Customer service Phone: 1-877-671-7011 www.allegion.com/us Warnings and cautions WARNING Warnings indicate potentially hazardous conditions, which if not avoided or corrected, may cause death or serious injury. CAUTION Cautions indicate potentially hazardous conditions, which if not avoided or corrected, may cause minor or moderate injury.
Compliance and certifications FCC Statements FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Page 5
Compliance and certifications | FCC Statements FleX Module™ Listings FleX Module™ replacement on page 18 for more information. Î Module Description Hardware Part Number Model FCC ID 47334317 47334317 XPB-47334317 8053B-47334317 Figure 3.1: FleX Module label location, tubular and mortise models Figure 3.2: FleX Module label location, exit trim models v •...
Allegion. This equipment should be installed and operated with a normally maintained separation distance of at least 20 cm between the radiator and your body.
Page 8
Compliance and certifications | Certifications Exit Trim Outside lever is normally locked. Exit Trim will not interfere with the operation of Panic Hardware. ANSI/BHMA Additional certifications UL10-C 3-hour standard ULC S104 3-hour A156.3- 2014 Grade 1 PROP 65 standard A156.25-2018 Locked REACH UL294 7th Edition performance levels: Destructive Attack- Level I;...
Operation Credentials Placement Credentials should be placed in the area shown. For best results, touch the credential to the icon. Security CAUTION Credentials must be controlled. Report lost or stolen credentials to the site administrator immediately. 11 • Schlage • XE360 User guide...
Operation | Functionality Functionality The XE360 Series is available with four locking functions which are adaptable in the field. B: button, I: indicator, D: deadbolt Function Tubular Mortise Exit Description Storeroom Lockset is normally secure. Inside lever always allows free egress. Valid toggle credentials on the exterior may be used to change to a passage or secured ...
Operation | Power Power Insert batteries as shown. Replace batteries yearly to ensure continuous operation, or as necessary after the low battery warning. Use standard alkaline batteries. Lithium batteries are not recommended as there is little warning before the battery voltage is Î...
Page 14
Operation | Power XE360-M/XE360-T Loosen the screw in the bottom of the battery cover. Slide the battery cover down and off. The screw will remain retained in the cover. Screw retained in cover. Remove the battery holder retainer. Remove the battery holder and disconnect the cable connector.
Operation | Key override Battery Life Mode Operation Lights Voltage range Est. days of operation Interior Exterior Normal Normal Functionality and Access Control — Access Control Status 6.2 V - > 4.7 V Low Battery- Normal Functionality and Delayed Access —...
Operation | General maintenance and security General maintenance and security Yearly maintenance should be performed to keep the lock in optimal condition. Follow these guidelines to optimize security. Replace batteries. Power on page 13 for more information. Î Check for battery leakage. Contact Customer service (pg iii) for guidance if battery leakage is observed.
Operation | Lock modes Lock modes Normal mode The open architecture design of the XE360 allows it to be managed by an access control system, or be integrated into popular physical access control and Proptech systems through our PACS Alliance program.
FleX Module™ replacement IMPORTANT: Prior to replacing the FleX Module, verify the lock model. See Lock models on page for more information. MAPP (pg 27) The lock model may also be identified in the Exit device models Delete the lock from the access control system. See the access control system documentation for more Î...
Page 19
FleX Module™ replacement | Exit device models Install the new board. Install the new retention key vertically, then rotate to horizontal to lock into place. Replace the battery holder. Perform a Factory default reset (FDR) on the lock. Factory default reset (FDR) on page 26.
FleX Module™ replacement | Tubular and mortise models Tubular and mortise models Delete the lock from the access control system. See the access control system documentation for more Î information. Remove covers. Screw retained in cover. Remove battery retainer and holder. Release retention key by turning to the vertical position.
Page 21
FleX Module™ replacement | Tubular and mortise models Remove the retention key. Remove the top bracket. Then, tilt the FleX Module back and pull up to remove. Install new board. Reinstall the bracket. Install the new retention key vertically, then rotate to horizontal to lock into place. 21 •...
Page 22
FleX Module™ replacement | Tubular and mortise models Reinstall the battery holder and retainer. Perform a Factory default reset (FDR) on the lock. Factory default reset (FDR) on page 26. Î 10. Power cycle the lock by removing and then replacing the batteries.
Rekeying Tubular and mortise Remove exterior assembly from door. alle.co/XE360 for installation instructions. Î Remove three (3) screws from the bottom plate. Tip the bottom plate out and down to remove. Remove the cylinder retainer. Push up on the cylinder through the cylinder hole and then tip the cylinder out to remove.
Rekeying | Exits Exits Remove exterior assembly from door. alle.co/XE360 for installation instructions. Î Remove eight (8) screws. Remove the backplate and spindle. Remove three (3) screws from the bottom plate. Tip the bottom plate out and down to remove. Remove the cylinder retainer.
Diagnostics Indicators Process Lights Beeps Function Device Action Exterior Interior Initialization green green Initialization success Initialization failure Normal operation green Valid credential presented Invalid credential presented (if "Blink Relock Secures clutch Interior LED" enabled) Invalid credential Office, storeroom, privacy presented, one-time access, out of time zone green Unlock with button...
Diagnostics | Factory default reset (FDR) Indicators Process Lights Beeps Function Device Action Exterior Interior Construction mode green fast Master credential created green fast User credential created solid green until Waiting for user credential timeout to be presented long long Construction mode timeout Factory default reset (FDR)
Diagnostics | Request for exit (REX) Request for exit (REX) To ensure the REX is working properly, follow these diagnostic steps: The lock must be in FDR mode before performing these steps. Î Steps Lights Beeps Interior Exterior Power lock and wait for the steady blue light.
Troubleshooting Problem Lights Beeps Cause Solution System appears to not — Batteries not inserted correctly Reinstall batteries. be powered when the Battery holder not fully inserted Verify that obstructions are battery pack/holder are removed and the battery holder connected with fresh slides fully into place.
Page 29
Troubleshooting | Problem Lights Beeps Cause Solution DPS not working- when blue (except — Verify the DPS functionality in Remove interior assembly and door closes in FDR mode) FDR mode- open to closed reconnect DPS wiring harnesses. Install DPS switch and wiring harness.
Page 30
Troubleshooting | Problem Lights Beeps Cause Solution Advertising- not starting — REX switch not functioning See Request for exit (REX), when lever rotated properly. page 27 Remove interior assembly and reconnect rex wiring harnesses. Order new interior assembly. Advertising- not —...
Page 31
About Allegion™ Allegion (NYSE: ALLE) is a global pioneer in seamless access, with leading brands like CISA , Interflex , LCN , Schlage , SimonsVoss and Von Duprin ® ® ® ® ® ® Focusing on security around the door and adjacent areas, Allegion secures people and assets with a range of solutions for homes, businesses, schools and institutions.
Need help?
Do you have a question about the SCHLAGE XE360 Series and is the answer not in the manual?
Questions and answers