5. CONFIGURABLE INPUTS

Configurable inputs have an assigned function ( Configurable
inputs - DEFAULT), which is modifiable in programming ( Confi-
gurable inputs - AVAILABLE SETTINGS). Some functions vary if the
Energy Saving is active (relative § Section).

CONNECTIONS

Only connect devices with a volt free contact to configurable inputs.
The contact of the device must be connected between the input
and GND.
I1, I2, I3, I4 (TERMINAL BOARD J21)
V +24 V " accessories power supply
I4 Configurable input I4
I3 Configurable input I3
G GND Accessories power supply negative and Common contacts
I2 Configurable input I2
I1 Configurable input I1
G GND Accessories power supply negative and Common contacts
V +24 V " accessories power supply
J21
S1 (TERMINAL BOARD J1), S2 (TERMINAL BOARD J4)
T TEST
G GND Power supply negative and Common contacts
S1 Configurable input S1
G GND Power supply negative and Common contacts
V +24 V " (accessories power supply)
J1
T TEST
G GND Power supply negative and Common contacts
S2 Configurable input S2
G GND Power supply negative and Common contacts
V +24 V " (accessories power supply)
J2
E1, E2 (TERMINAL BOARD J7)
E2 Configurable input
G GND Accessories power supply negative and Common contacts
J7
E1 Configurable input

PROGRAMMING

For the available options, see the table  Configurable inputs - AVAIL-
ABLE SETTINGS and the subsequent sections. The input is activated
according to how the contact logic is programmed:
NO = the input activates when the contact closes
NC = the input activates when the contact opens
- from Board:
Basic Programming for the inputs of terminal board J21. Advanced Programming for
the inputs of terminal boards J1, J4 and J7.
The default contact logic can only be modified via the SDK EVO. The test (
is only available for the inputs configured as Opening Safety, Closing Safety and
Safety STOP.
- from SDK EVO:
/PROGRAMMING/INPUTS/OUTPUTS ...
...INPUTS I1-I4 , S1-S2 , E1/E2 (select the input)
...FUNCTION (assign the function no...61)
...NO/NC (the contact logic must be programmed according to the type of contact
of the device)
...TEST (available for inputs configured as Safeties)
E1SL
 2 Configurable inputs - DEFAULT
Input
Default Programming
(terminal board)
I1
External OPENING (NO)
I2
Internal OPENING (NO)
(J21)
I3
KEY (NO)
I4
Automatic Opening (NO)
Closing Safety EXT (NC)
S1 (J1)
TEST enabled
Closing Safety INT (NC)
S2 (J4)
TEST enabled
E1
not enabled
(J7)
E2
not enabled
 3 Configurable inputs - AVAILABLE SETTINGS
from SDK EVO
input NOT enabled
EXTERNAL OPENING
INTERNAL OPENING
AUTOMATIC OPENING
SEMI-AUTOMATIC OPENING
PHARMACY OPEN (NOT for SF1400 and GBF1500)
KEY
PARTIAL OPEN (NOT for SF1400 and GBF1500)
CLOSING SAFETY (TEST available)
OPENING SAFETY (TEST available)
SAFETY STOP (TEST available)
EXTERNAL CLOSING SAFETY (TEST available)
INTERNAL CLOSING SAFETY (TEST available)
EMERGENCY OPENING
EMERGENCY OPENING with MEMORY
EMERGENCY STOP
EMERGENCY STOP with MEMORY
EMERGENCY CLOSING
EMERGENCY CLOSING with MEMORY
EMERGENCY BREAK OUT
TOTALLY OPEN
AUTOMATIC EXIT ONLY TOTAL
AUTOMATIC ENTRY ONLY TOTAL
NIGHT TOTAL
MANUAL
1F
2F
,
...)
AUTOMATIC TWO-DIRECTIONAL PARTIAL (NOT for SF1400 and GBF1500)
INTERLOCK TWO-DIRECTIONAL TOTAL
AUTO MANUAL TOTAL
TIMER
RESET
0.0
J24
J23
J25
-
F
USB
ERR
BAT1
BAT2
SIC _ OP
SIC _ CL
EMERG
OPEN
10
Board function:
(default)
C1
C2
C3
C4
P1
1F
P2
2F
E1
E2
J7
J26
DL11
J22
J18
J7
J8
J9
J4
J4
J21
J1
J1
J13
J21
532258 04 - Rev. E
1
(
)
4
(
)
10
(
)
7
(
)
24
(
)
Y
(
)
25
(
)
Y
(
)
no
(
)
no
(
)
from Board
no
1
(NO)
4
(NO)
7
(NO)
8
(NO)
9
(NO)
10
(NO)
11
(NO)
20
(NC)
21
(NC)
23
(NC)
24
(NC)
25
(NC)
30
(NC)
31
(NC)
32
(NC)
33
(NC)
34
(NC)
35
(NC)
37
(NC)
40
(NO)
41
(NO)
42
(NO)
43
(NO)
44
(NO)
45
(NO)
46
(NO)
47
(NO)
60
(NO)
61
(NO)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdk evoLk evoKs evo

Table of Contents