Ensure that the contents of the delivery are complete and intact. See chapter 1.3 Contents of Delivery. INFORMATION On receipt and before initial use, check the device for damage. If the device is damaged, contact our customer service and do not install the device in your system.
  • Page 25: Mounting

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Mounting The S-DIAS modules are designed for installation into the control cabinet. To mount the modules a DIN-rail is required. The DIN rail must establish a conductive connection with the back wall of the control cabinet. The individual S-DIAS modules are mounted on the DIN rail as a block and secured with latches.
  • Page 26 DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. Recommended minimum distances of the S-DIAS modules to the surrounding components or control cabinet wall: a, b, c … distances in mm (inches) Page 24 26.07.2023...
  • Page 27: Addressing

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 10 Addressing Address Size Access Type Description Reset value (hex) (bytes) Memory Input register Bit 0 input 1 Bit 1 input 2 0000 000000 … Bit 19 input 20 Bit 20-23 reserved Counter mode register Bit 0...
  • Page 28: Supported Cycle Times

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. 11 Supported Cycle Times 11.1 Cycle Times below 1 ms (in µs) x= supported 11.2 Cycle Times equal to or higher than 1 ms (in ms) x= supported x= supported Page 26 26.07.2023...
  • Page 29: Transport/Storage

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 12 Transport/Storage INFORMATION This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! Temperature and humidity fluctuations may occur during transport.
  • Page 30: Maintenance

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. 14 Maintenance INFORMATION During maintenance as well as servicing, observe the safety instructions from chapter 2 Basic Safety Directives. 14.1 Service This product was constructed for low-maintenance operation. 14.2 Repair INFORMATION In the event of a defect/repair, send the device with a detailed error description to the address listed at the beginning of this document.
  • Page 31: Hardware Class Di202

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 16 Hardware Class DI202 Hardware Class DI202 for the S-DIAS DI202 digital input module This hardware class is used to control the DI 202 hardware module with 20 digital inputs and 4 counters. More information on the hardware can be found in the module documentation.
  • Page 32: Interfaces

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. 16.1 Interfaces 16.1.1 Clients The client must be connected to an S-DIAS port, an "SdiasOut"_[x]” server. SdiasIn Place The physical location of the hardware module is entered in this client. Up to 64 modules, 0 to 63, can be assigned.
  • Page 33: Servers

    S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 16.1.2 Servers ClassState This server shows the actual status of the hardware class. DeviceID The device ID of the hardware module is shown in this server. FPGAVersion FPGA version of the module in 16#XY (e.g. 16#10 = version 1.0). SerialNo The serial number of the hardware module is shown in this server.
  • Page 34: Example

    DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. 16.2 Example Page 32 26.07.2023...
  • Page 35 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. DI 202 Documentation Changes Change date Affected Chapter Note page(s) 24.10.2013 Input frequency 1-4 and counter frequency input 1-4 added 23.12.2013 3 Connector Layout Changed image 11.02.2014 3 Connector Layout Changed image 3.2 Applicable Connectors Connection capacity added, French notes added 4.1 Wiring Example Added wiring schematic...
  • Page 36 DI 202 S-DIAS DIGITAL INPUT MODULE WITH COUNTER F. 06.12.2022 1.4 Miscellaneous UKCA conformity 26.07.2023 Document General chapters added, design Page 34 26.07.2023...