GREE ELECTRIC GWH07AGA-K6DNA1A/O Service Manual page 127

Hide thumbs Also See for GWH07AGA-K6DNA1A/O:
Table of Contents

Advertisement

Step
10. Remove isolation sheet
Remove the screws fixing the isolation
sheet and then remove the isolation
sheet.
11. Remove compressor
Unsolder the welding joint connecting the capillary,
valves and the outlet pipe of condenser to remove the
a
capillary. Do not block the capillary with welding slag
during unsoldering.
Remove the 2 screws fixing the gas valve and unsolder
the welding joint between the gas valve and the air-
return pipe to remove the gas valve. (NOTE: Discharge
the refrigerant completely befor unsoldering; when
unsoldering, wrap the gas valve with a wet cloth
b
completely to avoid damage to the valve caused by
high temperature).
Remove the 2 screws fixing the liquid valve and
unsolder the welding joint connecting the liquid valve to
the Y-type pipe to remove the liquid valve.
c
Unsolder pipes connecting with compressor.
Remove the 3 foot nuts on the compressor and then
d
remove the compressor.
124
Procedure
isolation sheet
Service Manual
4-way valve
cut-off valve
compressor
nuts
Installation and Maintenance

Hide quick links: