Download Print this page

SAF Integra User Manual page 92

Advertisement

INTEGRA/-S/-G/-GS User Manual
1) Select sensors – Allows choosing the sensor parameters to be displayed in the
performance log.
2) Select fields – Allows choosing the parameter fields to be displayed in the
performance log. "Minimum" and "Maximum" represent the minimum and maximum
values in the specified sensor log step, while "Average" displays the average value;
"Threshold seconds" will show the number amount of seconds in a chosen time
interval when the parameter exceeded minimum or maximum alarm thresholds; "No
data (s)" and "Not available (s)" show respectively the time when there was no data
of according parameter and it was not available.
3) Sensor log step – Allows choosing log step – 1, 15, or 60 minutes.
4) Indicates start and end date/time of period displayed and allows selecting a specific
period to show.
5) Period length – Indicates the length of the currently displayed period.
6) Log entries per page – Allows choosing 20, 50, or 100 entries per page for Paged
representation.
7) One page – Will display the performance log on a single page in a separate tab.
8) Paged – Will display the performance log divided into pages in a separate tab.
9) Download XML – Press to download the performance log in an extensible markup
language (.xml) file.
CLI commands
(Chapter 4: COMMAND LINE
log perf show
{1M|15M|60M} last
<1...1440> <sensor>
log perf show
{1M|15M|60M} time
<start_time> <end_time>
<sensor>
SAF Tehnika JSC
INTERFACE)
Use to show a specified number of last performance log
entries with the specified sensor log step.
Use to show entries for a certain time frame.
Following formats are supported: YYYY-MM-DD/hh:mm:ss;
MM-DD/hh:mm:ss; MM-DD/hh:mm; hh:mm:ss; hh:mm
WEB GUI
92