Advertisement

Quick Links

USER MANUAL
ENGLISH
Booster IP 1-4, 3-pin
V1
name
Product code: 50796
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Booster IP 1-4 3-pin V1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SHOWTEC Booster IP 1-4 3-pin V1

  • Page 1 USER MANUAL ENGLISH Booster IP 1-4, 3-pin name Product code: 50796 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2 Booster IP 1-4, 3-pin Preface Thank you for purchasing this Showtec product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
  • Page 3: Table Of Contents

    Booster IP 1-4, 3-pin Table of contents Introduction ................................3 Before Using the Product ..........................3 Intended Use ............................... 3 Product Lifespan ..............................3 Text Conventions ..............................3 Symbols and Signal Words ..........................4 Symbols on the Information Label ........................4 Safety ..................................
  • Page 4: Introduction

    After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: ● Showtec Booster IP 1-4, 3-pin ● Schuko to power pro cable (1,5 m) ● Mounting bracket (attached) ●...
  • Page 5: Symbols And Signal Words

    Booster IP 1-4, 3-pin Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs. Always follow the instructions provided in this user manual. Indicates an imminently hazardous situation which, if not avoided, will result in DANGER serious injury or death.
  • Page 6: Safety

    Booster IP 1-4, 3-pin Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. Warnings and Safety Instructions DANGER Danger for children For adult use only.
  • Page 7 Booster IP 1-4, 3-pin ● Do not connect the cables from above the connectors, if the device is installed outdoors. Make a ‘drip loop’ in the cable so that rain water cannot enter the device. Attention Power supply ● Before connecting the device to the power supply, make sure that the current, voltage and frequency match the input voltage, current and frequency specified on the information label on the device.
  • Page 8: Requirements For The User

    Booster IP 1-4, 3-pin Requirements for the User This product may be used by ordinary persons. Installation, service and maintenance shall be carried out only by instructed or skilled persons. Contact your Highlite International dealer for more information. Instructed persons have been instructed and trained by a skilled person, or are supervised by a skilled person, for specific tasks and work activities associated with the service of this product, so that they can identify risks and take precautions to avoid them.
  • Page 9: Description Of The Device

    Booster IP 1-4, 3-pin Description of the Device The Showtec Booster IP 1-4, 3-pin is a DMX/RDM splitter and booster. The housing and connectors have an IP65 rating, which also makes this device suitable for outdoor use. Front View Power Pro True connector OUT 100–...
  • Page 10: Product Specifications

    Booster IP 1-4, 3-pin Product Specifications Model: Booster IP 1-4, 3-pin Electrical: Input voltage: 100–240 V AC, 50 Hz Power consumption: Fuse: T 1 A, 250 V Physical: Dimensions: 245 x 125 x 150 mm (L x W x H) Weight: 2,45 kg Operation and control:...
  • Page 11: Installation

    Booster IP 1-4, 3-pin Installation Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property. If trussing systems are used, installation must be carried out only by instructed or skilled persons. Follow all applicable European, national and local safety regulations concerning rigging and trussing. Installation Site Requirements ●...
  • Page 12 Booster IP 1-4, 3-pin To mount the device using the included hook-and-loop straps, follow the steps below: Loosen the mounting bracket screws (17) and remove the mounting bracket (15), as shown in Fig. 07. Fig. 07 Thread the hook-and-loop straps through the strap slots (14) to attach the device to the pipe structure, as shown in Fig.
  • Page 13: Setup And Operation

    Booster IP 1-4, 3-pin Setup and Operation Warnings and Precautions Attention Connect all data cables before supplying power. Disconnect power supply before connecting or disconnecting data cables. Setup Example Fig. 09 shows a typical setup example. Fig. 09 DMX Connection DMX-512 Protocol DMX-512 is a communication protocol used to control stage lighting and effects.
  • Page 14: Dmx Cables

    Booster IP 1-4, 3-pin DMX Cables Shielded twisted-pair cables with 3-pin XLR connectors must be used for a reliable DMX connection. You can purchase DMX cables directly from your Highlite International dealer or make your own cables. If you use XLR audio cables for DMX data transmission, this may lead to signal degradation and unreliable operation of the DMX network.
  • Page 15: Power Linking Of Multiple Devices

    100–240 V: 15 devices Booster IP 1-4, 3-pin RDM Information This device supports RDM. Refer to 5.6.2. Supported RDM PIDs (Parameter IDs) for more information. RDM Details ● Responder: 29B4:0C5xxxxx ● Manufacturer's ID: Showtec ● Manufacturer Label: Showtec ● Model Description: Booster IP 1-4 ● Model ID: ●...
  • Page 16: Supported Rdm Pids (Parameter Ids)

    Booster IP 1-4, 3-pin Supported RDM PIDs (Parameter IDs) Parameter ID Value Required DISC_UNIQUE_BRANCH 0x0001 DISC_MUTE 0x0002 DISC_UN_MUTE 0x0003 SUPPORTED_PARAMETERS 0x0050 DEVICE_INFO 0x0060 DEVICE_MODEL_DESCRIPTION 0x0080 MANUFACTURER_LABEL 0x0081 DEVICE_LABEL 0x0082 SOFTWARE_VERSION_LABEL 0x00C0 DMX_START_ADDRESS 0x00F0 SENSOR_DEFINITION 0x0200 SENSOR_VALUE 0x0201 IDENTIFY_DEVICE 0x1000 Product code: 50796...
  • Page 17: Troubleshooting

    Booster IP 1-4, 3-pin Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
  • Page 18: Maintenance

    Booster IP 1-4, 3-pin Maintenance Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. Preventive Maintenance Attention Before each use, examine the device visually for any defects. Make sure that: ●...
  • Page 19: Replacing The Fuse

    Booster IP 1-4, 3-pin Replacing the Fuse DANGER Electric shock caused by short-circuit ● Do not bypass the thermostatic switch or fuses. ● For replacement use fuses of the same type and rating only. Power surges, short-circuit or incorrect electrical power supply may cause a fuse to burn out. If the fuse burns out, the device will not function anymore.
  • Page 20: Deinstallation, Transportation And Storage

    Booster IP 1-4, 3-pin Deinstallation, Transportation and Storage Instructions for Transportation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Let the device cool down before dismounting. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation and derigging of the device.
  • Page 21 Booster IP 1-4, 3-pin Product code: 50796...
  • Page 22 Booster IP 1-4, 3-pin Product code: 50796...
  • Page 23 Booster IP 1-4, 3-pin Product code: 50796...
  • Page 24 ©2023 Showtec...

This manual is also suitable for:

50796

Table of Contents