Connecting the refrigerator
Connection variant D (fig. q)
q
Vehicle Anderson plug must
be controlled by ignition relay.
• Anderson plug controlled from the house battery.
• D+ is switched on and off via a fridge motion switch (not included), depending on whether the vehicle is in
motion or not.
• House battery is charged by the vehicle.
Connection variant E (fig. r)
r
Vehicle Anderson plug must
be controlled by ignition relay.
• Anderson plug recharging the house battery via a power diode (not included in the scope of delivery). The D+
wire can only receive a 12 V signal when the battery is being charged.
• D+ is switched on and off by the vehicle starting and stopping.
• House battery is charged by the vehicle.
28
RUA 5308X, RUA 6508X, RUA 8508X
Refrigerator DC connections
D+
Power Module
25
House Battery
Anderson Plug
Anderson cables must be the
recommended size.
Refrigerator DC connections
D+
House Battery
Anderson Plug
Anderson cables must be the
recommended size.
Heater
+
-
+
-
26
Power Module
Heater
+
-
+
25
26
23
Fridge
Switch
-
23