Maintenance Schedule; Steam Cylinder Replacement - Vapac VIRTUOSO VE05-1P Installation And Operating Manual

Electrode boiler humidifier
Table of Contents

Advertisement

Maintenance

Maintenance schedule

Before commencing, turn off the
water supply, drain the cylinder,
switch off the main electricity
supply and allow the cylinder(s) to
cool.
Never leave water in the steam
cylinder when the appliance is not
in use; always drain it fully.
Always consult your distributor at
MS
the slightest doubt.
The unit will operate with a minimum
of maintenance. It is recommended that
maintenance is carried out at least once a year
by a suitably qualified person. More frequent
servicing may be required dependent upon the
environmental circumstances where the unit
is installed. Regular inspection is necessary,
especially in dirty areas, to assess the servicing
frequency.
The following procedures should be carried out
at least once each year:-
• Generally clean the exterior of the unit using
a damp cloth.
• Repair any damage to the unit.
• Carry out cylinder exchange (may be
required more frequently).
• Inspect water feed and clean or replace
the feed valve inlet strainer (see page 42) if
found necessary.
• Inspect condensate drain and replace pump
if necessary.
• Inspect steam hoses for cracks and correct
attachment to the unit. Repair any damage
found / replace.
• Inspect pipework connections and water
hoses and repair any damage found /
replace.
• Inspect all cables and electrical connections
for tightness and security.
Page No 48 of 80
Vapac, Virtuoso VE Humidifier, Installation Manual, EN 2024-01, D301474 Iss 0

Steam cylinder replacement

The water hardness and the humidity demand
on site will determine the effective life of a
steam cylinder. Units located in areas with
naturally soft water will experience longer
cylinder life. With hard water, a more frequent
exchange of cylinders must be expected.
The cylinder selection chart given on page 33
previously details the cylinders required for each
model based on soft, normal and hard water
hardness.
Scaling up of the Vapac steam cylinder is normal
and is outside the Vapac warranty
Cylinder full sensor cap
Electrode cap removed
Fig 15 - steam cylinder showing electrode caps
To exchange a steam cylinder:-
1. With the power connected to the unit,
manually drain the unit by pressing and
holding down the I/O/II switch on the fascia
of the unit in the "II" (Drain) position until
the cylinder has fully drained.
.