Available languages

Available languages

5. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.
NOTE: Testing for proper ventilation should be done with a
Manometer. Minimum: 0.2 mm (0.01"). Maximum: 16 mm (0.6").
If an Exhaust Hood Cannot be Used
The outside end of main vent should have a sweep elbow
directed downward.
305 mm minimum
(12")*
* Minimum clearance above
any accumulation of snow,
ice, or debris such as leaves
If main vent travels vertically through the roof, rather than
through wall, install a 180° sweep elbow on end of vent at least
610 mm (2 ft) above surface of roof.
The opening in wall or roof shall have a diameter 13 mm (1⁄2")
larger than vent diameter. Vent should be centered in opening.
Do not install screening over end of vent for best performance.
Multiple Dryer Venting
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 5,663 L/min (200 CFM) of
air per dryer. Large-capacity lint screens of proper design may
be used in main vent if checked and cleaned frequently. The
room where the dryers are located should have make-up air
equal to or greater than CFM of all the dryers in the room.
Back-draft dampers are available from your distributor and
should be installed in the vent of each dryer to keep exhausted
air from returning into dryers and to keep exhaust in balance
within main vent. Unobstructed return air openings are required.
Although usually each single-load dryer should have an
unobstructed outdoor air opening of 155 cm
6.5 cm
[1 in
] per 252 kcal [1,000 B.T.U.]), common make-up
2
2
air openings are also acceptable. Set up common openings so
the make-up air is distributed equally to all of the dryers. Keep
in mind that the coverage area must be increased by 33% to
account for the use of registers or louvers over the openings.
Also, make-up air openings should not be installed near the
location where exhaust vents exit the building.
Each vent should enter the main vent at an angle pointing in
the direction of the airflow. Vents entering from the opposite
side should be staggered to reduce the exhausted air from
interfering with the other vents.
610 mm minimum
(24")*
(24 in
) (based on
2
2
Air Flow
The maximum angle of each vent entering the main vent should
be no more than 30°.
Keep air openings free of dry cleaning fluid fumes. Fumes
create acids which, when drawn through the dryer heating
units, can damage dryers and items being dried.
A clean-out cover should be located on the main vent for
periodic cleaning of the vent system.
NOTE: For more dryer venting information, please refer to
Whirlpool document W10100920.
INSTALLING LEVELING LEGS
INSTALLING LEVELING LEGS
AND COIN BOX
AND COIN BOX
The console houses the electronic control board. The board is
factory set for a dry time of 30 minutes. Consult the tech sheet
found inside the dryer toe panel to reset dry time and for other
options.
The card reading mechanism is not included, but is available
from your usual industry sources.
1. Prepare dryer for leveling legs
NOTE:
Slide dryer onto cardboard or hardboard before moving
to avoid damaging floor covering.
Using two or more people, move dryer to desired installation
location.
Take tape off front corners of dryer. Open dryer and remove
the literature and parts packages. Wipe drum interior with a
damp cloth to remove any dust.
Take two cardboard corners from the dryer carton and place
them on the floor in back of the dryer. Firmly grasp the body of
the dryer and gently lay it on its back on the cardboard corners.
Disconnect power before making electrical connections.