2
Recommended
3
1. Pull caps out
at two sides.
4
Recommend: Above IP66 Connection box
Notice: Connection box is not provided by Signify.
!
Notice: Correct connection for polarities
5
1. Press the cover
Not recommended
Adjusting angle of luminaire
Mounting surface is perpendicular
to luminous surface when triangle
mark pointing at 0°
2
3X1.0mm
Power cable connection
80 mm
Blue : N
Brown: L
50 mm
8 mm
M3
Open Gear cover
2. unlock the knob
3. Fasten the bolts
after adjustment.
M10 (2x) 50N.m
2. Unlock bolts
at two sides for
adjusting angle.
60245IEC57
3 pole 1mm2 Multi-core with rubber insulated layer
Warning: Water proof is needed for cable 
!
connection, if without proper water proof, 
the water ingression will cause luminaire 
short circuit or other failures. Water proof 
connection box is recommend, which is 
not lower than IP66.
2
2X1.0mm
* (ETO)
50 mm
60245IEC57
2 pole 1 mm2 Multi-core with rubber insulated layer
4. Put two caps back
on the bolts.
Blue
(1-10V+ or DA)
Brown (1-10V- or DA)
8 mm
3. Open the cover
23-07-2021