MODULE SPECIFIC SYNTAX

The Module Specific Syntax for the 1260-36 is required in the use
of the OPEN and CLOSE commands. It also appears in data
output by the Master in response
commands.
The Module Specific Syntax for the 1260-36 F.E.T.
Multiplexer/Scanner module is as follows:
<module address>.<group> <channel number>
where <module address> is the address.
<group> is the reference number of the mux on which a
channel is to be closed; value 0 to 11
<channel number> is the reference number of the
hannel to be closed; value 0 to 7
The <module address> used here is not the VXIbus
defined logical address of the 1260 Series Master. It
is unique to the 1260 Series and describes the
switching module in relation to the Master. This
address corresponds to the binary value of the switch
setting of SW1 on the switching module PCB.
The actual mapping of number to connector pins is given in Table
3-1. Figure 3-2 shows the physical location of the various
connector pins.

Table 3-1, 1260-36 Channel Closure

Chapter 3
the PDATAOUT and PSETUP
to
NOTE
Module Specific Syntax 3-1