HIKVISION DS-2XS6A87G1-LS/4G User Manual page 102

Table of Contents

Advertisement

Before You Start
For certain device models, you need to enable the smart event function on VCA Resource page
first.
For the device supporting HEOP, go to VCA → APP to import and enable Smart Event.
Steps
1. Go to VCA → Smart Event → Intrusion Detection . For certain device models, you should go to
Configuration → Event → Smart Event → Intrusion Detection .
2. Check Enable.
3. Select a Region. For the detection region settings, refer to Draw Area .
4. Set the minimum size and the maximum size for the target to improve detection accuracy. Only
targets whose size are between the maximum size and the minimum size trigger the detection.
For the detail settings, refer to Set Size Filter .
5. Set rules.
Sensitivity
Sensitivity stands for the percentage of the body part of an acceptable target that enters the
predefined region. Sensitivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predefined region. ST stands for the complete target body. The higher the value of
sensitivity is, the more easily the alarm can be triggered.
Threshold
Threshold stands for the threshold for the time of the object loitering in the region. If the
time that one object stays exceeds the threshold, the alarm is triggered. The larger the value
of the threshold is, the longer the alarm triggering time is.
6. Optional: You can set the parameters of multiple areas by repeating the above steps.
7. For the arming schedule settings, refer to Set Arming Schedule . For the linkage method settings,
refer to Linkage Method Settings .
8. Click Save.