  • Page 1 User reference guide Daikin Altherma – Low temperature split EHBH04+08DA EHBX04+08DA EHVH04S18DA EHVH04S23DA EHVH08S18DA EHVH08S23DA EHVX04S18DA EHVX04S23DA User reference guide EHVX08S18DA English Daikin Altherma – Low temperature split EHVX08S23DA...
  • Page 2: Table Of Contents

    8 Relocation given supervision or instruction concerning use of the appliance in Overview: Relocation ..............18 User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 3: About This Document

    Latest revisions of the supplied documentation may be available on NOTICE the regional Daikin website or via your installer. ▪ Do NOT place any objects or equipment on top of the The original documentation is written in English. All other languages unit.
  • Page 4: Components In A Typical System Layout

    The time of non- interaction differs depending on the user permission level: ▪ User or Advanced user: 15 min User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 5: Home Screen

    Room thermostat type: temperatures. Only symbols applicable for your configuration are visible on the home screen. ▪ : Daikin user interface used as room thermostat 18 Feb 2018 22:19 ▪...
  • Page 6: Setpoint Screen

    Current temperature Measured by the unit Desired temperature Turn the right dial to increase/decrease. Submenu Turn or press the left dial to go to the submenu. User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 7: Space Heating/Cooling Control

    To determine the number of temperature zones Check the number of heat emitters displayed on the home screen: If… Then… One heat emitter symbol is displayed There is only one zone. EHBH/X04+08DA + EHVH/X04+08S18+23DA User reference guide Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 8: To Change The Desired Room Temperature

    1 Go to one of the following: temperature shown on the home screen (example: 50°C). ▪ [2.1]: Main zone > Schedule ▪ [3.1]: Additional zone > Schedule User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 9: Scheduled Mode

    (example: 45°C). This ensures that a ▪ Advanced user: You can read out more information minimum amount of hot water is available at all times. Example: EHBH/X04+08DA + EHVH/X04+08S18+23DA User reference guide Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 10: To Change The User Permission Level

    1 Go to [7.4.1]: User settings > Quiet > Activation. thermostat and the LAN adapter. 2 Select Most quiet. User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 11: To Configure Time And Date

    To set the electricity price Gas price=8.58 1 Go to [7.5.1]/[7.5.2]/[7.5.3]: User settings > Electricity Calculation of the electricity price: price > High/Medium/Low. Electricity price=Actual electricity price+Incentive/kWh EHBH/X04+08DA + EHVH/X04+08S18+23DA User reference guide Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 12: Using And Programming Schedules

    Delete Edit 4.7.4 Schedule screen: Example Copy This example shows how to set a room temperature schedule in heating mode for the main zone. User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 13: Weather Dependent Operation

    ▪ Weather dependent (the leaving water temperature is determined 2 Select Edit. automatically depending on the outdoor temperature) You can change the setpoint mode for the: EHBH/X04+08DA + EHVH/X04+08S18+23DA User reference guide Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 14: Detailed Screen With Weather-Dependent Curve

    The symbol shown here corresponds to the heat emitter for that zone: ▪ : Underfloor heating ▪ : Fan coil unit ▪ : Radiator ▪ : Domestic hot water tank User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 15: Menu Structure: Overview User Settings

    Connection status User profile Operation Room Space heating/cooling Tank Setpoint screen INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EHBH/X04+08DA + EHVH/X04+08S18+23DA User reference guide Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 16: Installer Settings: Tables To Be Filled In By Installer

    NOT let the room temperature drop too low. It WARNING: FLAMMABLE MATERIAL will take more time and energy to heat up the room again. The refrigerant inside this unit is mildly flammable. User reference guide EHBH/X04+08DA + EHVH/X04+08S18+23DA Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 17: To Find The Contact/Helpdesk Number

    You see a list of the most recent malfunctions. When the heat pump fails, will appear on the user interface. EHBH/X04+08DA + EHVH/X04+08S18+23DA User reference guide Daikin Altherma – Low temperature split 4P495250-1 – 2017.12...
  • Page 18: Relocation

    When the backup heater or booster heater takes over the combined with the product according to the instructions in heat load, electricity consumption will be considerably the accompanying documentation. higher. Field supply Equipment NOT made by Daikin that can be combined with product according instructions Relocation accompanying documentation.