Safety Precautions for Refrigerant
● To realize the function of the air conditioner unit, a special
refrigerant circulates in the system. The used refrigerant is
the fluoride R32, which is specially cleaned. The refrigerant
is flammable and inodorous. Furthermore, it can leads to
explosion under certain conditions. But the flammability of
the refrigerant is very low. It can be ignited only by fire.
● Compared to common refrigerants, R32 is a nonpolluting
refrigerant with no harm to the ozonosphere. The influence
upon the greenhouse effect is also lower. R32 has got very
good thermodynamic features which lead to a really high
energy efficiency. The units therefore need a less filling.
WARNING:
● Do not use means to accelerate the defrosting process or
to clean, other than those recommended by the manufacture.
Should repair be necessary,contact your nearest authorized
Service Centre. Any repairs carried out by unqualified
personnel may be dangerous. The appliance shall be stored
in a room without continuously operating ignition sources.
(For example: open flames , an operating gas appliance or an
operating electric heater.)
● Do not pierce or burn.
● Appliance shall be installed, operated and stored in a room
with a floor area larger than Xm
● Appliance filled with flammable gas R32. For repairs,
strictly follow manufacturers instructions only. Be aware that
refrigrants not contain odour.
● Read specialists manual.
This appliance is not intended for use by persons (including
c h i l d r e n ) w i t h r e d u c e d p h y s i c a l , s e n s o r y o r m e n t a l
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Installation and Maintenance
2
.
R32: 675
This marking indicates that this product should not be
disposed with other house hold wastes. To prevent possible
harm to the environment or human health from uncontrolled
waste throughout the EU. To prevent possible harm to the
environment or human health.
From uncontrolled waste disposal, recycle it responsibly
to promote the sustainable reuse of material resources. To
return your used device, please use the return and collection
systems or contact the retailer where the product was
purchased. They can take this product for environmental safe
recycling.
If it needs to install, move or maintain the air conditioner,
please contact dealer or local service center to conduct it at
first. Air conditioner must be installed, moved or maintained
by appointed unit. Otherwise, it may cause serious damage
or personal injury or death.
Safety Operation of Flammable Refrigerant
1. Qualification requirement for installation and
maintenance man
● All the work men who are engaging in the refrigeration
system should bear the valid certification awarded by the
authoritative organization and the qualification for dealing
with the refrigeration system recognized by this industry. If it
needs other technician to maintain and repair the appliance,
they should be supervised by the person who bears the
qualification for using the flammable refrigerant.
● It can only be repaired by the method suggested by the
equipments manufacturer.
2. Installation notes
● The air conditioner is not allowed to use in a room that
has running fire (such as fire source,working coal gas ware,
operating heater).
● It is not allowed to drill hole or burn the connection pipe.
● The air conditioner must be installed in a room that is larger
than the minimum room area.
The minimum room area is shown on the nameplate or
following table a.
● Leak test is a must after installation.