9
|
Electrical installation
Installer reference guide
100
Item
Remote indoor sensor
LAN adapter
for room thermostat (wired or wireless):
In case of...
Wireless room thermostat
Wired room thermostat
without multi-zoning base unit
Wired room thermostat with
multi-zoning base unit
LAN adapter – System requirements
The requirements posed on the Daikin Altherma system depend on the LAN
adapter application/system layout (app control):
Description
See:
Installation manual of the remote indoor
sensor
Addendum book for optional equipment
Wires: 2×0.75 mm²
[A.2.2.F.5]=2 (External sensor=Room
sensor)
[A.3.2.3] Ext. room sensor offset
See:
Installation manual of the LAN adapter
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²). Must be
sheathed.
Maximum length: 200 m
See
"LAN adapter – System
4
requirements" [
 100]
See...
Installation manual of the wireless room
thermostat
Addendum book for optional equipment
Installation manual of the wired room
thermostat
Addendum book for optional equipment
Installation manual of the wired room
thermostat (digital or analogue) + multi-zoning
base unit
Addendum book for optional equipment
In this case:
-
You need to connect the wired room
thermostat (digital or analogue) to the
multi-zoning base unit
-
You need to connect the multi-zoning base
unit to the outdoor unit
-
For cooling/heating operation, you also
need to implement a relay (field supply, see
addendum book for optional equipment)
ERLA03D + EHFH03S18D
Daikin Altherma 3 R F
4P596806-1C – 2022.09