SUMMER WAVES
SAND FILTER PUMP
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
For answers to common questions, setup videos and
troubleshooting tips, please visit support.polygroupstore.com
or call Customer Service: +1 (888) 919-0070
DO NOT RETURN PRODUCT TO STORE
Should you encounter a problem with your Polygroup
be made directly to Polygroup
. For any setup and troubleshooting issues, please visit support.polygroupstore.com. Customer Service: +1 (888) 919-0070.
®
You may be asked to return all or part of the product for inspection and/or repair. Do not return any product to Polygroup
Authorization number.
DISTRIBUTED BY: Polygroup
Should you encounter any problems, contact Customer Service at +1 (888) 919-0070 from 8AM to 5PM MST, Monday-Friday.
FOR ABOVE GROUND SWIMMING POOLS
ST1100 (10") / ST1600 (12") models
Product, please DO NOT return the product to the place of purchase. All warranty claims must
®
Trading Limited Unit 606, 6th Floor, Fairmont House, No.8 Cotton Tree Drive, Central, Hong Kong
®
Extended operating days and hours during peak season requirements.
OWNER'S MANUAL
®
NOTE: For the
instructional video on
setting up the sand filter
pump and pairing it with
the pool, please visit
www.polygroupstore.com
To order parts and accessories,
please visit
www.polygroupstore.com
without a Return Merchandise
®
09C3A4CAN103
©2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUMMER WAVES ST1100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Polygroup SUMMER WAVES ST1100

  • Page 1 . For any setup and troubleshooting issues, please visit support.polygroupstore.com. Customer Service: +1 (888) 919-0070. ® You may be asked to return all or part of the product for inspection and/or repair. Do not return any product to Polygroup without a Return Merchandise ®...
  • Page 2: Table Of Contents

    6-port valve - Parts list & Setup........................19 ~ 21 ASME compliant suction fitting info ......................... 22 Limited Warranty Polygroup Trading Limited (hereinafter “Polygroup ”) makes products at the best quality we are able to offer. All Polygroup products ® ® ®...
  • Page 3: Warnings

    CUSTOMERS WHO PURCHASE POOLS MAY BE REQUIRED BY LOCAL OR STATE LAW TO INCUR ADDITIONAL EXPENSES WHEN INSTALLING A POOL, IN ORDER TO COMPLY WITH STATE OR LOCAL LAWS REGARDING FENCING AND OTHER SAFETY REQUIREMENTS. CUSTOMERS SHOULD CONTACT THEIR LOCAL BUILDING CODE ENFORCEMENT OFFICE FOR FURTHER DETAILS. POLYGROUP IS NOT RESPONSIBLE FOR ANY ADDITIONAL EXPENSES THAT YOU MAY INCUR.
  • Page 4 Turn on the pump for the recommended hours daily. If you are unsure of the time frames please refer to support.polygroupstore.com for the recommended Pump Operation Hours based on pool types and sizes. Clean and replace filter cartridge frequently. Replace only with a genuine Polygroup / Summer Waves Brand filter cartridge.
  • Page 5 OWNER’S MANUAL First Aid 1. Keep a working phone and a list of emergency numbers near the pool. 2. Become certified in cardiopulmonary resuscitation (CPR). In the event of an emergency, immediate use of CPR can make a lifesaving difference. Special Warning 1.
  • Page 6 ASME American Society of Mechanical Engineers Two Park Avenue, New York NY 10016-5990 Contact: 800-843-2763 (U.S. & Canada) 973-882-1170 (outside North America) www.asme.org NSPI National Spa and Pool Institute (see APSP) UL Underwriters Laboratories 333 Pfingsten Road,Northbrook IL 60062-2096 Contact: 877-854-3577 or 847-272-8800 www.ul.com NSF NSF International P.O.
  • Page 7 5. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC) “Swimming Pools, Fountains and Similar Installations” or its latest approved edition. 6. The ST Series Sand Filtration Systems are manufactured by Polygroup and ETL control number 4000608 and 4006317 - double insulated and grounded - ®...
  • Page 8 Sand Specifications: Fill the tank with #20 silica sand ONLY. You can purchase the sand from your local home improvement or building material stores. WARNING: Using the incorrect sand may damage the filtration system and will void the warranty. RETURN FITTING SET SUCTION FITTING...
  • Page 9: Setup Instructions

    OWNER’S MANUAL SETUP INSTRUCTIONS Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts. WARNING: CLIMBING HAZZARD! PLEASE PREVENT CHILDREN FROM CLIMBING ON THE FILTRATION SYSTEM TO GAIN ACCESS TO THE POOL. Tools required: Flat-blade screwdriver (not included) 1.
  • Page 10 6. With the Drain Valve of the Sand Tank pointing outwards, 5. Insert and push the Lock Pins all the way down to secure the Pump to the Sand Tank Base place the Sand Tank onto the Sand Tank Base PUSH Drain Valve ALIGN...
  • Page 11 OWNER’S MANUAL 9. Fill the tank with #20 silica sand ONLY. You can purchase the 10. Remove the Sand Guard and save for future use. sand from your local home improvement or building material stores. Slowly pour sand into the Sand Tank until the sand level is between the Min and Max marks on the Center Pipe Sand...
  • Page 12 12. Place the Clamp around the flange of the 6-Port Valve 13. Close the Clamp by pushing the two jaws as close together and Sand Tank as possible. IMPORTANT: Align the hinge on the Clamp with the ridge on the flange of the 6-Port Valve PUSH The hinge of Clamp aligned with the ridge of 6-Port Valve...
  • Page 13 OWNER’S MANUAL 17. Connect the Short Hose between the Pump Outlet and the 16. When the Clamp is tightened and no more turns can be 6-Port Valve Inlet. Tighten the Hose Clamps with a flat-blade made, flip and push the Cam Handle towards the Sand Tank to secure.
  • Page 14: Use Of Pump

    USE OF PUMP Before using the Pump IMPORTANT: 1. Make sure to press the pump power switch to OFF before plugging the GFCI Power Cord Set into a power outlet. Do NOT connect the Set to a timer device. 2. Always PRESS DOWN the 6-Port Valve Handle BEFORE switching handle positions.
  • Page 15 OWNER’S MANUAL USE OF PUMP 1. Make sure the pump is switched OFF. 2. Plug the GFCI Power Cord Set to a grounded receptacle at least 15 feet (4.5m) away from the pool. Press the RESET button to start the pump. 3.
  • Page 16: Pool Water Care

    PUMP MOTOR CARE IMPORTANT! This Sand Filter Pump is protected by a thermal switch, a safety device that stops the pump from running when it's overheated, to prevent pump damage and prolong service life. If your pump turns off automatically, it’s likely the pool water temperature is too high or the water flow through the pump is insufficient for cooling the pump down.
  • Page 17: Troubleshooting Guide

    OWNER’S MANUAL TROUBLESHOOTING GUIDE WARNING: TURN OFF THE PUMP AND UNPLUG THE POWER CORD BEFORE TROUBLESHOOTING THE FILTER PUMP. Problem Cause Solution A. The Pump not plugged in OR the GFCI A. The GFCI Set must be plugged into a grounded power outlet. Then Power Cord Set not activated press the RESET button to start the Pump.
  • Page 18: Replacement Parts Ordering Info

    REPLACEMENT PARTS ORDERING INFO ST1100 ST1600 ST1100 ST1600 Key# Description Key# Description PART # PART # PART # PART # P58PP2884A09 P58PP1782E09 P58284283W05 P58284283W05 Suction Fitting (SF) P582842838UN P582842838UN P58PP28848UN P58PP17828UN Sand Tank Base P582842837CN P582842837CN P58PP28847CN P58PP17827CN P58PF1510P01 P58PF1510P01 Sand Tank P58000001W05 P58000000W05...
  • Page 19 OWNER’S MANUAL 6-PORT VALVE PARTS LIST Wrench Locking Ring Valve Handle Valve Gasket Top Cover O-Ring Pressure Gauge Drain Indicator Valve Housing Drain Indicator Gasket Valve Grate Gasket...
  • Page 20 6-PORT VALVE SETUP 1. Using the Wrench, twist counterclockwise to loosen and remove the Locking Ring. 2. Fit the Gasket in place. 3. Insert the Top Cover O-Ring into the groove of the Valve Housing. Top Cover O-Ring Valve Gasket Valve Housing...
  • Page 21 OWNER’S MANUAL 4. Insert the Valve Handle into the Valve Housing. Make sure that the key aligns with the keyway. 5. Place the Locking Ring over the Valve Housing. 6. Tighten the Locking Ring with the Wrench. Locking Ring...
  • Page 22: Asme Compliant Suction Fitting Info

    ASME COMPLIANT SUCTION FITTING INFORMATION PSF-100A and PSF-100B Suction Outlet Fitting (For Aboveground Pool) 1. PSF-100A and PSF-100B Suction Outlet Fitting are certified by IAPMO in accordance with the ASME/ANSI/APSP/ICC-16 2011 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. 2.
  • Page 23 : NE RETOURNEZ PAS L’ARTICLE www.polygroupstore.com AU DÉTAILLANT Si vous venez à rencontrer un problème avec votreproduit Polygroup , nous vous prionsdene pas retourner le produit au lieu d’achat. Toute réclamation sous ® garantie doit être soumise directement à Polygroup .
  • Page 24 ® ® ® ont été inspectés pour s'assurer qu’ils sont exempts de tout vice de matière et de fabrication avant de quitter l’usine. Polygroup offre une ® garantie de 180 jours à compter de la date d’achat pour la réparation ou le remplacement des produits de piscine. Les clauses de la présente garantie limitée peuvent être invoquées uniquement par l’acquéreur initial.
  • Page 25 LORS DE L’INSTALLATION D’UNE PISCINE POUR ÊTRE CONFORMES AUX LOIS NATIONALES ET LOCALES RELATIVES AU CLÔTURAGE ET À D’AUTRES EXIGENCES DE SÉCURITÉ. LES CLIENTS DOIVENT CONTACTER L’AGENCE LOCALE CHARGÉE DE L’APPLICATION DU CODE DE LA CONSTRUCTION POUR PLUS DE DÉTAILS. POLYGROUP NE PEUT ÊTRE TENU RESPONSABLE DES FRAIS SUPPLÉMENTAIRES QUE VOUS POURRIEZ ENGAGER.
  • Page 26 Lavez et remplacez fréquemment la cartouche filtrante. Remplacez-la exclusivement par une cartouche filtrante d'origine de la marque Polygroup / Summer ®...
  • Page 27 MANUEL DE L'UTILISATEUR 3. Placez les meubles (par exemple les tables et les chaises) loin de la piscine de manière à ce que les enfants ne puissent pas monter pour avoir accès à la piscine. Risque de choc electrique 1. Gardez tous les fils électriques, radios, haut-parleurs et autres appareils électriques à l’écart de la piscine. 2.
  • Page 28 APSP Association of Pool & Spa Professionals (formerly National Spa and Pool Institute) 2111 Eisenhower Avenue, Suite 500 Alexandria VA 22314-4679 Contact : 703 838-0083 www.apsp.org ASME American Society of Mechanical Engineers Two Park Avenue, New York NY 10016-5990 Contact : 800 843-2763 (États-Unis et Canada) ou 973 882-1170 (hors de l’Amérique du Nord) www.asme.org NSPI National Spa and Pool Institute (see APSP) UL Underwriters Laboratories...
  • Page 29 5. Tous les composants électriques doivent être installés conformément à l'article 680 du Code national de l'électricité (NEC) « Piscines, fontaines et installations similaires » ou à sa dernière édition approuvée. 6. Les pompes sont fabriquées par Polygroup et ETL. Numéros de contrôle : 4000608 et 4006317. Pompes munies d'une double isolation exigeant une mise à la ®...
  • Page 30 Spécifications du sable : Remplir le réservoir de sable siliceux no.20 UNIQUEMENT. Vous pouvez acheter le sable au magasin de rénovation ou de matériaux de construction le plus près de chez vous. AVERTISSEMENT : utiliser un sable inapproprié peut endommager le système de filtration et annulera votre garantie. RACCORD DE RETOUR D'EAU RACCORD DE SUCCION...
  • Page 31: Instructions D'assemblage

    MANUEL DE L'UTILISATEUR INSTRUCTIONS D’ASSEMBLAGE Avant d'assembler ce produit, prenez quelques minutes pour vérifier le contenu de l'emballage et vous familiariser avec toutes les pièces. AVERTISSEMENT : GRIMPAGE DANGEREUX ! VEUILLEZ EMPÊCHER LES ENFANTS DE GRIMPER SUR LE SYSTÈME DE FILTRATION POUR ALLER DANS LA PISCINE.
  • Page 32 6. En ayant le robinet de vidange du réservoir de sable 2 orienté vers 5. Insérer et pousser les goujons de verrouillage tout au fond l'extérieur, placez le réservoir de sable 2 sur la base du réservoir pour fixer la pompe à...
  • Page 33 MANUEL DE L'UTILISATEUR 9. Ne remplir le réservoir qu’avec du sable siliceux nº 20. Vous 10. Retirez le garde de sable 6 et conservez-le pour toute pouvez vous en procurer dans centre de rénovations ou chez un utilisation ultérieure. détaillant de matériel de construction près de chez vous. Versez doucement le sable dans le réservoir 2 jusqu'à...
  • Page 34 13. Fermer la bride 7 en poussant les deux bras les plus près possible. 12. Placer la bride 7 autour de la semelle de la vanne à 6 voies et du réservoir de sable 2. IMPORTANT : aligner la penture de la pince 7 avec l'arête de la bride sur la valve à...
  • Page 35 MANUEL DE L'UTILISATEUR 16. Une fois que la bride 7 est serrée et qu’aucun autre tour n’est 17. Branchez le tuyau court entre la sortie de la pompe et l'entrée possible, retourner et pousser le levier excentrique vers le de la soupape à 6 voies. Serrez le Collier de serrage de tuyau réservoir de sable 2 pour l’attacher.
  • Page 36: Utilisation De La Pompe

    UTILISATION DE LA POMPE Avant d’utiliser la pompe IMPORTANT : 1. S’assurer d’appuyer sur l’interrupteur de la pompe (en position « OFF ») avant de brancher ensemble de cordon d’alimentation GFCI dans une prise électrique. NE PAS brancher l’ensemble à un dispositif de minuterie. 2.
  • Page 37 MANUEL DE L'UTILISATEUR UTILISATION DE LA POMPE 1. S’assurer que la pompe n’a pas été mise en marche. 2. Brancher ensemble de cordon d’alimentation GFCI à une prise à la terre au moins 15 pieds (4,5 m) à l’écart de la piscine. Appuyer sur le bouton RESET («...
  • Page 38: Entretien Du Moteur De La Pompe Et De La Pompe

    NE JAMAIS laisser tomber des morceaux ou des pastilles de produits chimiques dans la piscine — faire ainsi peut présenter un danger pour les nageurs ou endommager la toile de votre piscine. 3. Nettoyer votre piscine régulièrement à l’aide d’un aspirateur alimenté par un tuyau d’arrosage de Polygroup ou tout autre détaillant de fournitures de piscine.
  • Page 39: Guide De Dépannage

    MANUEL DE L'UTILISATEUR GUIDE DE DÉPANNAGE AVERTISSEMENT : ÉTEINDRE LA POMPE ET DÉBRANCHER LE CORDON D'ALIMENTATION AVANT D’EFFECTUER UN ENTRETIEN DE LA POMPE DE FILTRAGE. Problème Cause Solution A. L’ensemble de cordon d’alimentation GFCI doit être branché dans une prise de courant mise à A.
  • Page 40: Renseignements Relatifs Aux Commandes De Pièces De Rechange

    RENSEIGNEMENTS RELATIFS AUX COMMANDES DE PIÈCES DE RECHANGE ST1100 ST1600 ST1100 ST1600 Description Description Touche# Touche# PIÈCE # PIÈCE # PIÈCE # PIÈCE # P58PP2884A09 P58PP1782E09 P58284283W05 P58284283W05 Raccord de succion (SF) P582842838UN P582842838UN P58PP28848UN P58PP17828UN Base du réservoir de sable P582842837CN P582842837CN P58PP28847CN...
  • Page 41 MANUEL DE L'UTILISATEUR LISTE DES PIÈCES DE LA VALVE À 6 PORTS Clé Écrou de serrage Poignée de la vanne Joint de la valve Joint torique du couvercle supérieur Indicateur de pression Indicateur de vidange Boîtier de la vanne Joint indicateur de vidange Grille de la valve Joint...
  • Page 42 INSTALLATION DE LA VALVE À 6 PORTS 1. À l’aide de la clé, faire tourner dans le sens inverse des aiguilles d’une montre pour desserrer et enlever l’écrou de serrage. 2. Faire rentrer le joint. 3. Insérer le joint torique du couvercle supérieur dans la rainure du boîtier de la vanne.
  • Page 43 MANUEL DE L'UTILISATEUR 4. Insérer la poignée de la vanne dans le boîtier de la vanne. S’assurer que la clavette s’aligne avec la rainure de clavette. 5. Placer l’écrou de serrage par-dessus le boîtier de la vanne. 6. Serrer l’écrou de serrage à l’aide de la clé. Écrou de serrage...
  • Page 44: Info Sur Le Raccord D'aspiration Conforme À La Norme Asme

    INFO SUR LE RACCORD D'ASPIRATION CONFORME À LA NORME ASME Dispositifs D’aspiration PSF-100A et PSF-100B (Pour Piscine Hors Sol) 1. Les orifices d’aspiration PSF-100A et PSF-100B sont certifiés par IAPMO en accordance avec la norme ASME/ANSI/APSP/ICC-16 2011 sur les Dispositifs d’Aspiration pour utilisation dans les piscines, les pataugeoires, les cuves thermales et les bains tourbillon.

Table of Contents