Service life (for centrifuges according to Machinery Directive) ......23 3.6.7.3 Service life (for centrifuges according to the IVD regulation) ......24 3.6.7.4 Service life of the Sigma "Comfort" rotor coating ..........25 Safety devices ........................ 27 3.7.1 Lid lock device ......................27 3.7.2...
Page 6
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Table of contents Storage and transport ....................... 29 Dimensions and weight ....................29 Storage conditions ......................29 Notes on transport ......................29 Packaging ........................30 Transport safety device ....................30 Set-up and connection ...................... 31 Installation site ........................
Page 7
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Table of contents Malfunctions and error correction ..................49 General malfunctions ...................... 49 7.1.1 Emergency lid release ....................50 Table of error codes ......................51 Service contact ....................... 52 Maintenance and service ....................53 Maintenance ........................
Page 8
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Table of contents Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 8 / 84 Original operating manual, part no. 0700902...
→ Layout of the centrifuge Pos : 17 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /3- 16L/020 Aufbau und Wirk ungsw eise/020-0010-0010 Funkti ons- und Bedienelem ente 3- 16L @ 29\mod_1405321589340_68.docx @ 197141 @ 3 @ 1 2.1.1 Functional and operating elements User interface (see chapter 6.3.1 - "User...
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 2 Layout and mode of operation 2.1.2 Name plate Manufacturer Power consumption Max. speed Max. kinetic energy Serial number Part number Nominal voltage Type Consult operating manual 10 Symbol for special disposal (see chapter 9 - "Disposal")
Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 34 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0020 Symbol- und Hi nweis erklär ung en @ 26\mod_1405319013955_68.docx @ 191947 @ 2 @ 1 → Explanation of the symbols and notes...
Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 36 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0031 Ver antw ortung des Betrei bers IVDR @ 26\m od_1405319016560_68.docx @ 191975 @ 2 @ 1 → Responsibility of the operator The operator undertakes to authorise only trained, specialised personnel to work on the centrifuge chapter 3.4 - "Requirements concerning the...
Leerz eile @ 0\m od_1202116244500_0.doc x @ 114 @ @ 1 Pos : 45 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0020 M ec hanisc he Sic her heit (auß er 1-16/1-16K/1-7) @ 26\mod_1405319024314_68.docx @ 192059 @ 3 @ 1 →...
Leerz eile @ 0\m od_1202116244500_0.doc x @ 114 @ @ 1 Pos : 49 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0040 C hemische und bi ologisc he Sic her hei t @ 26\m od_1405319028141_68.docx @ 192101 @ 3 @ 1 →...
Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 51 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0050 Sicherheits hi nweis e z ur Z entrifug ation @ 26\mod_1405319029632_68.doc x @ 192115 @ 3 @ 1 → 3.6.5...
Safety of rotors and accessories Pos : 56 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0010 Kennz eichnung v on R otoren und Z ubehör IVD R 2er+3er @ 105\m od_1696835219772_68.docx @ 1225838 @ 4 @ 1 3.6.7.1...
Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 61 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0030 Lebens dauer Zentrifuge, Rotor en und Z ubehör IVDR - Übersc hrift @ 83\m od_1622527928369_68.docx @ 878496 @ 4 @ 1 3.6.7.3 Service life (for centrifuges according to the IVD regulation) Pos : 62 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0030 Lebens dauer IVDR - T ext @ 70\mod_1581417060258_68.doc x @ 743578 @ @ 1...
Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 64 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0040 Lebens dauer Sigma C omfort R otorbesc hic htung @ 105\m od_1695375251961_68.docx @ 1222758 @ 4 @ 1 3.6.7.4 Service life of the Sigma "Comfort"...
Page 26
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Traces of use on the black coating do not affect the anti-friction properties (see the following illustration). NOTE Fig. 7: Load-bearing bolt with traces of use – no greasing required End of the service life of the "Comfort"...
Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 79 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0080 Ver halten bei Gefahren und Unfäll en @ 27\mod_1405319051188_68.docx @ 192325 @ 2 @ 1 → Measures in the event of hazards and accidents •...
Transport safety device Pos : 94 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /3- 16L/040 Lagerung und Tr ans port/040-0051 Trans portsicherung 3- 16L_3- 16KL_3-18KS_3- 18KHS - T ext @ 36\mod_1434605535989_68.docx @ 263887 @ @ 1 The transport safety device consists of a foamed plastic piece in the rotor chamber.
Pos : 113 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0019 Ei ns etz en v on Rotor en und Zubehör ( auß er 8K)-------------------------------- @ 27\m od_1405319204492_68.docx...
Pos : 116 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0020-0022 Eins etzen eines Wi nk elrotors mit H ermetikdeck el 7,5 Nm @ 57 \mod_1527574701238_68.doc x @ 570318 @ 4 @ 1...
Pos : 118 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0020-0030 Eins etzen v on Z ubehör 4plätzig 2-16P, 2-16KL, 3- 16L, 3- 16KL, 3-18KS @ 63\mod_1554803016350_68.doc...
Control system "Spincontrol L" Pos : 125 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0011 Bedienoberfläche L ohne T emperatur anzeige @ 27\m od_1405319251981_68.docx @ 192633 @ 3 @ 1 →...
Pos : 132 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0030 U nterbr ec hen eines Brems vorgangs @ 27\m od_1405319258018_68.docx @ 192689 @ 4 @ 1...
6 Using the centrifuge Pos : 136 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0051 Dr ehzahl/RZ B ohne T emp @ 27\mod_1405319261828_68.docx @ 192731 @ 4 @ 1 →...
Page 41
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 6 Using the centrifuge Runtime as of the set speed If the runtime is to be counted as of the moment when the set speed is reached, the symbol (see the illustration) behind the set speed value must be activated: •...
Pos : 140 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0081 R otorausw ahl -ohne T em p @ 27\m od_1405319278648_68.docx @ 192815 @ 4 @ 1...
Pos : 142 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0091 Besc hleunigungs- und Bremsk urv en - ohne Tem p @ 27\m od_1405319282549_68.docx...
Pos : 146 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0111 Ak ustisc hes Signal - ohne Tem p @ 27\mod_1405319287503_68.docx @ 192899 @ 4 @ 1...
6 Using the centrifuge Pos : 148 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0121 Programms perre - ohne T emp @ 27\m od_1405319290253_68.docx @ 192927 @ 4 @ 1 6.3.2.11 Program lock ("ProgLock")
Pos : 152 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0141 Eing abes perr e - ohne T emp @ 27\mod_1405319305607_68.docx @ 192983 @ 4 @ 1...
Pos : 156 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0030- 0011 Programm speic her n - ohne T emp @ 27\m od_1405319311134_68.docx...
Pos : 158 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0030- 0021 Programm laden - ohne T em p @ 27\m od_1405319314200_68.docx @ 193067 @ 4 @ 1...
→ Malfunctions and error correction Pos : 164 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/070 Störungen und F ehl ersuche/070-0015 Allgemei ne Stör ung en_Spi ncontr ol L @ 28\m od_1405320581367_68.docx @ 194733 @ 2 @ 1 →...
Laboratory Centrifuge Sigma 3-16L IVD 7 Malfunctions and error correction Pos : 168 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/070 Störungen und F ehl ersuche/070-0020 T abell e der F ehlerm eldung en @ 28\mod_1405320582996_68.docx @ 194761 @ 2 @ 1 →...
Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 173 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080 Wartung und Instandhaltung ========================= @ 28\m od_1405320612731_68.docx @ 194789 @ 1 @ 1 → Maintenance and service The centrifuge, rotor, and accessories are subject to high mechanical stress.
8 Maintenance and service Pos : 182 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0010- 0030 Rotor, Bec her und Vi elfac htr äger ( auß er 1er Basic) @ 28\m od_1405320621063_68.docx @ 194873 @ 3 @ 1 →...
Pos : 184 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0010- 0040-0010 Trag bolz en mit C omfort R otorbesc hichtung (auß er 2-7, 2- 16P, 2-16KL) @ 90\mod_1651133147973_68.docx @ 949768 @ 4 @ 1...
Leerz eile @ 0\mod_1202116244500_0.docx @ 114 @ @ 1 Pos : 188 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0020 Sterilisati on und Desinfek tion v on Rotork ammer und Zubehör @ 28\m od_1405320626090_68.docx @ 194929 @ 2 @ 1 →...
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 192 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0030 Ins tandhaltungs arbeiten @ 28\mod_1405320628810_68.docx @ 194957 @ 2 @ 1 → Service In the event of service work that requires the removal of the panels, there is a risk of electric shock or mechanical injury.
Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 194 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0040 R ücks endung defekter T eile @ 28\mod_1405320630226_68.doc x @ 194971 @ 2 @ 1 →...
Page 61
NOTE The forms can be downloaded online from www.sigma-zentrifugen.de → [Service] → [Overhaul and repair]. Pos : 195 /010 Univ ers almodul e/ Abs chnittswec hs el @ 0\mod_1202124514062_0.docx @ 418 @ @ 1 Pos : 196 /010 Univ ers almodul e/ Seitenwechs el @ 0\mod_1202116244312_0.docx @ 105 @ @ 1...
Pos : 197 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/090 Entsorgung/090 Ents orgung================================ ===== @ 28\m od_1405320658842_68.docx @ 194985 @ 1 @ 1 → Disposal Pos : 198 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/090 Entsorgung/090-0010 Entsorgung der Z entrifuge---------------------------------------------- @ 28\m od_1405320660029_68.docx @ 194999 @ 2 @ 1 → Disposal of the centrifuge In accordance with the directive 2012/19/EU, SIGMA centrifuges are marked with the symbol shown to the left.
10 Technical data Pos : 203 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/100 T ec hnisc he D aten/100 T ec hni sche D aten - Ü bersc hrift ============================= @ 7\mod_1306745782782_68.doc x @ 43932 @ 1 @ 1 →...
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix 11.8 UKCA declaration of conformity Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 79 / 84 Original operating manual, part no. 0700902...
Page 80
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix === Ende der Liste für T extm arke Inhalt === Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 80 / 84 Original operating manual, part no. 0700902...
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index 12 Index Centrifuge decelerates during operation ..49 Centrifuge is inclined ........49 Acceleration ..........43 Centrifuge was moved during run ....49 Acceleration curves ......43, 67 Centrifuge, cleaning and care ....53 Accessories Centrifuge, service life .......
Page 82
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index Deformation of tubes (accessories) .... 58 Imbalance error .......... 51 Density ..........12, 22 Imbalance monitoring system ....27 Different service life of rotors and accessories Importance of the operating manual ..... 9 ...........
Page 83
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index Maximum number of cycles ....... 45 Quick stop ..........39 Maximum speed for tubes ......37 Quitting the modification mode ....39 Measures in the event of hazards and accidents ..........28 Radioactive substances .......
Page 84
Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index Scope of supply ......... 10 Switching the centrifuge on ......33 Selection, display, and modification of data 39 System check ..........27 Serial number ........ 12, 52, 59 System error ........49, 51 Service ............