Dacor SGM304 Planning Manual

Dacor SGM304 Planning Manual

30”, 36”, 46” wide, drop-in gas cooktops
Hide thumbs Also See for SGM304:

Advertisement

Document # PG04-004
All tolerances ±1/16" (±1.6 mm), unless otherwise noted.
19 1/2" *
21"
(49.5 cm)
(53.3 cm)
* including embosses/screws in side of chassis
Specifications subject to change without notice.
SGM304, SGM365, SGM466
30", 36", 46" Wide,
Drop-in Gas Cooktops
30"
(76.2 cm)
(91.4 cm)
19 1/2" *
21"
(49.5 cm)
(53.3 cm)
* including embosses in side of chassis
1 5/8" (4.1 cm)
bottom of base
to cooking surface
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
1 5/8" (4.1 cm)
bottom of base
to cooking surface
4" (10.2 cm)
chassis height
ProDUCt DIMENSIoNS -
MoDEL SGM304
27 5/8" *
(70.2 cm)
36"
(116.8 cm)
19 1/2" *
21"
(49.5 cm)
(53.3 cm)
* including embosses/screws in side of chassis
www.Dacor.com
warning
1 5/8" (4.1 cm)
bottom of base
to cooking surface
chassis height
ProDUCt DIMENSIoNS -
MoDEL SGM365
33 1/2" *
(85.1 cm)
46"
(113.3 cm)
ProDUCt DIMENSIoNS -
Revised 01/27/11 Page 1/5
PLANNING
GUIDE
4" (10.2 cm)
4" (10.2 cm)
chassis height
44 5/8" *
MoDEL SGM466
4.5
Phone: (800) 793-0093

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SGM304 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dacor SGM304

  • Page 1 SGM304, SGM365, SGM466 Document # PG04-004 Revised 01/27/11 Page 1/5 30”, 36”, 46” Wide, PLANNING Drop-in Gas Cooktops GUIDE warning • Observe all governing codes and ordinances during planning and installation. Contact your local building department for All tolerances ±1/16” (±1.6 mm), unless otherwise noted.
  • Page 2: Gas Supply Requirements

    The correct voltage, frequency and amperage must be supplied to ◊ Models SGM304 and SGM365 come with a 1/2” regulator. Model the electrical outlet according to the product data label located on the SGM466 comes with a 3/4” regulator, approved for connection to a bottom of the chassis.
  • Page 3: Cabinet And Countertop Layout

    1 7/8" min. (4.8 cm) raised Vent Compatibility See cutout dimensions If installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below: Cooktop Models approved raised Vent Models 7 1/2” (19.1 cm) min. to...
  • Page 4: Cutout Dimensions

    SGM304, SGM365, SGM466 Document # PG04-004 Revised 01/27/11 Page 4/5 30”, 36”, 46” Wide, PLANNING Gas Cooktops GUIDE Cutout Dimensions Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted iMPOrTanT: Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cutting the countertop.
  • Page 5 SGM304, SGM365, SGM466 Document # PG04-004 Revised 01/27/11 Page 5/5 30”, 36”, 46” Wide, PLANNING Gas Cooktops GUIDE Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted Rear wall Vertical combustible surface 4 1/4" (10.8 cm) min. 7 1/2" (19.1 cm) min.

This manual is also suitable for:

Sgm365Sgm466