BEINAT GSH246 Series Manual

Household gas detector

Advertisement

Quick Links

Household gas detector
To protect your family
Using the catalytic sensor, the GSH246 detector detects the presence of explosive gas such as:
Methane and LPG, with trip sensitivity calibrated at 10% of L.E.L.
According to the CEI 216- 8 Norm of 2005, the detectors are trigged by a specific combustible
gas concentration in the environment.
The detectors should tolerate common vapours and interfering substances usually present in
household environments, and guarantee a high stability with temperature and humidity variations.
A series of technical features make this gas detector extremely versatile, reliable, accurate, and
safe.
The internal jumper makes it possible to select the relay impulse functioning, in order to connect
manual reset solenoid valves, or the continuous functioning, and to activate N.C. class "A"
solenoid valves and sirens.
The relay, free of voltage, allows installation of multiple detectors on a single solenoid valve
ensuring control of multiple dangerous environments.
The technical scheme is completed by a circuit that controls the catalytic sensor "efficiency
level",
and signals any possible fault.
These technical features make the detector ideal for civil environment safety according to
EUROPEAN REGULATIONS.
Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.
Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side
Installation and user
guide
GSH246/B
GSH246/W
CONFORMITY
Electric connections also available on
Channel: Beinat gas solutions
Belonging to
GSH246 -
V. 1
GSH900
EN 50194
EN 50270
CEI 216-8
EN 61010-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GSH246 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BEINAT GSH246 Series

  • Page 1 Standards. N.B. Refer to the documentation in all cases where the symbol is on the side CONFORMITY  EN 50194 EN 50270 CEI 216-8 Installation and user EN 61010-1 guide Electric connections also available on Channel: Beinat gas solutions...
  • Page 2 When doing the electrical connections, follow the drawing closely. Any use of the detector for purposes other than the intended one is considered improper, and as a result of which BEINAT S.r.l. therefore disclaims any responsibility for possible damages caused to people, animals or objects.
  • Page 3 Components and commands GSH246 Fault Alarm Test 1) MAINS connected indication LED. After turning on, the GSH246 performs a test of the sensor’s efficiency status, and gets it to the functioning temperature. This phase lasts about 60 seconds. At the end, the detector will issue a “BEEP”.
  • Page 4 Installation measures and positioning Indeed, the most essential factor for the proper functioning of the GSH246 is its correct installation. By following the instructions in this paragraph, high precision can be obtained together with the absence of false alarms. Install the GSH246 on the wall opposite the possible source of danger, example: kitchens, boilers, or else. Do not install: behind barriers that prevent the prompt detection of gas, near vents or fans, and in rooms where temperature falls below -10°C or over +40°C.
  • Page 5 Check that the wiring is correct and that the jumper that carries power to the relay has been set properly. All relays must be free from electrical power. Check the drawing of the connections. If other problems arise, a specialised and/or authorised technician and/or the Distributor of BEINAT S.r.l. should be contacted directly.
  • Page 6 Electrical Connections WARNING Before connecting to the mains power, ensure the voltage is correct. Carefully follow the instructions and the connections according to Regulations in force. An automatic disconnetting switch (appropriately identified as the detector sectioning device) must be incorporated in the electrical system, suitably located and easily accessible. Connection Scheme of GSH246 Detector WARNING ! All relays are free of voltage.
  • Page 7 with a normally open valve 230VAC Connection Scheme WARNING ! All relays are free of voltage. Power supply 230 V Electrovalve with a normally open valve 230VAC One or more detectors Connection 230V ac with a normally close valve 230VAC One or more detectors Connection 230V ac...
  • Page 8 Dealer Stamp Purchase Date: Registration Number : Beinat S.r.l. following the targhet to improve its products, reserves the right to modify the technical features, aesthetic and functional any time without prior notice.. BEINAT S.r.l. Via Fatebenefratelli 122/C 10077, S. Maurizio C/se (TO) - ITALY Tel.

This manual is also suitable for:

Gsh246/bGsh246/w