Daikin Altherma EHFH03S18D 3V Series Installer's Reference Manual page 213

Table of Contents

Advertisement

6/8
Field settings table
Breadcrumb
Field code
Setting name
A.8
[6-0E]
What is the maximum temperature setpoint?
A.8
[7-00]
--
A.8
[7-01]
--
A.8
[7-02]
How many leaving water temperature zones are there?
A.8
[7-03]
--
A.8
[7-04]
--
A.8
[7-05]
Boiler efficiency
A.8
[8-00]
Minimum running time for domestic hot water operation.
A.8
[8-01]
Maximum running time for domestic hot water operation.
A.8
[8-02]
Anti-recycling time.
A.8
[8-03]
--
A.8
[8-04]
--
A.8
[8-05]
Allow modulation of the LWT to control the room temp?
A.8
[8-06]
Leaving water temperature maximum modulation.
A.8
[8-07]
What is the desired comfort main LWT in cooling?
A.8
[8-08]
What is the desired eco main LWT in cooling?
A.8
[8-09]
What is the desired comfort main LWT in heating?
A.8
[8-0A]
What is the desired eco main LWT in heating?
A.8
[8-0B]
--
A.8
[8-0C]
--
A.8
[8-0D]
--
A.8
[8-0E]
What is the ambient temp for BUH only operation?
A.8
[9-00]
What is the maximum desired LWT for main zone in heating?
A.8
[9-01]
What is the mimimum desired LWT for main zone in heating?
A.8
[9-02]
What is the maximum desired LWT for main zone in cooling?
A.8
[9-03]
What is the mimimum desired LWT for main zone in cooling?
A.8
[9-04]
Leaving water temperature overshoot temperature.
A.8
[9-05]
What is the mimimum desired LWT for add. zone in heating?
A.8
[9-06]
What is the maximum desired LWT for add. zone in heating?
A.8
[9-07]
What is the mimimum desired LWT for add. zone in cooling?
A.8
[9-08]
What is the maximum desired LWT for add. zone in cooling?
A.8
[9-0C]
Room temperature hysteresis.
A.8
[9-0D]
Pump speed limitation
A.8
[9-0E]
Pump speed limitation additional Zone
A.8
[C-00]
--
--
A.8
[C-01]
A.8
[C-02]
Is an external backup heat source connected?
A.8
[C-03]
Bivalent activation temperature.
A.8
[C-04]
Bivalent hysteresis temperature.
A.8
[C-05]
What is the thermo request contact type for the main zone?
A.8
[C-06]
What is the thermo request contact type for the add. zone?
A.8
[C-07]
What is the unit control method in space operation?
A.8
[C-08]
Which type of external sensor is installed?
A.8
[C-09]
What is the required alarm output contact type?
A.8
[C-0A]
--
A.8
[C-0C]
--
A.8
[C-0D]
--
A.8
[C-0E]
--
A.8
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
A.8
[D-01]
Contact type of preferential kWh rate PS installation?
4P596814-1B - 2022.09
Range, step
Default value
R/W
40~60°C, step: 1°C
60°C
0
2
R/W
0: 1 LWT zone
1: 2 LWT zones
2.5
0
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
R/W
0~20 min, step: 1 min
1 min
R/W
5~95 min, step: 5 min
30 min
R/W
0~10 hour, step: 0,5 hour
0,5 hour
50
95
R/W
0: No
1: Yes
R/W
0~10°C, step: 1°C
5°C
R/W
[9-03]~[9-02], step: 1°C
18°C
R/W
[9-03]~[9-02], step: 1°C
20°C
R/W
[9-01]~[9-00]°C, step: 1°C
35°C
R/W
[9-01]~[9-00]°C, step: 1°C
33°C
13
10
16
R/W
-15~25°C, step: 1°C
-7°C
R/W
37~60°C, step: 1°C
55°C
R/W
15~37°C, step: 1°C
25°C
R/W
18~22°C, step: 1°C
22°C
R/W
5~18°C, step: 1°C
5°C
R/W
1~4°C, step: 1°C
1°C
R/W
15~37°C, step: 1°C
25°C
R/W
37~55, step: 1°C
55°C
R/W
5~18°C, step: 1°C
5°C
R/W
18~22°C, step: 1°C
22°C
R/W
1~6°C, step: 0,5°C
1°C
R/W
0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
R/W
0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
0
0
R/W
0: No
1: Bivalent
R/W
-25~25°C, step: 1°C
0°C
R/W
2~10°C, step: 1°C
3°C
R/W
0: -
1: 1 contact
2: 2 contacts
R/W
0: -
1: 1 contact
2: 2 contacts
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: Normally open
1: Normally closed
0
0
0
0
R/W
0: None
1: -
2: BUH only
3: -
R/W
0: No
1: Active open
2: Active closed
3: Safety thermostat
(*1) Only applicable for models where cooling is possible
Installer setting at variance with
default value
Date
Value
(*2) EHFH03S18D▲3V▼

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma erla03d v3 series