Internal supply:
Do not seal the marked hole with the black
turnable gasket (Fig. 5-5, left).
External supply:
Seal the marked hole with the black turnable
gasket (Fig. 5-5, right).
Fig. 5-5: CNOMO interface: location of the
turnable gasket for internal supply (left)
and for external supply (right)
Î Carefully place the CNOMO interface
onto the booster valve. Make sure that all
gaskets are seated properly on the boost-
er valve.
Observe direction on installation:
The port 9 (external pilot supply) of the
CNOMO interface must be located on the
same side as port 1 (supply) or port 3 (ex-
haust) of the booster valve.
Î Use the two hexagonal socket head
screws to fasten the CNOMO interface
(Fig. 5-3).
EB 3756 EN
5.5 Connecting the electrical
power supply
The device does not have any electrical con-
nection. To use the booster valves with a pilot
valve, the specifications written in the mount-
ing and operating instructions of the pilot
valve apply for the electrical connection.
Installation