LS-CS-M-023
4.2.2.5
CNC brake activation
This option monitors allows an external input to activate the emergency brakes by applying 24V
to this input. During brake activation the enable and quick stop signals will remain true.
Removing 24V from this input disables the brakes immediately.
The physical connection is made to X29 as shown in
4.2.2.6
Back gauge Monitor
This option enables and monitors the back gauge output from the PCSS as shown in
below.
4-17
Figure 4-17: Option 7 Back gauge Monitor (CN3 - FIO04 Connections)
Original Language Version: 1.02
CNC Brake Activation
Figure 4-16 CNC Brake activation
Enable Monitor
Enable Output
PCSS-F Additions Technical Manual
below
Figure 4-16
FIO04 – CN7
X20
1
X21
2
X22
3
X23
4
X24
5
X25
6
X26
7
X27
8
X28
9
X29
10
X30
11
X31
12
P20
13
24VDC
14
0VDC
15
FIO04 – CN3
X00
1
X01
2
X02
3
Y04H
4
Y04L
5
Y05
6
P00
7
24VDC
8
Figure
Page 4-21