The additional fan is switched on by the dryer (via Connector Box) in parallel with the in-
ternal fan.
- Off
- On

Pressure sensor

External hardware is connected via the Miele Connector Box.
When using a shared exhaust air duct, one tumble dryer may have to be switched off or
suppressed from the outset if certain pressure levels have built up in the ducting. The ex-
ternal pressure sensor is only checked if the external exhaust air flap and/or the external
additional fan is set to "on".
A message appears in the display while the exhaust air flap is open.
- Off = Not active
-
= Active
NO contact
Responds to high potential
-
NC contact
= Active
Responds to low potential

Peak load signal

External hardware is connected via the Miele Connector Box.
The peak-load negotiation function enables the tumble dryer to be connected to an energy
management system. When a signal is registered, the tumble dryer's heater is switched off
for a short period or the machine is prevented from being switched on.
A peak-load signal can be issued via the Connector Box or via the COM module.
- Factory default:
No function
-
Peak load with 230 V
-
Peak load with 0 V
-
COM module

Peak load prevention

- Factory default:
Off
-
On

COM module selection

This tumble dryer is equipped with an integrated WiFi module. However, the dryer can also
be equipped with an external module.
- Factory default:
Off
-
Internal mod. Domestic
The internal WiFi module is used.
-
External mod. Professional
An XKM module is inserted into the module slot.
en - Supervisor level