Download Print this page

Advertisement

Quick Links

ATTIX 965-0H/M SD XC
ATTIX 965-2H/M SD XC
Instructions for use
107413889 C (01. 2022)
WARNUNG: Dieses Gerät enthält gesundheitsgefährliche
Stäube. Entleerung und Wartung einschließlich Entfernung
des Staubbeutels dürfen nur von sachkundigen Personen
vorgenommen werden, die geeignete persönliche Schutz-
ausrüstung tragen. Nicht einschalten bevor das komplette
Filtersystem installiert und die Funktion der Volumenstrom-
kontrolle überprüft worden ist.

Advertisement

loading
Need help?

Need help?

Do you have a question about the ATTIX 965-0H/M SD XC and is the answer not in the manual?

Questions and answers

Summary of Contents for Nilfisk-Advance ATTIX 965-0H/M SD XC

  • Page 1 ATTIX 965-0H/M SD XC ATTIX 965-2H/M SD XC Instructions for use WARNUNG: Dieses Gerät enthält gesundheitsgefährliche Stäube. Entleerung und Wartung einschließlich Entfernung des Staubbeutels dürfen nur von sachkundigen Personen vorgenommen werden, die geeignete persönliche Schutz- ausrüstung tragen. Nicht einschalten bevor das komplette Filtersystem installiert und die Funktion der Volumenstrom- kontrolle überprüft worden ist.
  • Page 3 Operating instructions ........... . 13 Bedienungsanweisungen .
  • Page 5 ATTIX 9 H/M Option / Optional accessories...
  • Page 6 ATTIX 9 H/M Type P2 Option / Optional accessories...
  • Page 7 ATTIX 9 H/M Option / Optional accessories...
  • Page 8 ATTIX 9 H/M ATTIX 965-0H/M SDXC   ø27 ø27 ø32 ø32  II = ø36 ø36 ø38 ø38 ø50 ø50 ATTIX 965-2H/M SDXC ø27 ø27 ø32 ø32 ø36 ø36 ø38 ø38 ø50 ø50 Option / Optional accessories...
  • Page 9 ATTIX 9 H/M Option / Optional accessories...
  • Page 10 ATTIX 9 H/M 10 sec . Option / Optional accessories...
  • Page 11 ATTIX 9 H/M Type P2 Option / Optional accessories...
  • Page 12 ATTIX 9 H/M Option / Optional accessories...
  • Page 13: Important Safety Instructions

    1 IMPORTANT SAFETY INSTRUCTIONS Symbols used to mark instructions DANGER Danger that leads directly to serious or irreversible injuries, or even death. WARNING Danger that can lead to serious injuries or even death. CAUTION Danger that can lead to minor injuries and damage. Before starting up your machine for the first time, this instruction manual must be read through carefully.
  • Page 14 Dust Class M (IEC 60335-2-69). The dusts which belong to this class are: dusts with OEL values > 0.1 mg/m³ as well as saw dust. The machine is tested in its entirety by vacuums for this dust class. The maximum degree of permeability is 0.1% and the dis- posal must be low dust.
  • Page 15 • Do not pick up anything that is burning or smoking, such as ciga- rettes, mat ches or hot ashes. • Use extra care when cleaning on stairs. • Do not use unless filters are fitted. • If the cleaner is not working properly or has been dropped, da m- a ged, left out doors, or dropped into water, re turn it to a service center or dealer.
  • Page 16 Only applicable to UK. Please read these essential instructions These instructions have been prepared with safety and efficiency paramount. The machine operator must be trained by a suitably qualified instructor and must understand these instructions for use, and be made aware of any relevant regulations and legislation in force at the time of use.
  • Page 17 • In no circumstances should the power supply cord be wrapped around fingers or any part of the operators person. • It is recommended that the machine should be connected via a residual current circuit breaker. • Arrange the electrical parts (sockets, plugs and couplings) and lay down the extension lead so that the protection class is maintained.
  • Page 18 Maintenance Remove the plug from the socket before performing maintenance. Before using the machine make sure that the frequency and voltage shown on the rating plate correspond with the mains voltage. The machine is designed for continuous heavy work. Depending on the number of running hours – the dust filter should be renewed.
  • Page 19 Description Handle Inlet fitting „M“ Operating elements Outlet for waste air Receptacle for electrical Inlet for fresh air lead Retaining clamp Applicance switch Handle to remove „I-0-II“ * dirt tank Applicance switch with Swivel bar to remove dirt suction power control‚ tank auto-0-I“...
  • Page 20: Operation

    Operation Appliance socket * The appliance socket is only de- the vacuum cleaner and the signed for the purposes defined appliance that is to be con- in the operating instructions. The nected. connection of different appliances 2. Read the operating instructions can result in damage.
  • Page 21: Applications And Techniques

    Applications and techniques Techniques If used correctly, additional ac- Effective cleaning is achieved if cessories, suction nozzles and you follow just a few guidelines in suction hoses can enhance the combination with your own practi- cleaning action and reduce the cal experience in special fields.
  • Page 22: Further Information

    Further information Technical data ATTIX 965-0H/M SD XC 965 2H/M SD XC Voltage 220-240 Mains frequency 50/60 Fuse Power consumption 2 x 1200 2 x 1000 Connected load for appliance socket Total connected load 2400 2300 2 x 216 2 x 174 Maximum flow rate (litres/min) 2 x 3600...
  • Page 23 EU / UE / EL / EC / EE / ES / EÚ / AB / EG Declaration of Conformity Декларация за съответствие Declaração de conformidade Prohlášení o shodě Δήλωση συμμόρφωσης Deklaracja zgodności Konformitätserklärung Megfelelősségi nyilatkozat Declaratie de conformitate Overensstemmelseserklæring Izjava o sukladnosti Декларация...
  • Page 24 următoarele standarde și directive Me, Nilfisk täten vakuutamme omalla vastuulla, Мы, Nilfisk настоящим заявляем под että edellä mainittu tuote on yhdenmukainen нашу полную ответственность, что seuraavien direktiivien ja standardien вышеперечисленные mukaisesti продукция соответствует следующими директивам и стандартам. Ние, Nilfisk С настоящото декларираме на Vi Nilfisk förklarar härmed under eget своя...
  • Page 25 UK Declaration of Conformity Nilfisk Ltd Nilfisk House, Bowerbank Way Gilwilly Industrial Estate Penrith Cumbria CA11 9BQ UK Hereby declare under our sole responsibility that the Products: VAC - Commercial - Wet/Dry Description: 220-240V, 110-120V 50-60Hz, IPX4 Type: ATTIX 961-01, ATTIX 965-21 SD XC Are in compliance with the following standards: EN 60335-1:2012+A11:2014+A13:2017 EN 60335-2-69:2012...
  • Page 26 HEAD QUARTER GERMANY PERU TURKEY DENMARK UNITED ARAB EMIRATES GREECE POLAND SALES COMPANIES ARGENTINA HOLLAND UNITED KINGDOM PORTUGAL AUSTRALIA HONG KONG UNITED STATES RUSSIA AUSTRIA VIETNAM HUNGARY SINGAPORE BELGIUM Hanoi INDIA SLOVAKIA BRAZIL SOUTH AFRICA IRELAND CANADA ITALY SOUTH KOREA CHILE JAPAN CHINA...

This manual is also suitable for:

Attix 965-2h/m sd xc