Download Print this page

SAF Integra User Manual page 84

Advertisement

INTEGRA/-S/-G/-GS User Manual
Modify mode
1) Clear alarm log – deletes all alarm log entries;
2) Toggle period selection – opens/closes period selection controls;
3) Load the latest data – refreshes alarm log and shows last 20 log entries;
4) List of alarm log entries – entry number, date and time, source node, status, and
event name;
5) Navigation controls. "<<" navigates to the start of the alarm log, while ">>" – to the
end; "Previous 20" navigates to the previous alarm log page showing 20 previous
alarm log entries (if available), while "Next 20" – to next alarm log page showing 20
next alarm log entries (if available).
6) Shows the number of the currently viewed alarm log page. You can enter the specific
page number to navigate to the required page;
7) Filter – press to filter alarms from a certain source node (e.g. Radio);
8) Alarm event log file – press the link to download the full alarm log text file.
CLI commands
(Chapter 4: COMMAND LINE
log event show last <#_of_entries>
log event show time <starttime>
[<endtime>]
log event show sensor <sensor>
[last <#_of_entries>] [time
<starttime> [<endtime>]]
log event show module {modem|
psu | radio | system | alarm_only |
iman} [last <#_of_entries>] [time
SAF Tehnika JSC
INTERFACE)
Use to show a certain number of last alarm log entries.
Use to show entries from a certain time point. The
following formats are supported:
YYYY-MM-DD/hh:mm:ss; MM-DD/hh:mm:ss;
MM-DD/hh:mm; hh:mm:ss; hh:mm
Use to show entries for a specific sensor. Regarding
subcommands "last" and "time" refer to the commands
above.
Use to show entries for a specific module. Regarding
subcommands "last" and "time" refer to the commands
above.
WEB GUI