Sigma 3-16L Operating Manual
Hide thumbs Also See for 3-16L:
Table of Contents

Advertisement

Quick Links

Original operating manual
sb
03/2014
Rev. 2.22 of 24/10/2023
Sigma 3-16L;Laboratory Centrifuge;Sigma 3-16L IVD
Laboratory Centrifuge
part no. 0700902
Sigma 3-16L
Sigma 3-16L IVD
from serial no. 146284
Laboratory Centrifuge
Operating Manual
Please retain for later use!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3-16L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sigma 3-16L

  • Page 1 Original operating manual 03/2014 Rev. 2.22 of 24/10/2023 Sigma 3-16L;Laboratory Centrifuge;Sigma 3-16L IVD Laboratory Centrifuge part no. 0700902 Sigma 3-16L Sigma 3-16L IVD from serial no. 146284 Laboratory Centrifuge Operating Manual Please retain for later use!
  • Page 2 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 2 / 84 Original operating manual, part no. 0700902...
  • Page 3 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD © Copyright by Sigma Laborzentrifugen GmbH An der Unteren Söse 50 37520 Osterode am Harz Germany Tel.: +49 (0) 5522 / 5007-0 Fax: +49 (0) 5522 / 5007-12 Web: www.sigma-zentrifugen.de E-mail: info@sigma-zentrifugen.de Version 03/2014, Rev.
  • Page 4 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 4 / 84 Original operating manual, part no. 0700902...
  • Page 5: Table Of Contents

    Service life (for centrifuges according to Machinery Directive) ......23 3.6.7.3 Service life (for centrifuges according to the IVD regulation) ......24 3.6.7.4 Service life of the Sigma "Comfort" rotor coating ..........25 Safety devices ........................ 27 3.7.1 Lid lock device ......................27 3.7.2...
  • Page 6 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Table of contents Storage and transport ....................... 29 Dimensions and weight ....................29 Storage conditions ......................29 Notes on transport ......................29 Packaging ........................30 Transport safety device ....................30 Set-up and connection ...................... 31 Installation site ........................
  • Page 7 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Table of contents Malfunctions and error correction ..................49 General malfunctions ...................... 49 7.1.1 Emergency lid release ....................50 Table of error codes ......................51 Service contact ....................... 52 Maintenance and service ....................53 Maintenance ........................
  • Page 8 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Table of contents Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 8 / 84 Original operating manual, part no. 0700902...
  • Page 9: General Information

    Leerzeil e @ 0 \mod_1202116244500_0.docx @ 114 @ @ 1 Pos : 4 /100 Sigma/100 BA Z entrifug en Sigma ( Standardm odule) /010 Allgem eine Inform ationen/010- 0021 Bestimm ungsgem äß e Verw endung IVDR ------------------------------------------- @ 26\m od_1405318952455_68.docx @ 191723 @ 2 @ 1 →...
  • Page 10: Copyright

    Laboratory Centrifuge Sigma 3-16L IVD 1 General information Pos : 8 /100 Sigma/100 BA Z entrifug en Sigma ( Standardm odule) /010 Allgem eine Inform ationen/010- 0040 Urheberrec ht Sigma ----------------------------------------------------------------- @ 26\mod_1405318956858_68.doc x @ 191751 @ 2 @ 1 →...
  • Page 11: Layout And Mode Of Operation

    → Layout of the centrifuge Pos : 17 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /3- 16L/020 Aufbau und Wirk ungsw eise/020-0010-0010 Funkti ons- und Bedienelem ente 3- 16L @ 29\mod_1405321589340_68.docx @ 197141 @ 3 @ 1 2.1.1 Functional and operating elements User interface (see chapter 6.3.1 - "User...
  • Page 12: Name Plate

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 2 Layout and mode of operation 2.1.2 Name plate Manufacturer Power consumption Max. speed Max. kinetic energy Serial number Part number Nominal voltage Type Consult operating manual 10 Symbol for special disposal (see chapter 9 - "Disposal")
  • Page 13: Mode Of Operation

    Pos : 21 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/020 Aufbau und Wirk ungsw eise/020-0020 Wirkungsweis e---------------------------------------------------------- @ 26\mod_1405318984194_68.docx @ 191807 @ 2 @ 1 → Mode of operation Pos : 22 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/020 Aufbau und Wirk ungsw eise/020-0020-0010 Prinzi p der Z entrifugati on @ 26\m od_1405318985448_68.docx @ 191821 @ 3 @ 1 → 2.2.1...
  • Page 14: Speed, Radius, And Relative Centrifugal Force

    2 Layout and mode of operation Pos : 26 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/020 Aufbau und Wirk ungsw eise/020-0020-0020- 0010 Dr ehzahl, R adius , R elativ e Zentrifugalbesc hl eunigung @ 26\mod_1405318988082_68.docx @ 191849 @ 4 @ 1 →...
  • Page 15: Safety

    Pos : 31 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030 Sic her hei t================================= ====== @ 26\m od_1405319007254_68.docx @ 191877 @ 1 @ 1 → Safety Pos : 32 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /3- 16L/030 Sic her heit/030-0012 Besc hilderung des Geräts 3-16L_3-16L IVD @ 82\m od_1621318362825_68.docx @ 871170 @ 2 @ 1 → Marking of the unit...
  • Page 16: Explanation Of The Symbols And Notes

    Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 34 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0020 Symbol- und Hi nweis erklär ung en @ 26\mod_1405319013955_68.docx @ 191947 @ 2 @ 1 → Explanation of the symbols and notes...
  • Page 17: Responsibility Of The Operator

    Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 36 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0031 Ver antw ortung des Betrei bers IVDR @ 26\m od_1405319016560_68.docx @ 191975 @ 2 @ 1 → Responsibility of the operator The operator undertakes to authorise only trained, specialised personnel to work on the centrifuge chapter 3.4 - "Requirements concerning the...
  • Page 18: Requirements Concerning The Personnel

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 38 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0041 Pers onalanforderungen IVDR @ 26\mod_1405319018891_68.docx @ 192003 @ 2 @ 1 → Requirements concerning the personnel...
  • Page 19: Informal Safety Instructions

    Pos : 39 /010 U nivers almodule/ Leerz eile @ 0\m od_1202116244500_0.doc x @ 114 @ @ 1 Pos : 40 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0050 Informelle Sic herheits hinw eise @ 26\m od_1405319019966_68.docx @ 192017 @ 2 @ 1 →...
  • Page 20: Safety Instructions

    Leerz eile @ 0\m od_1202116244500_0.doc x @ 114 @ @ 1 Pos : 45 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0020 M ec hanisc he Sic her heit (auß er 1-16/1-16K/1-7) @ 26\mod_1405319024314_68.docx @ 192059 @ 3 @ 1 →...
  • Page 21: Fire Prevention

    Leerz eile @ 0\m od_1202116244500_0.doc x @ 114 @ @ 1 Pos : 49 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0040 C hemische und bi ologisc he Sic her hei t @ 26\m od_1405319028141_68.docx @ 192101 @ 3 @ 1 →...
  • Page 22: Safety Instructions For Centrifugation

    Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 51 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0050 Sicherheits hi nweis e z ur Z entrifug ation @ 26\mod_1405319029632_68.doc x @ 192115 @ 3 @ 1 → 3.6.5...
  • Page 23: Safety Of Rotors And Accessories

    Safety of rotors and accessories Pos : 56 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0010 Kennz eichnung v on R otoren und Z ubehör IVD R 2er+3er @ 105\m od_1696835219772_68.docx @ 1225838 @ 4 @ 1 3.6.7.1...
  • Page 24: Service Life (For Centrifuges According To The Ivd Regulation)

    Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 61 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0030 Lebens dauer Zentrifuge, Rotor en und Z ubehör IVDR - Übersc hrift @ 83\m od_1622527928369_68.docx @ 878496 @ 4 @ 1 3.6.7.3 Service life (for centrifuges according to the IVD regulation) Pos : 62 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0030 Lebens dauer IVDR - T ext @ 70\mod_1581417060258_68.doc x @ 743578 @ @ 1...
  • Page 25: Service Life Of The Sigma "Comfort" Rotor Coating

    Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 64 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070- 0040 Lebens dauer Sigma C omfort R otorbesc hic htung @ 105\m od_1695375251961_68.docx @ 1222758 @ 4 @ 1 3.6.7.4 Service life of the Sigma "Comfort"...
  • Page 26 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Traces of use on the black coating do not affect the anti-friction properties (see the following illustration). NOTE Fig. 7: Load-bearing bolt with traces of use – no greasing required End of the service life of the "Comfort"...
  • Page 27: Safety Devices

    Leerz eile @ 0\m od_1202116244500_0.doc x @ 114 @ @ 1 Pos : 75 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0070-0051 U nw uchtüberwac hung Spi ncontr ol L+Easy+U nivers al @ 27\m od_1405319047031_68.docx @ 192283 @ 3 @ 1 →...
  • Page 28: Measures In The Event Of Hazards And Accidents

    Laboratory Centrifuge Sigma 3-16L IVD 3 Safety Pos : 79 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0080 Ver halten bei Gefahren und Unfäll en @ 27\mod_1405319051188_68.docx @ 192325 @ 2 @ 1 → Measures in the event of hazards and accidents •...
  • Page 29: Storage And Transport

    Storage and transport Pos : 85 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /3- 16L/040 Lagerung und Tr ans port/040-0010 Abmess ungen und Gewic ht 3- 16L, 3- 16 IVD @ 29\m od_1405321598743_68.docx @ 197169 @ 2 @ 1 →...
  • Page 30: Packaging

    Transport safety device Pos : 94 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /3- 16L/040 Lagerung und Tr ans port/040-0051 Trans portsicherung 3- 16L_3- 16KL_3-18KS_3- 18KHS - T ext @ 36\mod_1434605535989_68.docx @ 263887 @ @ 1 The transport safety device consists of a foamed plastic piece in the rotor chamber.
  • Page 31: Set-Up And Connection

    Pos : 100 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/050 Aufstellung und Ansc hluss/050-0020 Energiev ersorgung------------------------------------------------------ @ 27\m od_1405319175630_68.docx @ 192409 @ 2 @ 1 → Power supply Pos : 101 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/050 Aufstellung und Ansc hluss/050-0020- 0011 Ansc hlus sart (Kaltgerätestecker+ Schutzsc halter) @ 32\m od_1417600691402_68.docx @ 222498 @ 3 @ 1 5.2.1 Type of connection...
  • Page 32: Customer-Provided Fuses

    Leerz eile @ 0\mod_1202116244500_0.docx @ 114 @ @ 1 Pos : 103 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/050 Aufstellung und Ansc hluss/050-0020- 0020 Sic her ung en bausei ts (auß er 3-30KS, 8KS, 8KBS) @ 7\mod_1306312302397_68.docx @ 43513 @ 3 @ 1 →...
  • Page 33: Using The Centrifuge

    Leerz eile @ 0\mod_1202116244500_0.docx @ 114 @ @ 1 Pos : 111 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0010 Öffnen und Sc hließ en des Dec kels - 1 Sc hloss @ 27\m od_1405319202508_68.docx @ 192465 @ 3 @ 1 →...
  • Page 34: Installation Of Rotors And Accessories

    Pos : 113 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0019 Ei ns etz en v on Rotor en und Zubehör ( auß er 8K)-------------------------------- @ 27\m od_1405319204492_68.docx...
  • Page 35: Installation Of An Angle Rotor With A Hermetic Lid

    Pos : 116 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0020-0022 Eins etzen eines Wi nk elrotors mit H ermetikdeck el 7,5 Nm @ 57 \mod_1527574701238_68.doc x @ 570318 @ 4 @ 1...
  • Page 36: Installation Of Accessories

    Pos : 118 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0020-0030 Eins etzen v on Z ubehör 4plätzig 2-16P, 2-16KL, 3- 16L, 3- 16KL, 3-18KS @ 63\mod_1554803016350_68.doc...
  • Page 37: Adapters

    Leerz eile @ 0\mod_1202116244500_0.docx @ 114 @ @ 1 Pos : 122 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/060- 0020-0020-0050 Gefäß e ( 2-16KL bis 4-5L) @ 27\m od_1405319211622_68.docx @ 192577 @ 4 @ 1 →...
  • Page 38: Control System "Spincontrol L

    Control system "Spincontrol L" Pos : 125 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0011 Bedienoberfläche L ohne T emperatur anzeige @ 27\m od_1405319251981_68.docx @ 192633 @ 3 @ 1 →...
  • Page 39: Manual Mode

    Pos : 132 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0030 U nterbr ec hen eines Brems vorgangs @ 27\m od_1405319258018_68.docx @ 192689 @ 4 @ 1...
  • Page 40: Speed / Relative Centrifugal Force (Rcf)

    6 Using the centrifuge Pos : 136 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0051 Dr ehzahl/RZ B ohne T emp @ 27\mod_1405319261828_68.docx @ 192731 @ 4 @ 1 →...
  • Page 41 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 6 Using the centrifuge Runtime as of the set speed If the runtime is to be counted as of the moment when the set speed is reached, the symbol (see the illustration) behind the set speed value must be activated: •...
  • Page 42: Rotor Selection

    Pos : 140 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0081 R otorausw ahl -ohne T em p @ 27\m od_1405319278648_68.docx @ 192815 @ 4 @ 1...
  • Page 43: Acceleration And Deceleration Curves

    Pos : 142 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0091 Besc hleunigungs- und Bremsk urv en - ohne Tem p @ 27\m od_1405319282549_68.docx...
  • Page 44: Automatic Lid Opening Function ("Autoopen")

    Pos : 146 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0111 Ak ustisc hes Signal - ohne Tem p @ 27\mod_1405319287503_68.docx @ 192899 @ 4 @ 1...
  • Page 45: Program Lock ("Proglock")

    6 Using the centrifuge Pos : 148 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0121 Programms perre - ohne T emp @ 27\m od_1405319290253_68.docx @ 192927 @ 4 @ 1 6.3.2.11 Program lock ("ProgLock")
  • Page 46: 6.3.2.13 Input Lock

    Pos : 152 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0020- 0141 Eing abes perr e - ohne T emp @ 27\mod_1405319305607_68.docx @ 192983 @ 4 @ 1...
  • Page 47: Program Mode

    Pos : 156 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0030- 0011 Programm speic her n - ohne T emp @ 27\m od_1405319311134_68.docx...
  • Page 48: Loading A Program

    Pos : 158 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/060 Betrieb_Spi nc ontr ol L+S/Spinc ontrol L (Z ent6) /060- 0030-0030- 0021 Programm laden - ohne T em p @ 27\m od_1405319314200_68.docx @ 193067 @ 4 @ 1...
  • Page 49: Malfunctions And Error Correction

    → Malfunctions and error correction Pos : 164 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/070 Störungen und F ehl ersuche/070-0015 Allgemei ne Stör ung en_Spi ncontr ol L @ 28\m od_1405320581367_68.docx @ 194733 @ 2 @ 1 →...
  • Page 50: Emergency Lid Release

    Laboratory Centrifuge Sigma 3-16L IVD 7 Malfunctions and error correction Pos : 166 /100 Sigma/110 BA Z entrifugen Sigma (Proj ekte)/3-16L/070 Störungen und F ehl ersuche/070- 0010- 0010 N otentriegel ung 3-16L @ 29\m od_1405321641164_68.docx @ 197281 @ 3 @ 1 7.1.1...
  • Page 51: Table Of Error Codes

    Laboratory Centrifuge Sigma 3-16L IVD 7 Malfunctions and error correction Pos : 168 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/070 Störungen und F ehl ersuche/070-0020 T abell e der F ehlerm eldung en @ 28\mod_1405320582996_68.docx @ 194761 @ 2 @ 1 →...
  • Page 52: Service Contact

    Laboratory Centrifuge Sigma 3-16L IVD 7 Malfunctions and error correction Pos : 170 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/070 Störungen und F ehl ersuche/070-0030 Kontak t im Servic efall @ 28\m od_1405320584361_68.docx @ 194775 @ 2 @ 1 →...
  • Page 53: Maintenance And Service

    Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 173 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080 Wartung und Instandhaltung ========================= @ 28\m od_1405320612731_68.docx @ 194789 @ 1 @ 1 → Maintenance and service The centrifuge, rotor, and accessories are subject to high mechanical stress.
  • Page 54: Accessories

    Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 178 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0010- 0020 Zubehör (auß er 8K) @ 28\m od_1405320618247_68.docx @ 194845 @ 3 @ 1 →...
  • Page 55: Rotors, Buckets And Carriers

    8 Maintenance and service Pos : 182 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0010- 0030 Rotor, Bec her und Vi elfac htr äger ( auß er 1er Basic) @ 28\m od_1405320621063_68.docx @ 194873 @ 3 @ 1 →...
  • Page 56: Load Bearing Bolts

    Pos : 184 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0010- 0040-0010 Trag bolz en mit C omfort R otorbesc hichtung (auß er 2-7, 2- 16P, 2-16KL) @ 90\mod_1651133147973_68.docx @ 949768 @ 4 @ 1...
  • Page 57: Glass Breakage

    Leerz eile @ 0\mod_1202116244500_0.docx @ 114 @ @ 1 Pos : 188 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0020 Sterilisati on und Desinfek tion v on Rotork ammer und Zubehör @ 28\m od_1405320626090_68.docx @ 194929 @ 2 @ 1 →...
  • Page 58: Autoclaving

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 190 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0020- 0010 Autoklavi eren @ 28\mod_1405320627440_68.doc x @ 194943 @ 3 @ 1 → 8.2.1...
  • Page 59: Service

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 192 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0030 Ins tandhaltungs arbeiten @ 28\mod_1405320628810_68.docx @ 194957 @ 2 @ 1 → Service In the event of service work that requires the removal of the panels, there is a risk of electric shock or mechanical injury.
  • Page 60: Return Of Defective Centrifuges Or Parts

    Laboratory Centrifuge Sigma 3-16L IVD 8 Maintenance and service Pos : 194 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/080 War tung und Instandhaltung/080-0040 R ücks endung defekter T eile @ 28\mod_1405320630226_68.doc x @ 194971 @ 2 @ 1 →...
  • Page 61 NOTE The forms can be downloaded online from www.sigma-zentrifugen.de → [Service] → [Overhaul and repair]. Pos : 195 /010 Univ ers almodul e/ Abs chnittswec hs el @ 0\mod_1202124514062_0.docx @ 418 @ @ 1 Pos : 196 /010 Univ ers almodul e/ Seitenwechs el @ 0\mod_1202116244312_0.docx @ 105 @ @ 1...
  • Page 62: Disposal

    Pos : 197 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/090 Entsorgung/090 Ents orgung================================ ===== @ 28\m od_1405320658842_68.docx @ 194985 @ 1 @ 1 → Disposal Pos : 198 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/090 Entsorgung/090-0010 Entsorgung der Z entrifuge---------------------------------------------- @ 28\m od_1405320660029_68.docx @ 194999 @ 2 @ 1 → Disposal of the centrifuge In accordance with the directive 2012/19/EU, SIGMA centrifuges are marked with the symbol shown to the left.
  • Page 63: 10 Technical Data

    10 Technical data Pos : 203 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/100 T ec hnisc he D aten/100 T ec hni sche D aten - Ü bersc hrift ============================= @ 7\mod_1306745782782_68.doc x @ 43932 @ 1 @ 1 →...
  • Page 64: Ambient Conditions

    Laboratory Centrifuge Sigma 3-16L IVD 10 Technical data Pos : 206 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/100 T ec hnisc he D aten/100- 0010 Umgebungsbedi ngungen ung ekühlt (ohne 2-7) @ 28\mod_1405320680121_68.doc x @ 195041 @ 2 @ 1 10.1 Ambient conditions •...
  • Page 65: Appendix

    Pos : 211 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/110 Anhang/110 Anhang===================================== @ 28\m od_1405320699310_68.docx @ 195069 @ 1 @ 1 → 11 Appendix Pos : 212 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/110 Anhang/110-0010 Z ubehör programm (ohne T abell e) @ 7\m od_1306748655457_68.docx @ 43962 @ 2 @ 1 → 11.1...
  • Page 66: Speed-Gravitational-Field-Diagram

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Pos : 217 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/110 Anhang/110-0020 Dr ehz ahl-Sc hwer efeld-Diagr amm @ 28\m od_1405320705642_68.docx @ 195153 @ 2 @ 1 → 11.2 Speed-gravitational-field-diagram Fig.
  • Page 67: Acceleration And Deceleration Curves

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Pos : 219 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/110 Anhang/110-0030 Beschl eunigungs- und Bremsk urven Spinc ontrol L @ 28\mod_1405320707842_68.doc x @ 195167 @ 2 @ 1 → 11.3...
  • Page 68: Table Of The Service Life Of Rotors And Accessories

    Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Pos : 221 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/110 Anhang/110-0040 T abell e: Lebensdauer v on R otoren und Z ubehör MDR+ IVDR @ 82\mod_1619772655299_68.docx @ 867598 @ 2 @ 1 →...
  • Page 69: Resistance Data

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Pos : 223 /100 Sigma/100 BA Z entrifugen Sigma (Standardm odul e)/110 Anhang/110-0050 Beständigkeits tabelle @ 28\mod_1405320711439_68.doc x @ 195209 @ 2 @ 1 → 11.5 Resistance data The data refer to resistance at 20°C.
  • Page 70 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix - no data 1 resistant 2 practically resistant 3 partially resistant 4 not resistant Medium Formula Chromic acid Chromic potassium KCr(SO saturated sulphate Citric acid Citric acid Copper sulphate...
  • Page 71 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix - no data 1 resistant 2 practically resistant 3 partially resistant 4 not resistant Medium Formula Isopropyl alcohol Lactic acid Magnesium chloride MgCl Mercuric chloride HgCl Mercury Methyl acetate...
  • Page 72 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix - no data 1 resistant 2 practically resistant 3 partially resistant 4 not resistant Medium Formula Sodium bisulphite NaHSO Sodium carbonate Sodium chloride NaCl Sodium hydroxide NaOH Sodium hydroxide...
  • Page 73: Ec Declaration Of Conformity

    Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Pos : 225 /100 Sigma/110 BA Z entrifugen Sigma (Proj ekte)/3-16L/110 Anhang/110-0060 Konformitäts erklär ung 3- 16L, 3-16L IVDR @ 29\mod_1405321664076_68.doc x @ 197337 @ 2 @ 1 11.6 EC declaration of conformity Version 03/2014, Rev.
  • Page 74 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 74 / 84 Original operating manual, part no. 0700902...
  • Page 75 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 75 / 84 Original operating manual, part no. 0700902...
  • Page 76 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 76 / 84 Original operating manual, part no. 0700902...
  • Page 77: Declaration Of Conformity - China Rohs 2

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Declaration of conformity – China RoHS 2 11.7 Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 77 / 84 Original operating manual, part no. 0700902...
  • Page 78 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 78 / 84 Original operating manual, part no. 0700902...
  • Page 79: Ukca Declaration Of Conformity

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix 11.8 UKCA declaration of conformity Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 79 / 84 Original operating manual, part no. 0700902...
  • Page 80 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD 11 Appendix === Ende der Liste für T extm arke Inhalt === Version 03/2014, Rev. 2.22 of 24/10/2023 • sb 80 / 84 Original operating manual, part no. 0700902...
  • Page 81: 12 Index

    Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index 12 Index Centrifuge decelerates during operation ..49 Centrifuge is inclined ........49 Acceleration ..........43 Centrifuge was moved during run ....49 Acceleration curves ......43, 67 Centrifuge, cleaning and care ....53 Accessories Centrifuge, service life .......
  • Page 82 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index Deformation of tubes (accessories) .... 58 Imbalance error .......... 51 Density ..........12, 22 Imbalance monitoring system ....27 Different service life of rotors and accessories Importance of the operating manual ..... 9 ...........
  • Page 83 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index Maximum number of cycles ....... 45 Quick stop ..........39 Maximum speed for tubes ......37 Quitting the modification mode ....39 Measures in the event of hazards and accidents ..........28 Radioactive substances .......
  • Page 84 Laboratory Centrifuge Sigma 3-16L Laboratory Centrifuge Sigma 3-16L IVD Index Scope of supply ......... 10 Switching the centrifuge on ......33 Selection, display, and modification of data 39 System check ..........27 Serial number ........ 12, 52, 59 System error ........49, 51 Service ............

This manual is also suitable for:

3-16l ivd

Table of Contents