Calibration Of The Vision3 Sensor Offset To The Cutting Blade - Intec ColorCut SC6500 Installation Instructions Manual

Table of Contents

Advertisement

5. If the shapes does not align, on LCD panel enter Settings and Options
menu and open 'Align Too2 to Tool1' calibration screen.
6. Using arrow bottons on key pad adjust the coordinates of the Diamond
shape:
-
Press the Up/Down arrow buttons on the key pad to move the diamond shape up
(+Y) or down (-Y).
-
Press the Left/Right arrow buttons on the key pad to move the diamond shape right
(+X) or left (-X).
7. When new settings are applied, repeat the test cut until the desired
alignment is achieved (Diamond fits inside the square).
SC6500
1.7.2

Calibration of the Vision3 sensor offset to the Cutting Blade

The ColorCut SC6500 engine includes a Vison3 sensor which is an 8th
Generation ARMS system (Automatic Registration Mark Sensor). The Vi-
sion3 sensor uses a CCD camera to automatically detect registration marks,
the position of the registration marks on your sheet allows ColorCut Pro to
compensate for any scale or skew errors and adapt cutting lines enabling
highly accurate cutting to elements printed on the media.
The Vison3 sensor is mounted offset to the cutting blade holder, so your
ColorCut Pro application must be calibrated to compensate for the offset
(distance) from the Sensor to the cutting blade.
Note: The sensor offset value is stored within the software application, so if
you plan to use multiple machines, you must set the sensor offset on each
computer therefore, if you are using ColorCut Pro Job server, on a different
computer as a production machine, you will need to set it on that machine
also in order to cut accurately.
Calibrating the Vison3 camera offset is done by the software automatically.
(It can be done manually if you want to).
To use the AutoFind feature to set the Vison3 sensor offset, use the Pen Cali-
bration Tool [A]. The pen tool is used to draw a circle, the centre of which is
used to define to point of the cutter blade, then the Vison3 ARMS sensor reads
the location of the circle and the software calculates the offset automatically.
A
B
1. Place the Calibration Pen Tool [A]. In to Tool Holder 1 [B]. (Normally the
position for the Blade Holder).
3 January 2024
1-25
Installation Procedure

Advertisement