Commissioning
6.3

Switching on and switching off the sauna control

Read the operating manual and the safety instructions thoroughly and follow them be-
fore switching on.
→ See the sauna control operating instructions.
6.4
Functional test of the sauna control device and the electrical consum-
ers
24
Check the safety OFF. For this purpose disconnect the STB circuit directly on the
oven sensor during the sauna operation. The heating system must switch off auto-
matically. The corresponding message is displayed on the display.
Check the oven sensor. For this purpose disconnect the oven sensor circuit directly
on the oven sensor during the sauna operation. The heating system must switch off
automatically. The corresponding message is displayed on the display.
For the available bathing options "Sauna", "Sauna with humidity" and "Infrared",
check whether the phases L1, L2 and L3 have been connected to the appropriate
terminals (see circuit diagram).
Check the electrical consumers like the cabin light, cleaning light and fans. It must be
possible to switch on and switch off the electrical consumers through the corre-
sponding operating keys on the sauna control or the operating control.
Check the rotating direction of the fan.
Check the function of the electrical consumers, which are connected to the optional
inputs and outputs.
NOTE!
Operation of a standard oven:
In case of standard oven, the phases W, V and U are switched off one
after the other just before reaching the set temperature. While reheat-
ing, the phases U, V and W are switched on one after the other.
NOTE!
Bathing option "Sauna with humidity ":
In case of the bathing option "Sauna with humidity ", the phase W is
generally not activated for the heating system. Through the phase
VERD/Wb, the evaporator is activated. After this bathing option has
ended, the drying program starts automatically (
al). With the drying program the phase W is activated again for the ov-
en.
see operating manu-
Installation instructions