6.3 Making air inlet and outlet vents
I
NOTE
Observe the required dimensions specified in the installation manual for the LS ventila-
tion grille and the roof vent kit.
➤ Make cut outs in the wall for the air inlet and outlet vents.
Position of the air inlet vent
• It must be possible to install the ventilation grille so that the lowest opening of the ventilation grille is flush with
the bottom of the refrigerator.
• If the air inlet vent cannot be aligned so that the lowest opening of the ventilation grille will be flush with the bot-
tom of the refrigerator, make an additional gas outlet opening in the floor to ensure all unburned gas will escape
(see chapter "Making a gas outlet opening" on page 14).
Position of the air outlet vent
• Side venting (fig. 4, page 11):
– It must be possible to install the ventilation grille so that the bottom of the ventilation grille will be below the
top of the refrigerator.
– The top of the ventilation grille may be above the top of the refrigerator.
– RUA 5308X only: The ventilation grille must be able to be installed so that the lowest opening of the ven-
tilation grille is >935 mm from the bottom of the refrigerator.
– Ensure that the bottom of the condenser fins are no more than 0.5 m above the air outlet vent.
• Roof venting (fig. 5, page 12):
– The air outlet vent must be located directly above the cooling unit at the rear of the refrigerator.
– If the air outlet vent cannot be installed directly, but only offset above the back of the refrigerator:
Install an air duct to prevent the heat from accumulating.