Installation
Installation
4
4.1
Installation of sauna control unit
Installation
The sauna control device should be installed sideways, above and below at a distance
of at least 5 cm from the walls or other equipment. There should be a distance of 10 cm
between other electrical devices.
The control unit and control panel must not be exposed to direct sunlight or rain.
The sauna control device must be mounted on a closed surface (no grid structure) so
that no electrical parts can be touched through the openings in the rear panel.
The control unit must be mounted so that it is at any time accessible! (e.g. for service,
wear parts, fuses, etc.)
12
ATTENTION!
Note ESD protection!
Do not touch on electrical parts because of ESD protection reasons.
When assembling only touch the circuit board at the plastic case or at
the edge of the board.
Also only touch the connection cable to the circuit board, on the con-
nector. Thereby do not touch the contact surfaces.
Therefore:
– Take appropriate protections.
Touch a grounded piece of metal as a minimum protection.
Installation instructions