TROUBLESHOOTING

PROBLEM
A. The sprayer does not turn on.
B. The sprayer starts but does not
draw material when the PRIME/
SPRAY knob is set to PRIME
C. The sprayer draws material but
the pressure drops when the gun
is triggered (bad spray pattern or
no spray pattern)
D. The PRIME/SPRAY knob is set to
SPRAY and there is flow through
the material return tube
E. The spray gun leaks
F. The spray tip assembly leaks
G. The spray gun will not spray
H. The spray pattern is poor (tailing)
I. The spray tip will not turn
CAUSE
1. The sprayer is not plugged in.
2. The sprayer is turned OFF (0).
3. The sprayer shuts off while under pressure.
4. No power is coming from power outlet.
5. The extension cord is damaged or is not the
proper gauge or length.
6. There is a problem with sprayer motor.
7. Spray tip clogged.
1. The inlet valve is stuck from old material.
2. There is no suction at the inlet valve.
3. The inlet filter is clogged.
4. The outlet valve is stuck or contains debris.
5. The inlet valve or outlet valve is worn or
damaged.
6. The PRIME/SPRAY valve is plugged.
1. The spray tip is worn.
2. The inlet filter is clogged.
3. The spray tip is plugged.
4. The material is too heavy or thick.
5. The material is too coarse.
6. The outlet valve assembly is damaged or worn.
7. Spray hose is too long.
1. The PRIME/SPRAY valve is dirty or worn.
1. Internal parts of spray gun are worn or dirty.
1. The tip guard nut is loose.
2. Tip guard was assembled incorrectly.
3. Tip seal is worn
1. The spray tip plugged.
2. The spray tip is in wrong position.
3. PRIME/SPRAY knob not set on SPRAY.
4. Accessory filter is dirty or plugged.
1. The spray tip is plugged.
2. The inlet filter is clogged.
3. The spray tip is worn.
4. The material is too heavy or thick.
5. Spray hose is too long.
1. High pressure has locked the spray tip in place.
SOLUTION
1. Plug the sprayer in.
2. Switch the sprayer ON (l).
3. Motor will cycle ON and OFF while spraying to
regulate pressure. This is normal.
4. Reset circuit breaker or find another outlet.
5. Refer to General Information.
6. Call Technical Service (1-800-328-8251).
7. Refer to Clear the Spray Tip.
1. Push inlet filter tab to release. If still stuck refer
to Cleaning the Inlet Valve.
2. Remove inlet filter and check suction by placing
finger on inlet valve. If no suction, refer to
Cleaning the Inlet Valve.
3. Refer to Clean the Inlet filter or replace the inlet
filter.
4. Refer to Cleaning the Outlet Valve.
5. Replace the inlet valve or outlet valve.
6. Call Technical Service (1-800-328-8251).
1. Replace spray tip with a new one.
2. Refer to Clean the Inlet filter, or replace with a
new inlet filter.
3. Refer to Clear the Spray Tip or replace with a
new spray tip.
4. Thin the material.
5. Strain the material or purchase the accessory
filter (see Accessories, page 58).
6. Replace the outlet valve.
7. Remove any extra hose length that has been
added.
1. Call Technical Service (1-800-328-8251).
1. Call Technical Service (1-800-328-8251).
1. Tighten tip guard nut.
2. Remove and assemble correctly.
3. Replace tip seal
1. Refer to Clear the Spray Tip .
2. Rotate spray tip to SPRAY position.
3. Turn PRIME/SPRAY knob to SPRAY.
4. Clean or replace.
1. Refer to Clear the Spray Tip
2. Refer to Clean the Inlet filter or replace with a
new inlet filter.
3. Replace the spray tip.
4. Thin material per manufacturer's
recommendations.
5. Remove any extra hose length that has been
added.
1. Refer to Clear the Spray Tip.
EN
19

Advertisement

Table of Contents
loading