Page 1
User manual Integra Integra-S Integra-G Integra-GS VER 2.37 F W 3 .20 .1 9 SAF Tehnika JSC...
Page 2
INTEGRA/-S/-G/-GS User Manual OVERVIEW Proprietary notice The information presented in this guide is the property of SAF Tehnika, JSC. No part of this document may be reproduced or transmitted without proper permission from SAF Tehnika, JSC. The specifications or information contained in this document are subject to change without notice due to continuing introduction of design improvements.
Integra/Integra-G FODU: assembling mounting bracket and installing with an antenna on a pole ..................9 Disassembled mounting bracket and tools required for assembly .... 9 Changing the polarization of Integra/Integra-G FODU and antenna ..10 Assembly procedure ................12 Antenna alignment .................. 14 Integra-S/Integra-GS 15-42GHz* FODU: attaching to the antenna ....
Page 4
Changing the radio side .................. 140 Radio configuration – extra fields ..............141 Setting bandwidth to 60MHz ................. 142 Chapter 6: FUNCTIONAL DESCRIPTION Integra-G block diagram ................. 143 ACM (Adaptive Coding and Modulation) ............143 ATPC (Automatic Transmit Power Control) ..........147 SAF Tehnika JSC...
Page 5
MIB files ......................162 Chapter 8: INTERFACES RJ-45 port ......................163 SFP ports ......................164 USB port ......................164 RSSI LED ......................165 Integra-S/Integra-GS RSSI LED description ......... 166 RSSI/audio port ....................169 Grounding connection ..................171 Appendix A: TECHNICAL SPECIFICATION ABBREVIATIONS CONTACTS...
Labeling The label contains the following information (see samples in the picture below): Product model name (“SAF Integra-18”). The FODU model name example is: SAF Integra-18 for Integra 18GHz FODU, SAF Integra-GS-23 for Integra-GS 23GHz FODU, etc Product Number / Model Number (P/N or M/N) (D18B1R05LB): product/model number contains various information about the unit.
INTEGRA/-S/-G/-GS User Manual OVERVIEW The frequency range of subband B low side Integra 18 GHz FODU: The minimum available bandwidth is 1.75 MHz Inquire SAF representative for more information Microwave Radiation In April 1998, ICNIRP (International Commission on Non-Ionizing Radiation Protection) published its ´Guidelines for limiting exposure to time-varying electric, magnetic, and...
Personen im Frequenzbereich von 30 kHz bis 300 GHz; - ENV 50166-2, January 1995 (withdrawed in December 1999 by CENELEC) ´Human Exposure to Electromagnetic Fields (10 kHz – 300 GHz)´ Integra-G 24 GHz FCC & IC IDs Integra-G 24 GHz: FCC ID: W9Z-INTEGRA24...
12 Fixation plate 13 Side screw flange nuts 14 Grounding flange nut The numbers of the mounting bracket and Integra/Integra-G FODU parts in the next sections will be mentioned in square brackets [ ]. Changing the polarization of Integra/Integra-G FODU and antenna Tools required: 13mm (0.512”) wrench (comes in the...
Page 11
INTEGRA/-S/-G/-GS User Manual INSTALLATION Remove Integra/Integra-G FODU with an Using 13mm wrench remove indicated nuts antenna from the mounting bracket. and fixation plate [10, 11, 12, 13, 14]. The default polarization is vertical. Removed parts must be attached back with View of Integra/Integra-G FODU with a 90-degree offset (see above).
INTEGRA/-S/-G/-GS User Manual INSTALLATION Assembly procedure Tools required: 13mm (0.512”) wrench (comes in the package) Attach vertical alignment eye screw [3] to clamps for housing and pipe [5] using hex flange bolt [8] and Using a 13mm wrench slightly loosen three hex screw on one hex nut [7] and two hex flange nuts [6].
Page 13
20 N·m. Make sure that both horizontal and vertical Attach Integra/Integra-G FODU with the antenna to the alignment eye screws are turned to the mast mounting bracket so that side screws fit into the before attaching Integra/Integra-G FODU.
Integra/Integra-G FODU and two hex flange elevation eye screws, right side screw on bolts between both mounting bracket clamps Integra/Integra-G FODU, and hex flange bolt on for housing and pipe. azimuth angle indicator. For initial alignment make sure that elevation is...
Page 15
Integra/Integra-G FODU and two hex flange side screw on Integra FODU, and hex flange bolts between both mounting bracket clamps bolt on azimuth angle indicator with torsion for housing and pipe with torsion 20...25 N·m.
INSTALLATION Integra-S/Integra-GS 15-42GHz* FODU: attaching to the antenna Parts of Integra-S/Integra-GS FODU: 1 – O-ring; 2 – flange protecting sticker; 3 – wire handle; 4 – fixation clamps; 5 – grounding screws. Tools required: Size 5 Allen wrench Level (not supplied)
Page 17
Integra-S/Integra-GS. Verify polarization accuracy with a level, by Adjust polarization so that the interface ports placing it on the top edge of the Integra- are located at the lower side of the Integra- S/Integra-GS housing S/Integra-GS. Secure the position of Integra-S/Integra-GS by fully tightening both fixation clamps.
Integra-S/Integra-GS 6-13GHz* FODU: attaching to the antenna Integra-S/Integra-GS 6-13GHz* FODU features twisted polarization flange and the resulting signal polarization is determined by Interface on antenna/OMT. To change signal polarization, please rotate only the antenna interface, as the radio always remains in the vertical position.
Page 19
Make sure the O-ring is in place and the adapter flange fits Tighten bottom fixation clamps. into the Integra-S/Integra-GS transition flange socket. Note! The protective sticker should be removed before attaching the Integra-S/Integra-GS FODU to the antenna.
Page 20
INTEGRA/-S/-G/-GS User Manual INSTALLATION Use the air level to verify that Integra-S/Integra- Final view of assembled Integra-S/Integra-GS 6- GS FODU is properly leveled. Tighten all four 13GHz* 1+0 setup. fixation clamps properly. * Integra-S/Integra-GS 6U/6L/7/8/10/11/13 are separate FODU models If any further assistance is required please contact techsupport@saftehnika.com...
Level (not supplied) It is recommended to perform steps 1-2 on the ground. Attach Integra-S/Integra-GS 6-13GHz* FODU to the OMT using both upper clamps Integra- Prepare Integra-S/Integra-GS 6-13GHz* FODU S/Integra-GS 6-13GHz* FODU features twisted by loosening both bottom clamps (should not...
Page 22
FODUs, OMT, 6-13GHz* 2+0 setup. and antenna. * Integra-S/Integra-GS 6U/6L/7/8/10/11/13 are separate FODU models For connecting Integra-S/-GS 15-42GHz to an OMT, please follow Integra-S/Integra-GS 15-42GHz* the instructions in Chapter FODU: attaching to the antenna If any further assistance is required please contact techsupport@saftehnika.com...
INTEGRA/-S/-G/-GS User Manual INSTALLATION Connecting FO interface using fiber conduit kit Unscrew the cap of the SFP port (LAN2 or LAN3) that Fiber conduit kit. will be used and install an SFP module. Disassemble the conduit kit and put its parts in Push the FO cable from the LC connector side through the following sequence (left –...
INTEGRA/-S/-G/-GS User Manual INSTALLATION Integra-GS 6-13GHz* remote mount kit assembly Tools required: Size 5 Allen wrench 13mm (0.512”) wrench (not supplied) Assemble the mounting bracket using a 13mm wrench: Screw one hex flange nut [4] on each of the Attach waveguide transition flange to the mounting four threaded rods [3].
INTEGRA/-S/-G/-GS User Manual INSTALLATION Integra-GS 15-42GHz* remote mount kit assembly Tools required: Size 5 Allen wrench 13mm (0.512”) wrench (not supplied) Assemble Mounting Bracket using a 13mm wrench: Screw one hex flange nut [4] on each of the Attach the waveguide transition flange to the four threaded rods [3].
INSTALLATION Initial setup in the indoor environment Integra-S/Integra-GS FODUs can be interconnected using a test kit (available for purchase as an optional accessory). P/N is DxxTST01, where xx – frequency band, e.g. D11TST01 for 11GHz. The exception is 17 and 24GHz radios.
The Ethernet cable from the PoE injector should be connected to the RJ-45 port on Integra/Integra-S/Integra-G/Integra-GS FODU (LAN1). The total length of Ethernet cables from CPE to PoE injector (DATA port) and from Integra/Integra-S/Integra-G/Integra-GS to PoE injector (DATA+PWR port) combined should not exceed 100m. It is recommended to use outdoor-rated STP/FTP Ethernet cable Cat5e or better.
INTEGRA/-S/-G/-GS User Manual WEB GUI Universal programmable PoE injector (P/N I0ATPI24/I0ATPI44) The I0ATPI24 and I0ATPI44 injectors are designed to operate with any PoE-capable product with a Fast Ethernet / Gigabit Ethernet interface. Built-in protection conforms to the IEC 61000-4-5 standard.
-19” rack mounting shelf (p/n Mounting I0KTPI11.003) -DIN-rail clip (p/n I0STPI11.01) 2ESDV-02P plug with screw locks included. System requirements To access the Integra/Integra-S/Integra-G/Integra-GS Web GUI you will need a PC with the following Web browser: • Google Chrome; • Mozilla Firefox;...
INTEGRA/-S/-G/-GS User Manual WEB GUI Ethernet management connection configuration Before proceeding with the initial link setup in the Web GUI, you must adjust the IPv4 settings of your LAN adapter to 192.168.205.0 subnet. The IP address should be something other than the default low/high side IP addresses (192.168.205.10/192.168.205.11).
Page 31
INTEGRA/-S/-G/-GS User Manual WEB GUI 5. Select “Remember password” if you want the browser to remember entered login credentials. 6. Press “Log in” button. “Switch to secure connection (HTTPS)” indicates that HTTP protocol is being used. Press on the link and you will be redirected to a secure HTTPS URL.
Main page After login you will be automatically redirected to the Main page of the Web GUI: Web GUI is divided into 5 sections: Top panel Shows information about the Integra/Integra-S/Integra-G/Integra-GS FODU you are connected to including: • Model name •...
Page 33
INTEGRA/-S/-G/-GS User Manual WEB GUI MODIFY / SAVE / LOGOUT Allows modifying parameters in the main window. If none can be modified, the MODIFY button appears inactive. After modification, the SAVE button becomes active and indicates a number of unsaved changes as well as their type (when moving the cursor over the button).
INTEGRA/-S/-G/-GS User Manual WEB GUI Modifying basic system parameters To proceed with the initial configuration, press the MODIFY button and the entry fields will appear for adjustable values: Tx power The available range depends on the radio model and selected modulation. The actual range will be indicated in the brackets.
Page 35
Execute By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied. Rollback triggers when configuration changes applied interrupt management connectivity.
256Kbps and you will see a warning. 2) Radio side – shows the radio side of the local and remote Integra-G. 3) Tx mute – Tx shows if the transmitter is currently muted (“Enabled”) or active (“Disabled”).
Page 37
INTEGRA/-S/-G/-GS User Manual WEB GUI port that you need to use for powering Integra-G, please refer to Powering Integra/Integra-S/Integra-G/Integra-GS FODU and connecting to PC for more information, Error! Reference source not found. LAN2, and LAN3 SFP ports, please refer to SFP ports to see the SFP compatibility.
Over The Air → Radio → Configuration Radio configuration page available menu (Over Air→ Radio→Configuration). Refer to the chapter Radio configuration – extra fields for a description of the extra fields of the 17/24 GHz Integra/Integra-S/Integra-G/Integra-GS FODUs. Status mode Press button. Modify mode SAF Tehnika JSC...
Page 39
INTEGRA/-S/-G/-GS User Manual WEB GUI 1) Tx power – Indicates current Tx (transmit) power value (status mode); allows specifying Tx power value (modify mode). The available range depends on the radio model and selected modulation. The actual range will be indicated in the brackets.
Page 40
Integra-G is shown below. It has a built-in Gigabit Ethernet Network Processor that has three LAN ports: LAN1 - 1Gbps PoE-in port that you need to use for powering Integra-G, please refer to Powering Integra/Integra-S/Integra-G/Integra-GS FODU and connecting to PC for more information, Error! Reference source not found.
Page 41
By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
2+0 aggregation with Integra-S/Integra-GS OMT, a dual-polarized antenna, or a coupler can be used. In the case of 1+1 HSB with Integra-S/Integra-GS, only a coupler can be used (as only a single frequency pair in the same polarization is being utilized).
In the case of ACCP a guard band equal to ¼ BW should be introduced (e.g. 20MHz in the case of 80MHz channels). 5. Configure different IP addresses for all 4 Integra/Integra-S/Integra-G/Integra-GS FODUs. 6. The remote IP address for all units must be entered manually. To do that, remove the selection in the “Auto”...
Page 44
INTEGRA/-S/-G/-GS User Manual WEB GUI Mandatory fiber optic cable between LAN2 (optical) ports on both units. Cable for powering Slave FODU. You can use a 2- wire power cable with DC power adapter (P/N D0ACPW01) or a standard Ethernet cable with the PoE injector.
Page 45
INTEGRA/-S/-G/-GS User Manual WEB GUI Mandatory fiber optic cable between LAN2 (optical) ports on both units. Electrical Ethernet cable (1000Base-T) between PoE injector’s (#1) DATA+PWR port and LAN1 (electrical) port of the Slave FODU. Both data and power are carried, therefore the total length of cables #2 and #6 combined should not exceed 100m.
Page 46
INTEGRA/-S/-G/-GS User Manual WEB GUI Modify mode Slave status after enabling aggregation SAF Tehnika JSC...
Page 47
INTEGRA/-S/-G/-GS User Manual WEB GUI Master status after enabling aggregation Press button. SAF Tehnika JSC...
Page 48
INTEGRA/-S/-G/-GS User Manual WEB GUI Master modify mode after enabling aggregation When all four Integra/Integra-S/Integra-G/Integra-GS FODUs are successfully configured and interconnected, the status of the Master unit should look as shown above. Explanation of status/configuration fields Aggregation configuration 1) Aggregation - Indicates whether aggregation is enabled or disabled.
Page 49
INTEGRA/-S/-G/-GS User Manual WEB GUI 8 states are possible – Master, Slave, Active (transition to Passive, Slave, or Active Try), Passive (transition to Slave), Active Try (1+1 transition to Active Tx), Active Tx (1+1 transmitting), Standby (ready for 1+1 protection), and TpDown (Slave state when Traffic port is down).
Page 50
31) FCS errors on air – Indicates the number of FCS errors received by Slave FODU. Slave path counters By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI 192.168.205.10 192.168.205.20 Configuration for both Master FODUs For 2+0: For 1+1: CLI commands (Chapter 4: COMMAND LINE INTERFACE) aggr status Use to show aggregation status, statistics, and alarms. aggr status clear Use to clear the aggregation statistics.
Page 52
INTEGRA/-S/-G/-GS User Manual WEB GUI connection comprised of multiple hops, these headers are significant, but they can be omitted over a single link. It is beneficial to compress those headers to provide high-capacity packet saving, achieve better bandwidth utilization, and efficiently use expensive resources.
GFP (Generic Framing Procedure) overhead. By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
Page 54
64 hexadecimal characters long. A dialog window will not allow more than 64 characters. By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
Page 55
INTEGRA/-S/-G/-GS User Manual WEB GUI b) Press button. c) Locate *.bin firmware file on your hard disk drive. d) Upload selected *.bin firmware file. e) Select the uploaded *.bin firmware file from the list and press “Upgrade firmware”. The remote side should be upgraded first.
Page 56
INTEGRA/-S/-G/-GS User Manual WEB GUI b) Locate *.lic license file on your hard disk drive. c) Upload selected *.lic license file. d) Select the uploaded *.lic license file from the list and press “Activate”. e) Repeat a)-e) for the local side of the link.
INTEGRA/-S/-G/-GS User Manual WEB GUI b) Press button. c) Enter a 64-symbol key consisting of hexadecimal values (0-9, A-F) or press “Generate random key” button. d) Select and copy the generated key. e) Press “Execute configuration” button. f) Repeat steps a)-e) for the local side of the link using the same copied AES key.
Page 58
INTEGRA/-S/-G/-GS User Manual WEB GUI Status mode Press button. Modify mode 1) VLAN mode – Indicates VLAN operational mode. The default is “Disable” – 802.1Q disabled. Change to “Enable” to enable 802.1Q VLAN support. Change to “QinQ” to enable 802.1ad QinQ VLAN support.
( ) to delete VLAN entry; By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
Page 60
) to delete this entry; 5) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI Networking → Ethernet → Rate limit The rate limit page allows configuring ingress and egress rates on available Ethernet switch ports. In case a license with an Ethernet rate limitation is applied, the Ethernet limitation will be indicated as the egress rate of the WAN port.
(modify mode). The default setting is “2000”. 7) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
Page 63
INTEGRA/-S/-G/-GS User Manual WEB GUI Status mode Press button. SAF Tehnika JSC...
INTEGRA/-S/-G/-GS User Manual WEB GUI Modify mode 1) Use to clear the dynamic MAC address table on a particular port (“Clear”) or all ports simultaneously (“Clear all”). 2) Shows list of MAC address entries (status mode); allows clearing specific MAC address entries (modify mode).
Page 65
MAC address (“Remove”), or deleting permanently entered static MAC address (“Add”). 5) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI Networking → Ethernet → Spanning Tree The Spanning Tree page provides the configuration of Rapid Spanning Tree Protocol (Rapid STP). Status mode Press button. SAF Tehnika JSC...
Page 67
INTEGRA/-S/-G/-GS User Manual WEB GUI Modify mode 1) Bridge ID – Indicates the configured value of Bridge ID (status mode); allows specifying the value of Bridge ID (modify mode). This parameter and MAC address determines whether a given Bridge is Root Bridge. The advantage is given to the combination of Priority and Address, which is numerically smaller.
Page 68
25) Fwd Transitions – Indicates how many times the port has been changed to forward status; 26) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI Networking → Ethernet → Port status and configuration Shows the status of Ethernet switch ports, allows enabling and disabling the ports, Flow control, and modifying link speed/duplex. Status mode Press button. Modify mode 1) Port – Indicates available switch ports.
INTEGRA/-S/-G/-GS User Manual WEB GUI 6) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
Page 71
4) Source port configuration – Allows specifying SyncE source port. 5) Disable/Enable – Allows enabling or disabling SyncE operation. Configuration examples 1) Integra/Integra-S/Integra-G/Integra-GS link with an external clock source 2) Integra/Integra-S/Integra-G/Integra-GS back-to-back interconnection with an external clock source SAF Tehnika JSC...
Page 72
INTEGRA/-S/-G/-GS User Manual WEB GUI 3) Integra/Integra-S/Integra-G/Integra-GS as a master clock source Auto-negotiation will not function properly when the clock source ports on both Integra/Integra-S/Integra-G/Integra-GS FODUs are pointing at each other (e.g. WAN- WAN in a link or LAN-LAN in a back-to-back connection).
INTEGRA/-S/-G/-GS User Manual WEB GUI Polling failed – indicates last data polling failure; Speed Grade – shows Ethernet speed on LAN1 port - 1000BASE-T(1G) or 100BASE-T(100M); Port – current port used as a clock source; State – clock status, "Locked" if SyncE operates normally;...
Page 74
The default setting is the frame-based mode. 6) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI network qos set <port> base Use to enable or disable port-based priorities. state {enable|disable} network qos set <port> base Use to specify the queue of port-based priority. priority <0…7> network qos set sched_mode Use to select the scheduler’s mode – frame (SP/RR/WRR) {frame|byte} or byte (SP/DWRR).
Page 76
(modify mode). 6) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI Networking → QoS → DiffServ mapping The DiffServ mapping page allows customizing the mapping of DSCP priority tags and available QoS queues. Status mode Press button. SAF Tehnika JSC...
DSCP priority values and queues (modify mode). 3) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
Page 79
INTEGRA/-S/-G/-GS User Manual WEB GUI Status mode Press button. Modify mode 1) LAN1/LAN2/LAN3/WAN – Tabs allow selecting a particular port. SAF Tehnika JSC...
Page 80
WAN port. 8) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI scheduler mode {sp|{{rr|wrr}|dwrr}} network qos set <port> cosq Use to assign a weight for a particular queue #. CoSQ scheduler weight <1..255> scheduler should be enabled for that particular port and CoSQ queue <0..7> scheduler mode should be set to WRR or DWRR.
(status mode); allows modifying default mapping of MPLS EXP values and queues (modify mode). 3) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. If „Rollback on” is selected, the configuration will be reverted in case erroneous configuration changes are applied.
INTEGRA/-S/-G/-GS User Manual WEB GUI CLI commands (Chapter 4: COMMAND LINE INTERFACE) log sensor setlist Use to show alarm status. Performance → Alarm → Alarm event log Alarm event log shows 20 alarm entries per page and about 5000 alarm entries in total. The full alarm log can be downloaded by pressing on “Alarm event log file”.
Page 84
INTEGRA/-S/-G/-GS User Manual WEB GUI Modify mode 1) Clear alarm log – deletes all alarm log entries; 2) Toggle period selection – opens/closes period selection controls; 3) Load the latest data – refreshes alarm log and shows last 20 log entries;...
INTEGRA/-S/-G/-GS User Manual WEB GUI <starttime> [<endtime]] log event clear Use to clear alarm log log event configure Use to enable or disable the event log filter. {enable|disable} Use to configure duration in minutes during which filter log event configure dump <1…60>...
Page 86
INTEGRA/-S/-G/-GS User Manual WEB GUI Modify mode 1) Group description (name) – Shows 5 groups of sensors divided by different group data destinations (event; perf; snmp), as well as indicates whether the group is enabled (State); 2) Ungrouped sensor list – Shows the list of sensors not added to any of the existing groups (status mode);...
INTEGRA/-S/-G/-GS User Manual WEB GUI 6) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. CLI commands (Chapter 4: COMMAND LINE INTERFACE) log group info Use to show sensor group configuration. log group create <name>...
Page 88
INTEGRA/-S/-G/-GS User Manual WEB GUI Status mode Press button. SAF Tehnika JSC...
Page 89
2) Set all to default – resets “Low value”, “High value” and “Delta value” for all parameters to factory defaults; 3) Default value – deselect to activate manual threshold modification; 4) By pressing „Execute configuration”, changes made to the corresponding section apply only to the local side Integra/Integra-S/Integra-G/Integra-GS. CLI commands (Chapter 4: COMMAND LINE INTERFACE) log sensor info Use to show the configuration of sensor thresholds.
INTEGRA/-S/-G/-GS User Manual WEB GUI Performance → Monitoring → Performance graph The Performance graph allows visualizing various parameters over a chosen time period as curves. Available parameters will depend on the Sensor Configuration. Any two parameters can be shown at a time. By default Rx level (dBm) and MSE (dB) are selected.
INTEGRA/-S/-G/-GS User Manual WEB GUI 1) Left axis sensor – Allows choosing a sensor parameter colored in red and displayed on the left axis. 2) Right axis sensor – Allows choosing a sensor parameter colored in blue and displayed on the right axis.
Page 92
INTEGRA/-S/-G/-GS User Manual WEB GUI 1) Select sensors – Allows choosing the sensor parameters to be displayed in the performance log. 2) Select fields – Allows choosing the parameter fields to be displayed in the performance log. “Minimum” and “Maximum” represent the minimum and maximum values in the specified sensor log step, while “Average”...
INTEGRA/-S/-G/-GS User Manual WEB GUI log perf clear Use to clear performance log. Performance → Ethernet → Ethernet switch statistics SAF Tehnika JSC...
Page 94
INTEGRA/-S/-G/-GS User Manual WEB GUI Status mode SAF Tehnika JSC...
Need help?
Do you have a question about the Integra and is the answer not in the manual?
Questions and answers