Heat Rejection - Follett Champion 7 Installation Manual

Ice and water dispenser with chewblet ice machine
Table of Contents

Advertisement

Water
WARNING!
Connect to potable water supply only.
§ Maximum total dissolved solids (TDS) 400 ppm. Ion exchange filtration or RO can reduce hardness.
§ Minimum TDS 10 ppm.
§ Maximum silica 20 mg/L. Reverse osmosis (RO) must be used to remove silica.
§ Maximum water hardness 100 ppm as CaCO3 (6 grains per gallon). Ion exchange filtration or RO can reduce
hardness.
§ Not recommended for use with sodium softened water
§ Ingress Protection (IP) rating: IPX0 (no protection)
§ Use provided water hardness test strips to verify incoming water hardness and adjust bypass setting on Claris
filter head (preinstalled behind front cover on most models). Refer to the below table for appropriate settings.
Adjust the bypass setting after completing the Internal Claris Filter Flushing Sequence section.
Hardness (ppm)
50
120
250
425
Note: Claris filter manifold is factory set at 3 prior to shipment.
Clearances
§
CI Models:
§
UD/UC Models: 2" (5.08 cm) behind dispenser for electrical and optional drain connection. 6" (15.3 cm) in
Electrical
230 V
§ 230 V, 50 Hz, 1 phase, 2A, maximum fuse or breaker 10A.
§ Connect to dedicated 10A circuit, fuse or breaker.
§ Equipment ground required.
§ 8' (2.4 m) cord supplied with machine.
§ Replacement cord instructions, type IEC 60320-C13 attachment. If the supply cord is damaged, it must be
replaced by a special cord or assembly available from the manufacturer or its service agent.
Refrigeration
Caution!
Risk of fire. All service on refrigeration system must be performed in accordance with all federal, state and
local laws that pertain to the use of refrigerants. It is the responsibility of the technician to ensure that these
requirements are met.
§ Refrigerant
– 230 V: R290 - 3.3 ounces (93 grams)

Heat Rejection

§ 1700 BTU/hr (498 W)
Setting
0
3" (7.62 cm) on each side of dispenser, 2" (5.08 cm) behind for electrical/water connection/
ventilation
front of dispenser for ventilation.
Interval (month)
6
5
3
2
0
Champion Dispenser and Ice Machine - 230 V
12
9
6
4
2
Gallons
1000
800
500
200
100
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Champion 15Ci114aUc114aUd114a

Table of Contents