Eizo RadiForce LX600W Instructions For Use Manual
Eizo RadiForce LX600W Instructions For Use Manual

Eizo RadiForce LX600W Instructions For Use Manual

8mp 60.1" lcd monitor

Advertisement

Quick Links

Instruction for Use
8MP 60.1" LCD Monitor
Important
Please read the Safety Information and the information
delivered with the product carefully to familiarize yourself with
safe and effective usage.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RadiForce LX600W and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eizo RadiForce LX600W

  • Page 1 Instruction for Use 8MP 60.1" LCD Monitor Important Please read the Safety Information and the information delivered with the product carefully to familiarize yourself with safe and effective usage.
  • Page 2: Legal Information

    Note the following: WARNING EIZO products may only be used for the applications described in the catalog and in the relevant tech‐ nical documentation. If products and components from other manufacturers are used, these must be recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Graphics controller settings..................27 Check for pixel defects.................... 28 7 Operation......................... 29 8 Cleaning and maintenance..................... 30 Cleaning........................30 Maintenance......................31 9 Troubleshooting......................33 10 Technical specifications....................34 10.1 Monitor characteristics.................... 34 10.2 Power supply......................34 RadiForce LX600W Instruction for Use, 11/2013...
  • Page 4 12.2 Markings and symbols.................... 42 12.3 Warranty........................43 12.4 Repairs........................43 12.5 Environmental protection..................43 12.6 Accessory devices....................44 12.7 Contact........................44 12.8 Trademarks......................44 12.9 China RoHS (Restriction of Hazardous Substances)..........45 Index..........................47 RadiForce LX600W Instruction for Use, 11/2013...
  • Page 5: Introduction

    In the following, health personnel such as radiologists or MTAs are referred to as the "user". Service/service personnel The terms "service" or "service personnel" denote specially trained and authorized person‐ nel, e.g. hospital technicians, medical device manufacturers. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 6: Safety Instructions

    General safety notes Correct transport, professional storage, installation and connection, as well as careful opera‐ tion and maintenance, are required to ensure that the EIZO devices operate safely and cor‐ rectly. The devices may only be used for applications for which they are commonly used.
  • Page 7 Touching the components may be fatal. No contact between device and patients The device is not suitable for direct contact with patients. Device and patient must never be touched simultaneously. Otherwise there is a danger to life and limb. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 8 Only use power cables approved for China. These power cables are identified by the labels "CCC" or "CQC". Observe the country-specific regulations Observe all regulations of the country in which the device is used. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 9 If the device is brought into a room with a higher or rising temperature, condensed water will form in and on the device. Do not switch on the device until the condensed water has evaporated. Otherwise the device could be damaged. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 10 Note that monitors can fail as a result of aging, and that image properties such as brightness, con‐ trast, and color value can change. Do not touch the monitor screen Due to mechanical pressure or electrostatic discharging, touching the screen can result in brief dis‐ turbances to the image. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 11: Product-Specific Safety Instructions

    This is a class A device. The device may cause radio interference or interfere with the operation of other devices in close proximity. In this case the user is encouraged to perform appropriate measures to correct the interference. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 12: Description

    Particularly when used together with the LMM56800 Large Monitor Manager or LMM0802, the versatile monitor can be used for various applications, e.g. angiography, EP, or cardiolo‐ gy. It can replace up to eight 1MP monitors. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 13 (IP65 degree of protection). The space between the protec‐ tive pane and the panel is sealed to prevent dust from entering, thus helping ensure the in‐ ternal surfaces remain clean. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 14: Medical Subsystem

    3.3 Medical subsystem Medical subsystem NOTICE Only trained and qualified personnel The device may only be used by trained and qualified personnel. The RadiForce LX600W can be part of a medical subsystem comprising the following com‐ ponents. Mandatory Devices • RadiForce LX600W •...
  • Page 15: Setup And Installation

    CAUTION Changes to device Do not make any mechanical or electric changes to the device. EIZO GmbH will not be held liable if changes are made to the device. Installation site Note the following conditions at the installation location. NOTICE The power switch and connections must be accessible at all times When installing and connecting the monitor, ensure that the power switch and the connec‐...
  • Page 16: Unpacking The Monitor

    • Make sure the monitor cannot tip over. • The monitor must be removed from the packaging and carried by at least two persons. • Wear appropriate protection to prevent injuries should the monitor fall. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 17 1. Carefully open the packaging and remove the upper section of the carton as well as all accessible packing parts. 2. Lift the monitor from the base of the packing carton. Hold it on the side and underside. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 18: Mounting The Monitor

    An installed stand must be sufficiently stable such that tilting up to 10° does not result in the monitor toppling. Note Wall mount EIZO recommends the FWM6300wall mount, because it has been tested with the monitor and meets all necessary conditions. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 19: Connecting

    CAUTION Changes to device Do not make any mechanical or electric changes to the device. EIZO GmbH will not be held liable if changes are made to the device. CAUTION Shielding measures Follow all shielding measures according to the country-specific EMC Directive. If these guidelines are not observed, device malfunction may result.
  • Page 20 • Externally connected cables can represent a trip hazard. Make sure that all incoming cables are safely routed. • If the device includes cable grips, please use them to prevent unintended loosening of connected cables. See also Safety instructions Electromagnetic compatibility RadiForce LX600W Instruction for Use, 11/2013...
  • Page 21: Device Connectors

    5 V supply for external devices ⑥ 5 V supply for external devices ⑦ DVI B (front view: left half) ⑧ USB (upstream) ⑨ Additional grounding screw Power connector The device's power supply is connected using an appliance plug. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 22 • Only photometers tested for calibrating the monitor may be connected to the serial in‐ terface. • A photometer must not be connected in the presence of the patient. See also Power connector DVI connector RadiForce LX600W Instruction for Use, 11/2013...
  • Page 23: Power Connector

    Power cables, power supply plugs and appliance plugs must be CCC-certified. NOTICE Line voltage and frequency Before connecting the device, make sure the line voltage and frequency correspond to the specifications on the name plate. See also Device connectors RadiForce LX600W Instruction for Use, 11/2013...
  • Page 24: Dvi Connector

    The monitor can process digital DVI input signals. There are two dual-link DVI connectors (A and B) for this purpose. • Only use the Dual Link DVI cables specified by EIZO or the transmission links available from EIZO. The picture quality, noise immunity, and radiated interference of the entire system de‐...
  • Page 25 5. Connect DVI cables directly to the DVI sockets. Only Dual Link DVI cables with a corre‐ spondingly high quality may be used. 6. If TDL3600-QL modules from EIZO are used: Connect CAT cables to the connections of the DVI receiver modules, and tighten the clamps.
  • Page 26: Commissioning

    Image sticking may occur with LCD monitors. Image sticking is an effect whereby a faint im‐ age of the previous screen contents can be seen after the display contents have changed. The following measures can reduce or prevent image sticking: RadiForce LX600W Instruction for Use, 11/2013...
  • Page 27: Graphics Controller Settings

    Note Installation and parameterization of the graphics card Please refer to the graphics controller manufacturer’s manual for detailed information about installation and configuration of the graphics controller. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 28: Check For Pixel Defects

    Check for pixel defects Pixel defects (small bright or dark dots) can occur in LCD monitors. During the manufactur‐ ing process, all monitors are checked for the permitted number of defective pixels. Defective pixels cannot be corrected. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 29: Operation

    Measures in the event of a failure Note Device malfunction in operation If the device is not working properly, check the system for incorrect connection or opera‐ tion before contacting Service. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 30: Cleaning And Maintenance

    Cidex, undiluted Kohsolin Gigasept FF Chlorine derivatives Terrain 0.5% by vol. Quartamon Med Disinfecting agents Perform 3% by weight Morning Mist (1:64) Terralin Protect 2% by vol. Mikrozid Sensitive Liquid, undi‐ luted Microbac Tissues RadiForce LX600W Instruction for Use, 11/2013...
  • Page 31: Maintenance

    Correct the settings if necessary. Carrying out quality tests All quality tests can be performed using the EIZO RadiCS program. Checking, changing, and calibrating settings You can check and change the monitor settings and calibrate them if necessary using a photometer and suitable software.
  • Page 32 SMPTE pattern: The gray levels must be displayed correctly and visibly at both 5% and 95%. • VeriLum pattern: The visible display of small squares in all gray scale levels confirms the correct calibration. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 33: Troubleshooting

    Lamp warm-up period: Inform servicing department Setting is active, and the warm-up pe‐ riod has expired without the monitor having reached the stabilized lumi‐ nance level. Internal error Inform servicing department RadiForce LX600W Instruction for Use, 11/2013...
  • Page 34: Technical Specifications

    Energy saving mode < 41 W 10.3 Inputs/outputs DVI input Dual link DVI-I socket (analog pins are not used) - 3840 x 2160 (QFHD) at 60 Hz Service and communication over DDC of DVI socket B RadiForce LX600W Instruction for Use, 11/2013...
  • Page 35: Controls And Connectors

    IP20 according to EN 60529 IP20: Front sealed in accordance with IP65 Connector panel On rear panel, under cover Weight • RadiForce LX600W 52 kg +/- 3 kg • RadiForce LX600WP 62 kg +/- 3 kg Dimensions (W x H x D) in mm •...
  • Page 36: Mechanical Requirements

    CAN/CSA - C 22.2 No. 601.1-M90 • CAN/CSA - C 22.2 No.60601-1-08 • GB4943.1 (non-tropical, altitude < 2000 m) Protection class Protection class I Degree of protection IP20 Conformity CE according to MDD 93/42/EEC (Class I) RadiForce LX600W Instruction for Use, 11/2013...
  • Page 37: Electromagnetic Compatibility

    EN 61000-4-11 Line reaction to harmonics EN 61000-3-2:2006 + A1:2009 + A2:2009 GB17625.1 Line reaction to voltage fluctuations EN 61000-3-3 Limits of radio disturbance characteristics GB9254 See also Guidance and manufacturer's declaration – electromagnetic emissions RadiForce LX600W Instruction for Use, 11/2013...
  • Page 38: Dimensional Drawings

    Dimensional drawings 11.1 Dimensions of RadiForce® LX600W Dimensional drawings All dimensions in mm 11.1 Dimensions of RadiForce® LX600W Front view 1390 1335 RadiForce LX600W Instruction for Use, 11/2013...
  • Page 39 Dimensional drawings 11.1 Dimensions of RadiForce® LX600W View from above, right and rear - with cover 1390 1285 1151 RadiForce LX600W Instruction for Use, 11/2013...
  • Page 40: Dimensions Of Radiforce® Lx600Wp

    Dimensional drawings 11.2 Dimensions of RadiForce® LX600WP 11.2 Dimensions of RadiForce® LX600WP Front view 1390 1335 RadiForce LX600W Instruction for Use, 11/2013...
  • Page 41 Dimensional drawings 11.2 Dimensions of RadiForce® LX600WP View from above, right and rear - with cover 1390 1285 1151 RadiForce LX600W Instruction for Use, 11/2013...
  • Page 42: Appendix

    Appendix 12.1 Guidance and manufacturer's declaration – electromagnetic emissions The RadiForce LX600W monitor is intended for use in the environment specified below. The user of the monitor should ensure that it is used in such an environment. Interference emission Compliance Electromagnetic environment –...
  • Page 43: Warranty

    12.4 Repairs Please contact the sales partner from whom you purchased the product. 12.5 Environmental protection Please observe all local requirements and laws pertaining to the disposal of devices. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 44: Accessory Devices

    12.8 Trademarks EIZO Logo is a registered trademark of EIZO Corporation in Japan and other countries. EIZO is a registered trademark of EIZO Corporation in Japan and other countries. RadiForce is a registered trademark of EIZO Corporation in Japan and other countries.
  • Page 45: China Rohs (Restriction Of Hazardous Substances)

    EFUP shall be done in accordance with the Product Maintenance Procedures. This product must not be disposed of as unsorted municipal waste, and must be collect‐ ed separately and handled properly after decommissioning. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 46 Applications of hazardous substances in this medical device are required to achieve its intended clinical uses, and/or to provide better protection to human beings and/or to environment, due to lack of reasonably (economically or technically) available substitutes. 产品中有毒有害物质或元素的名称及含量 Table of hazardous substances’ name and con‐ centration. RadiForce LX600W Instruction for Use, 11/2013...
  • Page 47: Index

    Failure safety Fully Automated Stability TDL module General safety notes USB connections Graphics card User Grounding measures Grounding screw Ventilation Integrated stability system Wall mount Warranty Large Monitor Manager Luminance distribution Zero error rate Maintenance RadiForce LX600W Instruction for Use, 11/2013...
  • Page 48 Siemensallee 84 76187 Karlsruhe Germany Instruction for Use, 11/2013 RadiForce LX600W 1031442-003 Copyright © 2013 EIZO GmbH. All rights reserved.