Maintenance and Safety
IMPORTANT SAFETY INSTRUCTIONS - PLEASE DO NOT DISCARD
THESE INSTRUCTIONS
Carefully read this guide before installing the EVSE
1. This EVSE was designed to be wall-mounted or pole-mounted.
1.1. For the wall-mounted version, you must make sure the wall on which it will be
mounted is
strong enough, and that you use the appropriate type of anchors.
1.2. For the pole mounted version, you must make sure the pole on which it will be
mounted is strong enough, and that you use the appropriate type of tether straps.
Make sure with local authorities that the location where the EVSE is to be installed is
2.
free from underground pipelines or electrical equipment, otherwise you might inflict
yourself serious injuries.
Connect the power supply of the EVSE with caliber 2 to 8 copper or aluminium
3.
conductors rated for usage at a temperature of at least 75 °C.
Grounding: to ensure the safe operation of the AddÉnergie's EVSE, it must be
4.
connected to a grounding circuit compliant with local regulations and installed by a
certified electrician.
Communicate with a certified contractor, certified electrician or trained installer to
5.
ensure compliance with local building code, regulation such as ADA compliance, security
standards and weather conditions.
Any EVSE part alteration will automatically void the warranty.
6.
Handle parts with care, since they can be sharp-edged. Always use safety glasses and
7.
gloves when unpacking and installing.
Some parts are heavy and could cause injuries. Use proper lifting techniques and wear
8.
safety boots at all times during installation.
Never insert your finger into the electric vehicle connection.
9.
Never use the EVSE if the flexible power cord seems damaged or if insulation is
10.
damaged.
Never use the EVSE if the main case is broken, cracked, open or damaged.
11.
This EVSE was designed to be used with electric vehicles equipped with a SAE-J1772
12.
connector.
This EVSE is to be used to charge vehicles that do not require a ventilated
13.
environment during charging.
Replacement of the EVSE's head, gun module, gun cable, or gun must be performed by
14.
qualified service personnel.
When the case of the EVSE's head is open, all gaskets must be replaced.
15.
Do not install on or over a combustible surface.
16.
5
Need help?
Do you have a question about the SmartTWO and is the answer not in the manual?