If these conditions are not fulfilled, the air
volume is automatically switched to the
higher level.
The air volumes can be changed as follows.
In the example here, the air volume for level
3 is increased from 150 to 180 m
1. Press button "F" for approx. 3 seconds to
activate the settings menu.
2. Select the required parameter with the "+"
button (U1 = Level 1, U2 = Level 2, U3 =
Level 3). U4, U5 and U9 have no function
with the WRG 180 EC.
3. Press the "OK" button for 1 second to
display the value of the selected
parameter.
16
4. The value of the selected parameter can
3
/h:
5. The modified value can now be:
be changed with the "+" or "-" buttons.
A: saved;
B not saved;
C reset to factory setting.
A: Press and hold buttons "F" and "+"
(first "F", then "+") to save the
modified value. The value flashes
three times to confirm that it has been
saved. The display continues to show
this modified value.
Press button "OK", to return to
the settings menu. If required,
further values can be changed
now (see steps 2 to 5).