2.3

Voltage and switching capacity - electrical load

Designation
Nominal Voltage
Oven
1)
Evaporator
2)
Infrared
PS1 (FLE-STB)
Fan
Cabin Light
Cleaning Light
Table 3: Technical data – voltages and switching capacity consumer
1) Only in controls with the bathing option "Sauna with humidity"
2) Only in controls with the bathing option "Infrared"
2.4

If the sauna control device is installed in the technical room

If the sauna
The control device can be installed directly on the outer side of the cabin or at another
control device
location, however not within the cabin. If the installation is not done directly on the outer
is not directly
wall of the cabin then the following points should be noted:
installed on the
outer wall of the
cabin
Installation instructions
Value
400 V 3 N ~ 50Hz
3x 230 V~ max. 3x 3 kW (AC1) / 3x 0,55kW (AC3) / 3x 0,75kW (AC15)
230 V~ max. 3 kW (Inrush current max. 30A for 5ms)
230 V~ max. 3 kW (Inrush current max. 120A for 5ms)
For full-spectrum emitters max. 1,5kW
230 V~ max. 60 W (Inrush current max. 30A for 5ms)
230 V~ max. 15W...120 W (Inrush current max. 10A for 5ms)
230 V~ max. 15W...120 W (Inrush current max. 10A for 5ms)
230 V~ max. 120 W (Inrush current max. 10A for 5ms)
NOTE!
FASEL additionally offers a extension power unit for loads of 9 kW, 18
kW and 24 kW.
Lay the signal cables separately from the power line.
Do not lay the signal cables parallel to the power line.
Install a distribution box for the signal lines and another one for the power lines as
per Figure 1
Note EN 60335-2-53 for remote start
(Inrush current max. 30A for 5ms)
Technical Data