From a neighbor’s phone, immediately call the gas ating this or any other appliance. supplier. Follow the gas supplier’s instructions. • Always contact the Dacor Customer Service Team • If you cannot contact the gas supplier, call the fire about problems and conditions that you don’t under- department.
Do not use this appliance in combination with a sur- the cooktop. Do not allow clothing to come into con- face (countertop) ventilation system. Dacor strongly tact with the cooktop and surrounding areas during recommends the installation of a range hood in con- and immediately after use.
Use only the regulator provided. supplied to the electrical outlet according to the product • Models SGM304 and SGM365 come with a 1/2” regu- data label located on the bottom of the chassis. See lator. Model SGM466 comes with a 3/4” regulator, the Gas and Electrical Requirements table on this approved for connection to a 1/2”...
• This appliance is to be used in conjunction with a suit- * To allow clearance for hold down brackets able vent hood or approved Dacor raised vent system. • The gas supply piping, gas shut-off valve and the elec- trical outlet must be located so they do not interfere All tolerances +1/16”...
Page 8
Carefully double check all dimensions against the table below and the correct diagram before cut- ting the countertop. Countertop Dimensions Cutout Installation Type Diagram (Minimum) SGM304 without Figure 1 2 7/8” 19 3/4” 27 3/4” raised vent (Square) (7.3 cm)
Page 9
Installation Specifications Rear wall Vertical combustible surface 4 1/4" (10.8 cm) min. 7 1/2" (19.1 cm) min. from mounting surface to to combustible combustibles below side wall above cooktop chassis countertop (both sides) 1 7/8" min. (4.8 cm) Figure 1 - Square Countertop Cutout Diagram 4 1/4"...
• Grates (2 for SGM304, 3 for SGM365 and SGM466) connection. See page 4. • Burner sets (4 for SGM304, 5 for SGM365, 6 for • Do not install or use the cooktop without the included SGM466) gas regulator installed.
Installation Instructions Installing the Burner Components Verifying Proper Operation WARNING WARNING • Never attempt to operate the cooktop with any of the • Make sure that power to the electrical outlet is turned burner parts removed. off at the circuit breaker panel or fuse box and that the gas is turned off at the gas supply valve before •...
If you need service, be sure to have the model and serial numbers available when you call. See inside cover for location. Dacor is not responsible for the cost of correcting problems caused by a faulty installation.
Installation Instructions Parts List SGM466 Dacor Part Description Replacement parts may be obtained by contacting Dacor Number Customer Service. Regulator (natural gas) 62320 Dacor Customer Service Regulator (LP) 62434 Phone: (800) 793-0093 (U.S.A. and Canada) Grate 82926SB Monday — Friday 6:00 .
Need help?
Do you have a question about the SGM304 and is the answer not in the manual?
Questions and answers