INSTALLATION INSTRUCTIONS
SITE INSTRUCTIONS
The Southern Pride Rotisserie Gas Smoker must be installed in a location that will permit the smoker to
function for its intended purpose and to allow adequate clearance for ventilation, proper cleaning, and
maintenance access.
Minimum Clearance Requirement from Combustible Material
Back......18" (457mm)
Top.......18" (457mm)
NOTE: If provision is made for service access, Service Bay Side & Back
ELECTRICAL INSTRUCTIONS
ELECTRICAL REQUIREMENTS:
120 Volts A.C., 60 Hz.,
2 wire, single phase,
15 amp wiring required.
WARNING: This appliance, when installed, must be elec-
trically grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.2, as applicable.
WARRANTY IS VOID IF UNIT IS CONNECTED TO ANY VOLTAGE OTHER THAN SPECIFIED
ABOVE AND ON NAMEPLATE.
1. Electrician must provide the conduit and wire for hookup.
2. Power is to be left OFF throughout installation.
3. Electrical Service is connected via the factory supplied power cord located on the right rear corner (when
facing the front) of the smoker.
clearance can be reduced to 2" (51mm).
Front........................48" (1219mm)
Right & Left Side..........2" (51mm)
6 of 28
Copyright 2013 by Southern Pride Distributing, LLC Volume 1
Rear View of Smoker