KaVo ProXam iCam
Instructions for use

Advertisement

Table of Contents
loading

Summary of Contents for KaVo ProXam iCam

  • Page 1 KaVo ProXam iCam Instructions for use...
  • Page 2 The manufacturer, assembler and importer are responsible for the safety, reliability and performance of the unit only if: - installation, calibration, modification and repairs are carried out by qualified authorised personnel - electrical installations are carried out according to the appropriate requirements such as IEC 60364 - equipment is used according to the operating instructions.
  • Page 3: Table Of Contents

    For your safety............................6 Package contents............................9 Operating intraoral camera........................10 Placing hygienic cover on intraoral camera..................11 Intraoral camera placed in dentist element of KaVo treatment unit..........11 Intraoral camera as stand-alone version..................13 Disconnecting cable from intraoral camera.................. 15 Troubleshooting............................16 Cleaning and disinfection..........................17...
  • Page 4 Table of contents KaVo ProXam iCam Instructions for use...
  • Page 5: Introduction To Kavo Proxam Icam

    1 Introduction to KaVo ProXam iCam 1 Introduction to KaVo ProXam iCam This manual describes how to set up and use the KaVo ProXam iCam intraoral camera. The intraoral camera KaVo ProXam iCam is meant to be used together with Romexis or KaVo software (CONNECTbase, CONEXIO or TWAIN Interface).
  • Page 6 1 Introduction to KaVo ProXam iCam NOTE Any person who connects external equipment to signal input, signal output or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601-1-1. If in doubt, contact qualified technician or your local representative.
  • Page 7: Associated Documentation

    2 Associated documentation 2 Associated documentation KaVo treatment units are delivered with the following manuals: • Instructions for use For dental care professionals. Describes the treatment unit and its different parts as well as instructs how to operate and clean the treatment unit.
  • Page 8: Symbols On Product Labels

    Medical Device (Standard ISO 15223-1:2020). CE Mark Manufacturer (Standard ISO 7000). Date of manufacture (Standard ISO 7000). Serial number (Standard ISO 7000). Unique Device Identifier Type BF applied part for specified dental instruments (Standard IEC 60417). Direct current KaVo ProXam iCam Instructions for use...
  • Page 9 Consult instructions for use (Standard ISO 15223). Refer to instruction manual/booklet (Standard ISO 7010). Disposable item. Do not reuse (Standard ISO 7000). Authorized representative in the European Community Swiss authorised representative Health Industry Bar Code Instructions for use KaVo ProXam iCam...
  • Page 10: For Your Safety

    Only the supplied camera cable should be used. Using a cable other than the one supplied with the intraoral camera could cause electric shock or short-circuit. CAUTION Protect the intraoral camera and USB cable from liquids and sharp objects. KaVo ProXam iCam Instructions for use...
  • Page 11 PC simultaneously. This could cause electric shock. CAUTION Do not connect additional multiple socket-outlets or extension cord for power supply to the intraoral camera system. This could cause electric shock. Instructions for use KaVo ProXam iCam...
  • Page 12 If the intraoral camera falls, this could cause injury or product malfunction. CAUTION Do not expose to direct sunlight for a long period of time. CAUTION This equipment is not suitable for use in the presence of flammable anesthetics or oxygen. KaVo ProXam iCam Instructions for use...
  • Page 13: Package Contents

    5 Package contents 5 Package contents The package contains the following items: • 1 intraoral camera • 1 USB cable Instructions for use KaVo ProXam iCam...
  • Page 14: Operating Intraoral Camera

    4 Camera lens 5 Light source (LED) 6 USB cable Prerequisites The intraoral camera KaVo ProXam iCam can be used either with the KaVo TWAIN Interface or with Romexis software: • Option 1: KaVo TWAIN Interface The KaVo TWAIN Interface must be installed. When the TWAIN Interface is running, the intraoral camera is continuously connected to the software.
  • Page 15: Placing Hygienic Cover On Intraoral Camera

    6.2 Intraoral camera placed in dentist element of KaVo treatment unit For more detailed information on how to use the intraoral camera from the KaVo treatment unit, see the user manuals of the KaVo treatment unit, KaVo CONNECTbase and KaVo CONEXIO.
  • Page 16 (indicated by the blue indicator light on the handpiece). Interface Action Foot control Push the foot control pedal of the KaVo treatment unit short once to freeze/unfreeze the image. Handpiece Press the Image control button halfway to freeze/ unfreeze the image.
  • Page 17: Intraoral Camera As Stand-Alone Version

    6.3 Intraoral camera as stand-alone version When the intraoral camera is used as a stand-alone version, it is not connected to a KaVo treatment unit, but directly to a computer. It is operated either from the camera handpiece, from the Romexis user interface or from the KaVo TWAIN user interface.
  • Page 18 Turning off intraoral camera When you have finished working with the intraoral camera, deactivate it by pressing the Power button on the camera handpiece. When the camera is deactivated, the indicator light on the handpiece turns off. KaVo ProXam iCam Instructions for use...
  • Page 19: Disconnecting Cable From Intraoral Camera

    To disconnect the USB cable from the intraoral camera, hold the camera with one hand, press the buttons on both sides of the USB cable connector with the other hand (1) and pull the cable away from the camera (2). Instructions for use KaVo ProXam iCam...
  • Page 20: Troubleshooting

    / computer, and then turn on the treatment unit / computer and the intraoral camera (in this order). The frame is twinkling after freezing. The handpiece must be kept still when freezing an image. Retake the image. KaVo ProXam iCam Instructions for use...
  • Page 21: Cleaning And Disinfection

    Use a new hygienic cover for each patient. Reusing the hygienic cover could cause infection. Daily inspection The operator checks the handpiece, connector, and cable for damage every day. If damage is found, discontinue use and contact your local dealer. Instructions for use KaVo ProXam iCam...
  • Page 22: Service

    For further information, please visit: www.kavo.com Technical customer service The technical support for KaVo products is primarily offered by the dental supplier. KaVo provides ongoing training and special courses for dealer technicians. To guarantee constant readiness for use and maintenance of value of the KaVo products, the products must be regularly serviced.
  • Page 23: Terms And Conditions Of Warranty

    Claims from this warranty can only be asserted when the transfer form (copy) belonging to the product has been sent to KaVo, and the original can be presented by the operator or user. Instructions for use...
  • Page 24: Disposal

    Parts which can be recycled should always be taken to the appropriate processing centres, after hazardous waste has been removed. All parts and components containing hazardous materials must be disposed of in accordance with waste legislation and instructions issued by the local environmental authorities. KaVo ProXam iCam Instructions for use...
  • Page 25: Technical Specifications

    IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) +AM1(2012) or IEC60601-1:2012 +AM2(2021) or IEC60601-1:2021 EMC: EN 60601-1-2 : 2022 Max. altitude for operation Up to 3000 m Degree of protection against ingress of IPX0 water Instructions for use KaVo ProXam iCam...