Connecting the refrigerator

7 Connecting the refrigerator
A
NOTICE! Damage hazard
Lay the connection cables so that they do not come into contact with hot parts of the
device or with sharp edges.
7.1 Connecting to the gas supply
The assembly and installation of the gas connection must be performed by a qual-
ified person who has demonstrated skill and knowledge related to the construc-
tion, installation and operation of gas appliances and has received safety training
to identify and avoid the hazards involved.
!
WARNING! Fire hazard
After installation, it must still be possible to shut off the refrigerator from the supply
mains separately from the gas line.
A
NOTICE! Damage hazard
• Only use universal LPG gas cylinders equipped with an approved gas pressure reg-
ulator. Compare the pressure specifications on the data plate with the pressure
specifications on the pressure regulator of the gas cylinder.
• Only operate the refrigerator at the pressure specified on the data plate.
• Only operate the refrigerator with the type of gas specified on the data plate.
• Only use pressure controllers with a fixed setting which comply with the national
regulations.
• The pressure of the gas supply must be 2.75 kPa. Check the pressure at the test
point before using the refrigerator (fig. k 1).
k
22
RUA 5308X, RUA 6508X, RUA 8508X
1
EN

Advertisement

loading

This manual is also suitable for:

Rua6508xRua8508x