MODULE SPECIFIC SYNTAX

The Module Specific Syntax for the 1260-64 is required for use in
the OPEN and CLOSE commands. It will also appear in data
output by the 1260 Series Master in response to the PDATAOUT
command.
The Module Specific Syntax for the 1260-64 module is as
follows:
<mod addr>.<bank no><relay no>
where <mod addr> is the address of the 1260-64.
The <mod addr> used here is NOT the VXIbus
defined logical address of the 1260 Series Master. It
is peculiar to the 1260 Series and describes the
switching module in relation to the 1260 Master. This
address corresponds to the binary value of the
switch setting of SW1 on the switching module PCB.
<bank no> is a reference to the bank of the relay to be switched.
It is a single digit number. The range for a valid <bank no>
depends on the particular 1260-64 model used:
0 ≤ <bank no> ≤ 5
1260-64A:
0 ≤ <bank no> ≤ 3
1260-64B:
0 ≤ <bank no> ≤ 2
1260-64C:
The <bank no> refers to the following relay banks:
0
1x16 Bank A
1
1x16 Bank B
2
1x6 Relay S1
3
1x6 Relay S2 (A and B models only)
4
1x6 Relay S3 (A model only)
5
1x6 Relay S4 (A model only)
<relay no> refers to the relay to be operated. This is a two-digit
Chapter 3
NOTE
Module Specific Syntax 3-1