Page 3 of 6
2
Recommended
3
1. Pull caps out
at two sides.
4
Lum or control box flying cable(1.5m)
5
Not recommended
Adjusting angle of luminaire
Mounting surface is perpendicular
to luminous surface when triangle
mark pointing at 0°
2
3X1.0mm
Power cable connection
80 mm
Blue : N
Brown: L
50 mm
8 mm
M3
External cable connection
3. Fasten the bolts
after adjustment.
M10 (2x) 50N.m
2. Unlock bolts
at two sides for
adjusting angle.
60245IEC57
3 pole 1mm2 Multi-core with rubber insulated layer
Warning: Water proof is needed for cable
!
connection, if without proper water proof,
the water ingression will cause luminaire
short circuit or other failures. Water proof
connection box is recommend, which is
not lower than IP66.
Recommend: Above IP66 Connection box
Notice: Connection box is not provided by Signify.
Notice: Correct connection for polarities
4. Put two caps back
on the bolts.
15-12-2021
30-08-2021
Approved
Approved