Page 1
Instructions for Use CuratOR LX3240-MR 8 MP 32" LCD Monitor Important Please read the safety information and all information delivered with the product carefully to familiarize yourself with safe and effective usage.
Use of EIZO products WARNING EIZO products may only be used for the applications described in the catalog and in the relevant tech- nical documentation. If products and components from other manufacturers are used, these must be recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
1.2 Intended use Intended purpose The CuratOR LX3240-MR is intended for the display of still images and moving images from various commercially available devices commonly used in a medical environment, in partic- ular radiology. The monitor is optimized for the reproduction of grayscale X-ray images. The monitor is not suitable for mammography.
2 Safety information 2.1 General safety instructions Correct and safe operation of EIZO devices assume professional transport, storage, installa- tion, and connection, as well as careful operation and service. The devices may only be used for applications for which they are intended.
Page 8
Only use power cables approved for China. These power cables are identified by the labels "CCC" or "CQC". Observe the country-specific regulations Observe all regulations of the country in which the device is used. CuratOR LX3240-MR Instructions for Use, 06/2022...
Page 9
If the device is brought into a room with a higher or rising temperature, condensed water will form in and on the device. Do not switch on the device until the condensed water has evaporated. Other- wise, the device could be damaged. CuratOR LX3240-MR Instructions for Use, 06/2022...
Page 10
Note that monitors can fail as a result of aging, and that image properties such as brightness, con- trast,and color value can change. Do not touch the monitor screen Due to mechanical pressure or electrostatic discharges, touching the screen can result in brief distur- bances to the image. CuratOR LX3240-MR Instructions for Use, 06/2022...
2.2.1 MRI Safety CuratOR LX3240-MR MRI Safety Information The monitor CuratOR LX3240-MR may be safely used in the MR environment under the following conditions. Failure to follow these conditions may result in injury. Name/Identification of medical device...
2.2.2 MRI Safety PSU CuratOR LX3240-MR MRI Safety Information The power supply unit PSU CuratOR LX3240-MR may be safely used in the MR environment under the following conditions. Failure to follow these conditions may result in injury. Name/Identification of medical device...
Note Keep the packaging material for subsequent transport of the device. Device The 8MP 32" LCD Monitor is a CuratOR LX3240-MR. The monitor can be installed on a ceil- ing suspension, wall mount, or mobile medical system. Product Order number...
Page 14
The LX3240-MR is a conditionally MR safe medical device. It was only tested for MR com- patibility against a 1,5 T scanner, with a magnetic field of up to 100 mT for the monitor and up to 3 mT for the external power supply unit PSU CuratOR LX3240-MR . Communication interface As communication interface the DisplayPort or USB connection is available.
In the worst case, deposits are possible which become evident as dark spots in a white picture and result in deterioration of the luminance. • Protect the monitor from dust, for example through appropriate construction measures at the installation site. CuratOR LX3240-MR Instructions for Use, 06/2022...
Page 16
If the monitor is installed such that it can move, make sure that persons or objects in the facility are not endangered by the monitor's range of movement. Note During transport, use the original packaging or service packaging. CuratOR LX3240-MR Instructions for Use, 06/2022...
The maximum torque for attaching to the holder is 3 Nm. • The screws used for attaching to the holder must meet the following requirements: Thread Strength 8.8 in accordance with ISO 898-1 Insertion depth 5 mm ~ 10 mm CuratOR LX3240-MR Instructions for Use, 06/2022...
Device settings may only be adjusted by service personnel. NOTICE Disconnecting from line power Always set the power switch to "Off" before disconnecting the device from power. Other- wise the device could be destroyed. CuratOR LX3240-MR Instructions for Use, 06/2022...
The power switch is not covered and is freely accessible. NOTICE Isolating the device from mains supply Means of isolating the device from mains supply is by disconnecting the AC power line. • Make sure that the AC power line is easily accessible. CuratOR LX3240-MR Instructions for Use, 06/2022...
Page 20
Connecting 5.2 Device connectors Cover Control panel Power switch Screws attaching the cover Kensington lock Fig.: Rear view with cover Attachments for Connection panel Grounding screw cable ties Fig.: Rear view without cover CuratOR LX3240-MR Instructions for Use, 06/2022...
The monitor has two DisplayPort and two DVI connectors (HDMI connectors) for processing digital input signals. The DP1 connector is a DP1.2 input for processing signals with a maximum resolution of 3840 x 2160 (UHD). The other inputs upscale FHD signals to UHD. CuratOR LX3240-MR Instructions for Use, 06/2022...
). The cable must comply with the safety regulations of the respective country. CAUTION Connection in the USA and Canada Molded power plugs must comply with the requirements for "hospital grade attachments" CSA Std. C22.2 No. 21 and UL 498. CuratOR LX3240-MR Instructions for Use, 06/2022...
Note Attachments for cable ties Use the attachments on the back of the device to secure cables or modules to the device with a cable tie, for example. CuratOR LX3240-MR Instructions for Use, 06/2022...
Page 24
3. If external devices need to be supplied with 5 V voltage and up to 1 A, connect them to the "5V/1A" outputs using suitable cables. 4. Connect the (24 V DC) external power supply unit to the line power. ð The monitor can now be switched on. CuratOR LX3240-MR Instructions for Use, 06/2022...
If the operation LED does not light green after the equipment has been switched on and a video signal has been applied: • check the system for basic connection and operating errors before contacting service personnel. CuratOR LX3240-MR Instructions for Use, 06/2022...
6.3 Check for pixel defects Pixel defects (small bright or dark dots) can occur in LCD monitors. During the manufactur- ing process, all monitors are checked for the permitted number of defective pixels. Defective pixels cannot be corrected. CuratOR LX3240-MR Instructions for Use, 06/2022...
Locking or unlocking the OSD menu [} 28]. Control panel The control panel with the keys can be found top center on the back of the housing frame. Key assignment Mode Menu Down Enter Standby CuratOR LX3240-MR Instructions for Use, 06/2022...
To lock or unlock the OSD menu, proceed as follows: 1. Press the "Enter" key once. 2. Then press the "Down" key three times. The OSD menu is now locked or unlocked, depending on its initial state. CuratOR LX3240-MR Instructions for Use, 06/2022...
• If you switch off the monitor with the OSD menu open or switch to standby, any changes made are saved. The layout of the OSD menu is shown in the following diagram. Fig.: OSD menu layout CuratOR LX3240-MR Instructions for Use, 06/2022...
This function enables you to make any LUT settings in the "CAL Switch" function se- lectable (1) or non-selectable (0). The names of the selectable LUT settings are taken from the "CAL Switch" function. Note: An active LUT setting cannot be re- placed. CuratOR LX3240-MR Instructions for Use, 06/2022...
The set DMPM mode is active when there is no video signal at the DP and DVI inputs. • Enabled: The backlight is turned off. • Disabled: DMPM signals are ignored. The monitor does not change to energy saving mode. CuratOR LX3240-MR Instructions for Use, 06/2022...
If the values do not differ from the de- faults, "Normal" status is displayed. Reset to Factory Defaults Selecting this function opens a dialog box where you can reset the device to the factory settings. CuratOR LX3240-MR Instructions for Use, 06/2022...
"System Mode" menu or in the "Display" -> "Input Selection" menu. Color Information Example: This function displays information on the color hues and color space. DP 1 10 bits 4:2:2 DP 2 10 bits 4:2:2 CuratOR LX3240-MR Instructions for Use, 06/2022...
• Ensure that the power supply to the monitor is not interrupted during the updates. An in- terrupted update can result in device failure. • Only use updates released by EIZO to ensure proper function of the device. • The OSD menu must be closed.
Terrain 0.5% by vol. Quartamon Med Disinfectants Perform 3% by weight Morning Mist (1:64) Terralin Protect 2% by vol. Melisepton rapid; direct Microbac Tissues Glucoprotamine Incidin Plus 8% by vol. Guanidine derivatives Lysoformin 2% by vol. CuratOR LX3240-MR Instructions for Use, 06/2022...
Page 36
Light gasoline Cleaning solvent, petroleum Petroleum ether spirit close to boiling Note Cleaning other components Information on cleaning or disinfection of other system components can be obtained from the respective instructions for use. CuratOR LX3240-MR Instructions for Use, 06/2022...
After calibration, the monitor must be visually inspected to verify successful and correct completion of the calibration procedure. Various test patterns are stored in the monitor and can be activated in the OSD; for example, Measure, Graybars, Cross, Pixel on off, Grayramp, TG18-OIQ. CuratOR LX3240-MR Instructions for Use, 06/2022...
Device is off • Switch on power switch Power cable is not inserted or incor- • Check the power cable rectly inserted. Power cable is defective • Replace power cable Blown fuse • Inform service department CuratOR LX3240-MR Instructions for Use, 06/2022...
• Inform service department Flashing No error: Update is executed. green-yel- low-red Dark LED timeout activated • No error • Switch off the LED timeout setting Operation LED is defective • Inform service department CuratOR LX3240-MR Instructions for Use, 06/2022...
LUT data is being processed. Sensor Status Normal Message after Backlight Sensor Test without error. Wrong OSD Version Error message after an attempt Use the current OSD update is made to import the wrong OSD update. CuratOR LX3240-MR Instructions for Use, 06/2022...
Vertical viewing angle Typically 178° Backlight Screen brightness 1000 cd/m² (typically, uncontrolled) 400 cd/m² (calibrated, factory setting) 10.2 Power supply Monitor CuratOR LX3240-MR Power connector 24 V DC power supply socket Line voltage DC 24 V +/-15% Current consumption max. 6 A...
Technical specifications 10.3 Inputs / outputs in the connection panel External power supply unit PSU CuratOR LX3240-MR Power connector IEC 60320 C14 appliance plug Line voltage (input) 100 V AC ... 240 V AC Line frequency (input) 47 Hz - 63 Hz Current consumption max.
10.6 Safety regulations Safety regulations Safety standards • IEC/EN 60601-1 • CAN/CSA - C 22.2 No. 60601-1 • ANSI/AAMI ES60601-1 Protection class Protection class I Degree of protection IP20 Medical device classification (EU) Class I CuratOR LX3240-MR Instructions for Use, 06/2022...
Dimension drawings 11.1 View from front, top, and below 11 Dimension drawings All dimensions in mm 11.1 View from front, top, and below CuratOR LX3240-MR Instructions for Use, 06/2022...
"On" symbol (voltage). “Off” symbol (voltage) Input for service calls. Symbol for USB. Symbol for signal input. Symbol for direct current. Symbol for "Comply with the instructions for use". “Conditionally MR safe” symbol as per IEC 62570 CuratOR LX3240-MR Instructions for Use, 06/2022...
IEC/EN 60601-1-2. Electromagnetic radiation The CuratOR LX3240-MR is intended for use in the electromagnetic environments noted below. Customers and users of the CuratOR LX3240-MR have to ensure that the device is used in such an environment. Radiation test Conformity...
Page 48
The CuratOR LX3240-MR was tested with the following compliance levels in accordance with the test requirements for professional healthcare facilities, as established in IEC/EN 6061-1-2. Customers and users of the CuratOR LX3240-MR have to ensure that the monitor is used in such an environment.
Page 49
12.2 Information on electromagnetic compatibility (EMC) Electromagnetic interference immunity The CuratOR LX3240-MR was tested with the following compliance levels in accordance with the test requirements for professional healthcare facilities, as established in IEC/EN 6061-1-2. Customers and users of the monitor have to ensure that the monitor is used in such an environment.
Page 50
Recommended minimum distance between portable or mobile RF communications devices and the CuratOR LX3240-MR The CuratOR LX3240-MR is intended for use in an electromagnetic environment in which interfer- ence due to electromagnetic radiation is controlled. For other portable and mobile RF communication devices (transmitters), the recommended minimum distance between the portable and mobile RF communication devices (transmitters) and the monitor applies as listed below.
Page 51
Recommended minimum distance between portable or mobile RF communications devices and the CuratOR LX3240-MR The CuratOR LX3240-MR is intended for use in an electromagnetic environment in which interfer- ence due to electromagnetic radiation is controlled. The customer or user of the monitor can help prevent electromagnetic interference by maintaining the recommended minimum distance between portable and mobile RF communications devices (transmitters) and the monitor.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note Use the specified cable below or EIZO signal cable with this monitor so as to keep interference within the limits of a Class B digital device. •...
EFUP shall be done in accordance with the Product Maintenance Procedures. This product must not be disposed of as unsorted municipal waste, and must be col- lected separately and handled properly after decommissioning. CuratOR LX3240-MR Instructions for Use, 06/2022...
产品中有毒有害物质或元素的名称及含量 Table of hazardous substances’ name and concentration. 12.5 Declaration of compliance with India RoHS We, EIZO Corporation, hereby declare and guarantee that this product has been designed and manufactured in compliance with the E-Waste management rule 2016 which prohibit the inclusion of the following substances except for the exemptions listed in schedule II.
12.8 Additional devices Connected devices such as PCs must meet the relevant safety standards. 12.9 Repairs Please contact the sales partner from whom you purchased the product. CuratOR LX3240-MR Instructions for Use, 06/2022...
ENERGY STAR is a registered trademark of the United States Environmental Protection Agency in the United States and other countries. EIZO, the EIZO Logo, ColorEdge, CuratOR, DuraVision, FlexScan, FORIS, RadiCS, Radi- Force, RadiNET, Raptor and ScreenManager are registered trademarks of EIZO Corpora- tion in Japan and other countries.
Need help?
Do you have a question about the CuratOR LX3240-MR and is the answer not in the manual?
Questions and answers