Warning Type:
The warning type is field selectable either TONE or VOICE. In secure status, the LED Bar displays a 15 segment or 30 segment LED light. Each
segment represents. Upon activation of the irreversible Release Time cycle, the LED Bar segment display begins to turn off one by one. In
VOICE mode, the countdown will be counted along with verbal exit guidance. When the LED bar display reaches zero, the lock will release.
The verbal voice guidance changes to a continuous verbal instruction announcing, "Door Unlocked". In TONE ONLY mode, the countdown
will be accompanied with a beeping tone only, and a continuous tone is heard once the Release time cycle ends.
Languages:
The voice message can be in 3 languages which are field selectable. The languages are English (Default), French and Spanish.
Voice Type:
For English only, the voice type is field selectable for either a male or female voice.
Examples:
- 15 seconds Mode: "Door will unlock in 15 seconds; Door will unlock in 5 seconds; Door unlocked..."
(Both messages repeat "Door unlocked" until the lock is reset).
- 30 seconds Mode: "Door will unlock in 30 seconds; Door will unlock in 20 seconds; Door will unlock in 10 seconds;
Door will unlock in 5 seconds; Door unlocked..."
Door POS Alarm (DPA):
- DPA Active: The lock will enter alarm mode when the door is held open past the R-Exit time period triggering a buzzing tone or
alarm voice and the DPA can be Reset by the built-in key switch or remote reset.
- DPA Inactive: The lock will enter stand-by mode which will remain unlocked if the door is held open past the R-Exit time set.
No warning sound is emitted. The Lock can re-lock upon closure of the door.
Anti-Pass Back
If door doesn't open after the count down, the door will re-lock after a set time frame: 1 or 5 seconds.
Dip Switch Position
Release Time
ON : 30 seconds
OFF : 15 seconds
Nuisance Time
ON : 2 seconds
OFF : 1 second
R-Exit Time
ON - ON
: 1s
ON - OFF : 20s
OFF - OFF : 15s
OFF - ON : 30s
7. CONFIGURATION
Delay
Configuration
Release
Options
Switch 1
N1
15
OFF
30
ON
All options selectable
N2
15
Not
Used
15
NFPA Compliant
N3
30
Not
Used
30
NFPA Compliant
(Both messages repeat "Door unlocked" until the lock is reset).
ON
ON
DIP
1 2 3 4 5 6 7 8
OFF
Nuisance
Request to Exit Period
Delay
Switch 2
Switch
3
1
OFF
1 Sec
ON
ON
2
ON
15 Sec
OFF
OFF
20 Sec
ON
OFF
30 Sec
OFF
ON
0
OFF
1 Sec
ON
ON
1
ON
15 Sec
OFF
OFF
20 Sec
ON
OFF
30 Sec
OFF
ON
0
OFF
1 Sec
ON
ON
1
ON
15 Sec
OFF
OFF
20 Sec
ON
OFF
30 Sec
OFF
ON
Anti Pass Back
Warning Type
ON : 1s
OFF : 5s
ON : Voice
OFF : Tone
Door POS Alarm (DPA)
ON : Alarm Mode
Languages
OFF : Standby Mode
ON - ON : French
OFF - OFF : English
Start-up State
OFF - ON : Spanish
ON : Locked
OFF : Unlocked
ON - OFF : French (Standby)
Trigger Type
ON : External
OFF : Internal
Trigger
Power-Up
Type
State
4
Switch 5
Switch 6
Internal
OFF
Unlocked
External
ON
Locked
Internal
OFF
Unlocked
External
ON
Locked
Internal
OFF
Unlocked
External
ON
Locked
CX-DE1220 Double Door (Main and Tandem Lock)
I N S TA L L AT I O N I N S T R U C T I O N S
ON
DIP
1 2 3 4
Door Prop
Anti-Pass
Open
Switch 7
Switch 8
Stand-
OFF
OFF
5
by
ON
Alarm
ON
1
Stand-
OFF
OFF
5
by
ON
Alarm
ON
1
Stand-
OFF
OFF
5
by
ON
Alarm
ON
1
ON
OFF
Voice Type
ON : Male
OFF : Female
Note:
Only English version
has a Female Voice.
Reset After
Back
ALARM
OFF
Fixed Manual
ON
OFF
Fixed Manual
ON
OFF
Fixed Manual
ON
Page 9 of 10