Step
6. Remove electric box assy
a
Remove the screw fixing electric box assy.
① Cut off the wire binder and pull out the
indoor tube temperature sensor.
② Screw off one grounding screw.
③ Remove the wiring terminals of motor, cold plasma
b
generator and stepping motor.
④ Remove the electric box assy.
⑤ Screw off the screws that are locking each.
Rotate the electric box assy. Twist off the screws that
are locking the wire clip and loosen the power cord.
Remove the wiring terminal of power cord. Lift up the
main board and take it off.
c
Instruction:Some wiring terminal of this products is with
lock catch and other devices.The pulling method is as
below:
1.Remove the soft sheath for some terminals at first,
hold the circlip and then pull out the terminals,
2.Pull out the holder for some terminals at first(holder
is not available for some wiring terminal).hold the
connector and then pull the terminal.
118
Procedure
Grounding
Indoor tube
screw
temperature sensor
Screws
Wire binder
ATA
ATB
ATC
Power cord
Screw
ATD
ATE
Circlip
Soft sheath
Service Manual
Screw
Electric box assy
Wiring terminal
of motor
Main board
Wiring terminal
of cold plasma
generator
Wiring terminal
of stepping motor
Wire clip
Holder
Connector
Installation and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading